Note 4) An appropriate range is from 3 to 5L/min. To prevent damage to the radiating system, do not supply a flow over the maximum flow rate of 8L/min.
PD03] for settings. x x _ _ For manufacturer setting 08h PD11 *DI5L Input device selection 5L Any input device can be assigned to the CN1-19 pin. _ _ x x Position control mode Device selection 03h Refer to table 5.10 in [Pr. PD03] for settings. x x _ _ Speed control mode Device selection 03h Refer to table 5.10 in [Pr. PD03] for settings.
Calculation of diaphragm life Example 1) Discharge rate 5l/min, when operating 8h/D (for PAX1000) 5 0.021 238 (cycles/min) = = Cycles per minute Discharge rate Discharge per cycle 1 60 = x x 1 8 (daily operating time) Reference life cycles Cycles per minute Service life 1 60 = 1 8 50,000,000 238 x x 437 days = Example 2) Discharge rate 5l/min, when operating 8h/D (for PA3000 automatically
VQ2140-5L-C8-A Example) A port, Plug 2-4-64
Body Ported Series VQ0/1000/2000 Plug Lead Unit: Flip Type Manifold Option Double check block (Separated type) VQ2000-FPG-
[mm] Bar length [mm] 160 220 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 4H/4L 4 6H/6L 6 8H/8L 8 AH/AL 10 5H/5L 3/16 7H/7L 1/4 9H/9L 5/16 BH/BL 3/8 : With piping on one side : With piping on both sides : Unrecommended piping Symbol High-voltage cable length [m] 1 1 2 2 3 3 The number of high-voltage cable holders differs depending on the high-voltage cable length.
Description Part number Remarks Bracket A ZS-38-A1 Mounting screw (M3 x 5L, 2 pcs.) Bracket B ZS-38-A2 Mounting screw (M3 x 5L, 2 pcs.) Bracket C ZS-38-A3 Mounting screw (M3 x 5L, 2 pcs.) Panel mount adapter ZS-27-C Mounting screw (M3 x 8L, 2 pcs.) Panel mount adapter + Front protective cover ZS-27-D Mounting screw (M3 x 8L, 2 pcs.)
A XLAV: Air operated, With solenoid valve J N M Port 1(P) K L Port 3(R) Solenoid valve [mm] Model J K L M N XLAV-16-2 41 18.5 8.5 2.7 3 XLAV-25-2 45.5 22.5 8.5 2.7 3 XLAV-40-2 54.5 35 8.5 2.7 3 XLAV-50-2 61 39.5 8.5 2.7 3 XLAV-63-2 80.5 44 12 4 2 XLAV-80-2 90.5 60 12 4 2 6 Aluminum High Vacuum Angle Valve Double Acting, Bellows Seal RoHS XLC Series How to Order q w e r t y u XLC 2 M9N 16
XLA XLAV/With solenoid valve J XL XL XLQ XM XY M N Port P (Pressure port) Port R (Exhaust port) DXSA K L XVD XGT CYV (mm) (mm) J K L M N J K L M N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 Model XLAV-63 XLAV-80 XLAV-100 XLAV-160 35.5 12.3 10.2 3.6 3.6 78.5 28.7 12 4 2 40.5 13.8 10.2 3.6 3.6 87 38.7 12 4 2 50.5 21.6 10.2 3.6 3.6 105.5 50.7 12 4 2 57 24.6 10.2 3.6 3.6 128.5 57.7 12 4 2 Other dimensions
XLAV/With solenoid valve J Port P (pressure port) N M K L P R Port R (exhaust port) (mm) M 3 3 3 3 4 4 L 8.5 8.5 8.5 8.5 12 12 K 13 14 23 25 29 39 J 16.5 16.5 17.5 17.5 29 29 N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 XLAV-63 XLAV-80 3 3 3 3 2 2 Other dimensions are the same as XLA. 7 Series XLC Normally Closed/Bellows Seal Air Operated Type How to Order XLC 16 F9N Switch quantity/Mounting
XLAV/With solenoid valve J Port P (pressure port) N M K L P R Port R (exhaust port) (mm) M 3 3 3 3 4 4 L 8.5 8.5 8.5 8.5 12 12 K 13 14 23 25 29 39 J 16.5 16.5 17.5 17.5 29 29 N Model XLAV-16 XLAV-25 XLAV-40 XLAV-50 XLAV-63 XLAV-80 3 3 3 3 2 2 Other dimensions are the same as XLA. 7 Series XLC Normally Closed/Bellows Seal Air Operated Type How to Order XLC 16 F9N Switch quantity/Mounting
To be arranged by the user. 6.3 Option L [Large capacity tank] 6.3.1 Option L [Large capacity tank] Large capacity tank provide you extra space volume for fluid collection of approximately 5L above high level.
