Series VQ4000 Base Mounted Plug-in/Plug Lead Single Unit Model Flow characteristics Response time (ms) Port size Weight (kg) Series Configuration Model 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) Standard 1 W AC Low wattage 0.5 W C [dm3/(sbar)] C [dm3/(sbar)] b CV b CV 0 5 Metal seal Single VQ41 0 0.19 20 or less 22 or less 6.2 1.5 22 or less 6.9 0.17 1.7 0.23 (0.29) 2 position 3 position 0 5 VQ41
(Conforming to DIN) Clip Without indicator light AXT100-20-1 Rated voltage With indicator light 16.8 Voltage symbol Part no. AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 13.8 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V 1. It is able to change the cylinder port between side ported and top ported.
(b) OFF ON OFF 63.4% CDT = 100 ms 100 50 100 4.00 10.00 4.00 120 84 120 3000 4000 3000 20 50 20 1 50 60 50 1 50 60 50 1 0.20 0.15 0.20 1 0.20 0.15 0.20 2 20 30 20 2 20 30 20 2 0.10 0.05 0.10 2 0.10 0.05 0.10 (2) (a) PB06 GD2 4.00 [] PB08 PG2 120 [rad/s] PB09 VG2 3000 [rad/s] PB10 VIC 20 [ms] PB29 GD2B 10.00 [] PB30 PG2B 84 [rad/s] PB31 VG2B
The straight piping length shall be 5 times (5D) or more of the piping size to satisfy and achieve the stable measurement.
The straight piping length shall be 5 times (5D) or more of the piping size to satisfy and achieve the stable measurement.
The straight piping length shall be 5 times (5D) or more of the piping size to satisfy and achieve the stable measurement.
Note) The minimum bending radius of the D sub connector cable is 20 mm. Insulation resistance Mkm, 20C (68F) 5 or more 16 44 8 SMC Connector manufacturers Fujitsu Ltd. Japan Aviation Electronics Industry, Ltd. J. S. T. Manufacturing Co., Ltd.
LOCK FREE 2(B) 5(R1) 3(R2) Circuit diagram Plug-in type Plug lead type Release valve spacer: For D side mounting 179 (Plug-in type) 133 (Plug lead type) VVQ5000-24A-1D (Plug-in type) VVQ5000-24A-5D (Plug lead type) 16 32 A VQ51 (single) valve can be used as an air release valve by combining it with a release valve spacer.
Model Weight Weight (g) VFN2000N/Flow Characteristics Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN2120N-5D-02F 260 C 3.48 3.48 b 0.25 0.25 Cv 0.85 0.85 C 4.57 4.57 b 0.17 0.17 Cv 1.06 1.06 VFN2220N-5D-02F 400 2 position Single solenoid Double solenoid How to Order VFN2 20 1 5 D N 02 F Z Thread type Solenoid Single solenoid Double solenoid 1 2 NAMUR Interface Rc (PT) G (PF
VQZ Model Weight Weight (g) VFN200N/Flow Characteristics VZ Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) VFN212N-5D-02F 240 380 VS C 2.68 2.68 b 0.40 0.40 Cv 0.72 0.72 C 5.41 5.41 b 0.31 0.31 Cv 1.38 1.38 VFN212N-5D-02F-D 2 position Single solenoid VFN Double solenoid How to Order VFN212 5 D N 02 F Z NAMUR Interface Solenoid Voltage Nil D Single solenoid Double solenoid Thread
(P980) . 20-19 20.4.4 Identification & Maintenance (I&M) . 20-20 20.4.5 Reset To Factory . 20-21 20.5 STATE TRANSITION . 20-22 20.5.1 Basic State Machine . 20-22 20.5.2 FSA state . 20-25 20.5.3 Controlword/Statusword . 20-27 20.5.3.1 Controlword . 20-27 20.5.3.2 Statusword . 20-30 20.6 CONTROL MODE . 20-36 20.6.1 Selection of control mode . 20-36 20.6.2 Control switching . 20-37 20.6.3 Profile
Auto switches are shipped together but not assembled. 6 10 16 20 25 32 6 mm 10 mm 16 mm 20 mm 25 mm 32 mm Action D Double acting Port thread type Type M5 x 0.8 Rc1/8 NPT1/8 G1/8 Bore size 6, 10, 16, 20, 25 32 32 32 Symbol Standard stroke (mm) 6, 10, 16 20, 25, 32 5, 10, 15, 20, 25, 30, 40, 50, 60 5, 10, 15, 20, 25, 30, 40, 50, 60, 70, 80, 90, 100 Nil TN TF Applicable Auto Switches/Refer
DC24V 2. 20 3. 4. 5. 6. 7. 8.
(1 bit) 145 20 10 85 15 10 Reading of internal parameters (7 words) 270 40 15 150 25 10 Operation mode selection 165 25 10 95 15 10 Commands for virtual I/O operation by serial communication 195 30 15 110 20 10 Reading of alarm history (4 words) 215 30 15 120 20 10 Clearing of alarm history 245 35 15 135 20 10 Confirmation of communication connection 165 25 10 95 15 10 The communication
(guideline) Command 2400bps 19200bps 57600bps EE 145 25 10 EU 105 20 10 AB 105 20 10 MO 245 35 15 MD 115 20 10 OE 130 20 10 Calculation Example) Number of controllers connected: 5 Required transmission commands: EE,EU, AB Communication response time ( 25 + 20 + 20 ) x 5 = 325 ms Response time (guidline) 500 450 400 Response time [ms] EE 350 EU,AB,MD,OE 300 MO 250 200 150 100 50 0 1 2 3 4
20 20 0.5 MPa 0.7 MPa 0.7 MPa 0.7 MPa 10 10 10 0 0 0 5 10 15 0 0 10 20 30 40 60 50 0 10 20 30 40 50 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] ZFC33/3B 4, 5/32" ZFC53/5B 4, 5/32" ZFC54/5D 6, 1/4" 0.3 MPa 0.3 MPa 0.3 MPa 30 30 30 0.1 MPa Pressure drop [kPa] Pressure drop [kPa] Pressure drop [kPa] 0.1 MPa 0.1 MPa 20 20 20 0.5 MPa 0.5 MPa 0.5 MPa 0.7 MPa 0.7 MPa
Holes vns 20/30/40/50 Cornbination with a ,noduta. sayle FBL :;t.ti:l Combination with a modular style AC20 Ac:t0 VHS2O VHS3O VHS4O VHS5O An nterface pad is required attached 1o a modular FRL.