Heater: Indicator: 418 A XLA/XLA V Series Aluminum High Vacuum Angle Valve Dimensions XLA/Air operated (b) E C D C E E Fn (KF flange) B (K flange) Fd (a) Heater (Option) (c) Auto switch (Option) H G A A (mm) A B C D Fn Fd G H E Note 1) Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 XLA-100 XLA-160 40 17 30 1 38 40 103 39 26 40 12 1 48 50 113 63 41 55 11 2 66 65 158 68 52 75 11 2 79
Flange Size: 40, Flange Type: KF(NW), Port Direction: L (w/o Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9//--(w/o Auto Switch and w/Built-in Magnet)
Flange Size: 40, Flange Type: KF(NW), Port Direction: L (w/o Indicator, Rear Flange Surface), Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: A (2pcs, Valve Open/Closed)
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire: 0.5m (Or None in the Case of No Auto Switch), Number: 2pcs, Valve Open/Closed, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Flange Size: 40, Flange Type: KF(NW), Port Direction: w/o Indicator, Rear Flange Surface, Temperature: 5 to 60°C, Version: Legacy, Auto Switch: M9//--(w/o Auto Switch and w/Built-in Magnet), Lead Wire: -, Number: -, Body Surface Treatment: -, Seal Material: -, Seal Replacement: -, X152: -, Non-standard Indicator: -
Indicator: 6 High Vacuum Angle Valve Series XLA, XLAV Dimensions (mm) 1in = 25.4mm (b) XLA/Air operated type C D E C E E Fn (KF flange) Fd (K flange) (a) (c) Heater (optional) H B G A A (mm) H 40 G 17 26 41 52 70 83 Fd Fn 30 40 55 75 87 114 D 1 1 2 2 3 3 C 38 48 66 79 100 117 E Note 1) B 103 113 158 170 196 235 A 40 50 65 70 88 90 Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 12 11 11
Indicator: 6 High Vacuum Angle Valve Series XLA, XLAV Dimensions (mm) 1in = 25.4mm (b) XLA/Air operated type C D E C E E Fn (KF flange) Fd (K flange) (a) (c) Heater (optional) H B G A A (mm) H 40 G 17 26 41 52 70 83 Fd Fn 30 40 55 75 87 114 D 1 1 2 2 3 3 C 38 48 66 79 100 117 E Note 1) B 103 113 158 170 196 235 A 40 50 65 70 88 90 Model XLA-16 XLA-25 XLA-40 XLA-50 XLA-63 XLA-80 12 11 11
30 17 44 XLA-25-2 50 121 48 27 12 40 26 44 XLA-40-2 65 171 66 39 11 55 41 67 XLA-50-2 70 185 79 46 11 75 52 72 XLA-63-2 88 212 100 55 11 87 95 70 76 XLA-80-2 90 257 117 65 11 114 110 83 104 12 XL-OMS0001-B 6.
XLA-16-2 XLA-25-2 XLA-40-2 XLA-50-2 XLA-63-2 XLA-80-2 16 25 40 50 63 80 5605150 -6 Pa(abs) 110 l/s 1 5 14 45 80 160 200 10 FKM1.310 3/s Pam -11 FKM1.310 KFNW KFNW KDN SUS316L,SUS304,FKM MPa(G) 0.40.7 3 2 0.5MPa 31 61 220 390 680 1420 cm M5 Rc1/8 kg 0.28 0.47 1.1 1.7 3.1 5.1 1 21 9 XL-OMY0001 4-2 XLA-25-2 XLA-40-2 XLA-50-2 AC90240V XL1A25-60S-1 XL1A25-60S-1 1 1 H4 AC100V 200
9-1A AS568-016V XLD50-2-9-1A AS568-016V XLD63-2-9-1A XLD80-2-9-1A Standard AS568-009V S Valve seal assembly r XGT XLD80-2-9-1A XMD XYD XLD40-2-9-1A AS568-016 XLD50-2-9-1A AS568-016 XLD63-2-9-1A AS568-009 Special CYV Note 1) List the optional seal material symbol (refer to Table 1 below) after the model number, except for the standard seal material (FKM: compound no. 1349-80, produced by Mitsubishi
Note 2) Refer to Construction of each series for the construction numbers.
2 t !0 y r !1 OPEN o e CLOSE OPEN For 200 mm wafer For 300 mm wafer XGT22 XGT31 XGT22 (200 mm wafer type) Component Parts XLA No.
An auto switch cannot be retrofitted when a magnet is not mounted on the piston part (e.g., XLA-40-2 and XLA-40H5-2).
mounting screw 2 2 2 2 2 Block mounting screw Chrome steel/Nickel plated 2 2 2 2 Chrome steel/Nickel plated Screw for mounting rail 2 2 2 2 2 Chrome steel/Nickel plated Switch mounting screw 2 2 2 2 2 Carbon steel/Nickel plated Hexagon nut 2 2 2 Hexagon socket head plug Chrome steel/Nickel plated Note 1) mark indicates strokes.
2) n = 2, 4, 6, 8 80 + 35(n2) n = 2, 4, 6, 8 90 + 35(n2) n = 2, 4, 6, 8 55 + 50(n 2) n = 2, 3, 4 75 + 50(n 2) n = 2, 4, 6, 8 80 + 50(n 2) n = 2, 4, 6, 8 90 + 50(n 2) n = 2, 4, 6, 8 Different sides D-A44C With n Same side 10 75 80 90 1 2 (Different sides and same side) With 1 85 90 95 105 15 80 D-Z7/Z80 D-Y59/Y7P D-Y7W 15 + 40 (n 2) 2 n = 2, 4, 6, 8 80 + 40 (n 4) 2 n = 4, 8, 12, 16
Top ports 2. Side mount 2. Side ports 1. Top mount 3. T-slot side mount Easy adjustment of work piece and cylinder mounting 1. Top ports 1. Auto switch mounting 4. Bottom mount 2. Side ports 2. Auto switch mounting 4. Bottom mount Auto switches can be mounted on two sides 2. Side mount 3.
[White] Blue [Black] Black [White] Switch 1 Load Switch 1 Switch 1 Relay Load Relay contact Blue [Black] Blue [Black] Brown [Red] Brown [Red] Brown [Red] Relay Black [White] Black [White] Blue [Black] Black [White] Switch 2 Switch 2 Switch 2 Blue [Black] Blue [Black] The indicator lights will light up when both switches are turned ON. 2-wire with 2 switch AND connection 2-wire with 2 switch