Applicable auto switch Reed switch Solid state switch Bore size (mm) D-F7, D-J79 D-F7V, D-J79C D-F7W, D-J79W D-F7WV, D-F79F D-F7NTL D-F7BAL/F7BAVL D-A7, D-A80 D-A7H, D-A80H D-A73C, D-A80C D-A79W Auto switch mounting screw (M3 x 0.5 x 6.5l) Switch mounting nut BMU1-025 25, 32, 40, 50, 63 Switch mounting bracket Round head Phillips screw (M3 x 0.5 x 14l) Hexagon socket head cap screw (M3 x 0.5 x 5l
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com VQZ VQD How to Order Valve Manifold Assembly (Example) U side VQZ2150-5L Stations VQZ2250-5L VQZ2350-5L D side VV5QZ25-05C6C1 set (C kit 5 stations manifold base) VVQZ2000-10A-51 set (Blanking plate assembly) VQZ2150-5L1 set (Single solenoid part no.)
Air operated type 2 Applicable series Symbol 03 Port size Rc 3/8 Pressure 1.0MPa 0 VBA2100/2200 VBA4100/4200 04 Rc 1/2 Related products Model Description Note VBA1110/1 VBA2100/2200 VBA4100/4200 VBA4200-04 AM250-02 AM450-04, 06 AM550-06, 10 Page 4.6-1 (Best Pneumatics No.4) Mist separator AMC310-03 AMC510-06 AMC610-10 35dB or more noise reduction Exhaust cleaner Air operated type VBAT05 (5l
Note Lead wire length: 2m With mounting screws (M3 x 5L: 2 pcs.)
Mounting with bracket Mount the bracket on the body with two M3 x 5L mounting screws. Tighten the bracket mounting screws at a tightening torque of 0.5 to 0.7 Nm. Wiring Caution M3 x 5L 1. Connection and removal of sensor connector Hold the lever and connector body with two fingers and insert the connector straight into the pin until it is locked with a click sound.
Note) Fixed unit: For vacuum/Low pressure: kPA For positive pressure: MPa Lead wire with connector Lead wire length: 2 m With mounting screws (M3 x 5L: 2 pcs.) With M3 x 8L (2 pcs.)
VF VFR How to Order Valve Manifold Assembly (Example) VP7 VP4 VQZ2150-5L VQZ2250-5L VQ U side 2 3 4 5 VQZ2350-5L VQ4 VV5QZ2505C6C1 set (C kit 5 stations manifold base) VVQZ200010A-51 set (Blank plate assembly) VQZ21505L 1 set (Valve P/N single solenoid) VQZ22505L 2 set (Valve P/N double solenoid) VQZ23505L 1 set (Valve P/N 3 position) VQZ D side 1 VQD VZS Prefix mark to valves etc. to
.) *4 Fixed unit: Instantaneous flow: L/min Accumulated flow: L XY 2 outputs (NPN/PNP switching type) + Copy function Sensor connector C *1 Can switch between 1 to 5 V and 0 to 10 V *2 Can be switched to external input or copy function Option 1 Option 2 Symbol Description Nil Without lead wire Symbol Description Nil None ZS-46-5L ZS-46-A1 A1 Bracket A (Vertical mounting) L Power supply/
Mounting with brackets Mount a bracket to the using two M3 x 5L mounting screws and install on piping. The switch can be installed horizontally depending on the installation location. PSE IS Mounting screw M3 x 5L Mounting screw M3 x 5L ISG ZSM The tightening torque for bracket mounting screw should be 0.98 Nm or less.