SMC Corporation of America
Elite Part Number Search
Search Results "VV5FA1-30-051-00N"

SX3000-77-1A SX5000-77-1A SX3000 SX5000 51 80.8 97 26 mm2 SX5000 (10) 30 mm2 1-6-85 Manifold Option D-sub connector (25 pins)/Cable assembly D-sub Connector Cable Assembly Terminal No. AXT100-DS25015 030 050 L Terminal no.

SX3000-77-1A SX5000-77-1A SX3000 SX5000 51 80.8 97 26 mm2 SX5000 (10) 30 mm2 1-6-85 Manifold Option D-sub connector (25 pins)/Cable assembly D-sub Connector Cable Assembly Terminal No. AXT100-DS25015 030 050 L Terminal no.

How to Order Connector Assembly For DC: SY100 30 4A For 100 VAC: SY100 30 1A Groove Cover For 200 VAC: SY100 30 2A Pin Cover Groove For other voltages of AC: SY100 30 3A DC polar indication Lever Pin Without lead wire: SY100 30 A -+ Socket Lead wire length Nil 6 10 15 20 25 30 50 (with connector and 2 of sockets only) 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Lead wire

40 50 CCW CW Stroke[mm] Origin 50mm 10 20 30 40 50 60 CCW CW Stroke[mm] Origin 50mm -50 -40 -30 -20 -10 0 CCW CW Stroke[mm] Origin 50mm -40 -30 -20 -10 0 10 CCW CW Stroke[mm] Origin 50mm -60 -50 -40 -30 -20 -10 CCW CW Stroke[mm] -25- 4.

External Connections . 30 5.1 PWR: Power supply connector . 30 5.2 MOT: Motor connector, ENC: Encoder connector . 30 5.3 SI: Serial I/O Connector . 30 (1) Connecting the teaching box . 30 (2) Connection with a PC . 31 5.4 CC-Link communication connector . 31 6.

5F () Sub Function 9.5.1 1 F0 (P.30) 2 F0 Address 9.5.1 (P.30) 3 F0 Address(0) 0 4 F0 DATA(H) 9.5.1 (P.30) 5 F0 DATA(L) 6 F0 7 F0 815 F0 H= L= 46 - 11

pilot Operating pressure range (MPa) Ambient and fluid temperature (C) Max. operating frequency (Hz) Manual override Pilot exhaust method Lubrication Mounting orientation Impact/Vibration resistance (m/s2)Note) 2 position single, double 3 position 10 3 5 3 5 3 Non-locking push type, Push-turn locking slotted type SV Common exhaust type for main and pilot valve Not required Unrestricted 150/30

Make sure to allow intervals of 15 ms or longer (30 ms is recommended) between input signals, and maintain the input state for the same period of time. 30 No.JXC-OMY0002-A -Output terminalNo. Function Description B1 OUT0 When the operation is started and DRIVE is turned OFF, a Bit no. corresponding to the number of the active step data will be output from these terminals.

Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 12.4 Controller input signal response Signal timing Check the timing of the signal from the PLC to the controller. time When power is applied,

M8 connector 50 Series SYJ7000 How to Order Connector Assembly for L and M Plug Connector How to Order M8 Connector Cable : SY100-30-4AFor DC V100-49-1: SY100-30-1AFor 100 VAC : SY100-30-2ACable length For 200 VAC 300 mm 1 : SY100-30-3AFor other voltages of AC 500 mm 2 1000 mm 3 2000 mm : SY100-30-A 4 Without lead wire 5000 mm 7 (with connector and 2 of sockets only) Lead wire length Nil

voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) Nil A Standard: DC specifications Standard: AC specifications With power saving circuit (24, 12 VDC only) SY100-30-2AFor 200 VAC: T For other voltages of AC: SY100-30-3APower saving circuit is not available in the case of W type.

Operation methods 30 8.1 Outline 30 8.2 Operation by Step No. 30 8.3 Position/speed monitor 30 8.4 Operation by numerical instruction 30 9. Memory map 31 9.1 Memory allocation 31 (1) Input Area Mapping 31 (2) Input area details 32 (3) Output area mapping 36 (4) Output area details 37 (5) Record data (request sent from PROFINET master to JXCPH controller) 41 10.

Product Outline . 15 4.1 System construction . 15 4.2 Setting Function . 16 4.3 Step data setting method . 19 4.4 Parameter setting method . 30 5. Wiring of cables / Common precautions . 33 6.

Inappropriate specifications Leave an interval of a minimum of 15 ms (recommendation is 30 ms) between input signals and maintain the state of the signal for a minimum of 15 ms (recommendation is 30 ms), because PLC processing delays and controller scanning delays can occur. 8.4 Controller input signal response Move occasionally Signal timing Check the timing of the signal from the PLC to

Note) Apparent power (VA) [Current mA] AC 3.5/50 Hz, 3/60 Hz 100 VAC: 35/50 Hz, 30/60 Hz 200 VAC: 17.5/50 Hz, 15/60 Hz Holding Surge voltage suppressor Indicator light DC: Diode, AC: ZNR DC: LED (Red), AC: Neon bulb Note) At rated voltage Made to Order Specifications (For details, refer to page 3-3-85.) 3-3-54 5 Port Solenoid Valve Body Ported Series VZ5000 Flow Characteristics/Weight Flow

Power saving circuit is not : SY100-30-A Without lead wire available in the case of W type.

LEY40#EA: 9 kg, LEY40#EB:19 kg, LEY40#EC:38 kg LEYG40#EA:7 kg, LEYG40#EB:17 kg, LEYG40#EC:36 kg 10 mm minimum Door (Lid) 30 mm minimum Controller 60 mm minimum 30 mm minimum (direct mounting) 50mm or more (DIN rail mounting) Controller Caution If the mounting surface for the controller is not flat or is uneven, excessive stress may be applied to the enclosure, which can cause failure.

150/30 Dust proof ( DIN terminal, M8 connector: IP65) Enclosure Based on IEC529 Note 1) Based on dynamic performance test, JIS B 8374-1981.