Stations: 3 Stations, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 5 Stations, AB Port: 03R (3/8, Right), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: Rc, Silencer: SB (Silencer Box)
Stations: 7 Stations, AB Port: 03R (3/8, Right), Thread: Rc, Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 6 Stations, AB Port: 03R (3/8, Right), Thread: Rc, Control: E (w/Air Release Valve), PR Port: 04B (1/2, Both Sides), PR Thread: Rc, Silencer: None, Voltage: 1 (100VAC, 50/60Hz)
Stations: 1 Station, AB Port: 03R (3/8, Right), Thread: T (NPTF), Control: None, PR Port: 04B (1/2, Both Sides), PR Thread: T (NPTF)
Stations: 6 Stations, AB Port: 03R (3/8, Right), Thread: F (G), Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 4 Stations, AB Port: 03R (3/8, Right), Thread: F (G), Control: None, PR Port: 04B (1/2, Both Sides)
Stations: 2 Stations, AB Port: 03R (3/8, Right), Thread: F (G), Control: None, PR Port: 04B (1/2, Both Sides)
Q: Required fluid volume for extension (l/min) Q: Required fluid volume for retraction (l/min) D: Bore size (cm) d: Piston rod diameter (cm) : Piston speed (mm/s) Q = D __ 4 6 _ 1000 Formula (1) Q = (D d) __ 4 6 _ 1000 ..
Stations: 3 Stations, AB Port: 3/8, Right, Thread: Rc, Control: None, PR Port: 1/2, Both Sides, PR Thread: -, Silencer: -, Voltage: -
P Q R 6 6 8 24.3 26.2 16.8 18.7 S 12.8 15.2 8 Applicable tubing O.D.
Required fluid volume for extension (l/min) Required fluid volume for retraction (l/min) Bore size (cm) Piston rod diameter (cm) Piston speed (mm/s) Q: Q: D: d: : Q = D __ 4 6 _ 1000 .. Formula (1) Q = (D d) __ 4 6 _ 1000 .
+ l 2 x Rc P 4 x FD J MM FY BB D E e Air release K F MA l C Width across flats G f Air release 10 NA FT A SS NB B SS + Q + l S + Stroke FX M H ZZ + Stroke ZZ + Q + l + Stroke FZ (mm) With rod boot Stroke range (mm) Bore size (mm) l e J B BB C F GA GB M NA NB P R S FD FT FX FY FZ SS f Q B-rod C-rod B-rod C-rod 32 27 15 M10 x 1.25 25 to 1400 58 16 21 15 11 37 31 3/8 39 130 11 11 88 40 109
Stations 3 2 1 D D D D How to Order Valve 10-SV 1 1 0 0 F 5 Note) q w r e t y u i Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors q Series r Back pressure check valve Note) Available with manifold block for station additions.
4 o i q !3 e r !2 !1 u t w y CHK CHN CHM CHM CHS CH2 o !
(mm) a b (1) (1) Weight (g) D1 D2 L1 L2 P Q M1 M2 Part No.
Q H 05 1 3 5 ZM JIS Symbol Air supply port Exhaust port Vacuum port Port size connection Nozzle diameter 05 07 0.5 mm 0.7 mm 3 5 M5 x 0.8 M3 x 0.5 Specifications Ejector System Circuit 10 1.0 mm 13 1.3 mm Applicable nozzle size (mm) Supply valve P Q Supply valve and release valve 0.5, 0.7, 1.0, 1.3 Air operated valve H M 0.35 MPa 0.5 MPa Supply pressure Components Port size M3 x 0.5 M5 x
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
Area: Japan, Asia, Australia, Stations: 4 Stations, AB Port: 04Y (1/2, Bottom), Air Release Valve: E (Air Release Valve), PR Port: 04B (1/2, Both Sides), Silencer: SB (Silencer Box), Voltage: 3 (24VDC), Q: Q (CE Approval)
Area: E (Europe), Stations: 2 Stations, AB Port: 04R (1/2, Right), Air Release Valve: w/o Air Release Valve, PR Port: 04B (1/2, Both Sides), Silencer: None, Voltage: w/o Air Release Valve, Q: Q (CE Approval)