E 60 - Please contact SMC when this alarm is generated. (049) (051) (103) (109) (153) (193) (197) (198) (202) Please contact SMC when this alarm is generated. Warning Thoroughly check safety before resetting the alarm since the operation described below will be performed according to the mode immediately after the alarm is reset by RESET.

Please refer to 9.5 Data editing function" for details of the instruction code. 00h is output in abnormal conditions. *3) 10 F to 0 Address 11 F to 0 Address (always 0) 0 is always output 60 - 12 F to 0 DATA(H) The data of the executed instruction code is output.

Options 59 14.1 Actuator cable [5m or shorter] 59 14.2 Actuator cable [8 to 20m] 59 14.3 Actuator cable for with lock [5m or less] 60 14.4 Actuator cable for with lock [8 to 20m] 60 14.5 Controller Communication cable 61 14.6 Power supply plug 61 14.7 Teaching box 62 15. Alarm for Motor Control 63 15.1 Remote IO signal output for alarm group 63 15.2 Alarms and countermeasures 64 16.

Options 59 14.1 Actuator cable [5m or shorter] 59 14.2 Actuator cable [8 to 20m] 59 14.3 Actuator cable for with lock [5m or less] 60 14.4 Actuator cable for with lock [8 to 20m] 60 14.5 Controller Communication cable 61 14.6 Power supply plug 61 14.7 Teaching box 62 14.8 Noise filter set 63 15.

(Unit: %) Minimum value to Max force of the basic parameter *1) Trigger LV For the positioning operation, this value is ignored. 60 - Effective only for the pushing operation. (when the value for the Pushing force is from 1to 100). This defines the movement speed during the pushing operation.

Also, this controller should be installed with 50mm 60 - or larger spaces between each side of it and the other structures or components. It may cause a malfunction of the controller and its peripheral devices and a fire. 4.

JXC-OMU0026 (3) LIN-A / LIN-I . 59 (4) CIR-R / CIR-L / CIR-3 . 60 (5) SYN-I . 60 10. Description of operation . 61 10.1 Return to origin . 61 10.2 Positioning Operation . 62 10.3 Pushing Operation . 64 10.4 Linear interpolation . 68 10.5 Circular interpolation . 71 10.6 Speed tuning control . 75 10.7 PLC output signal response time . 77 10.8 Methods of interrupting operation . 77 11.

VV5FA5-20-051 .1 pc. VFA5120-03 .2 pcs. VFA5220-03 .2 pcs. DXT156-19-1A .1 pc.

How to Order Manifold Assembly Example (VV5FA3-30) Closed center VFA3330-02 (1 set) Double solenoid VFA3230-02 (1 set) Single solenoid VFA3130-02 (3 sets) Manifold base (5 stations) D side U side VV5FA3-30-051 Stations 1 3 2 VV5FA3-30-0511 set (Type 30, 5-station manifold base part no.) VFA3130-023 sets (Single part no.) VFA3230-021 set (Double part no.)

Manifold Type: 30 (Top Ported Common EXH), Stations: 5 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00T (NPTF, Body Ported Types)

Manifold Type: 30 (Top Ported Common EXH), Stations: 5 Stations, Passage: 1 (Type 30), Port Size: None, Thread Type: 00F (G, Body Ported Types)

Manifold Type: Top Ported Common EXH, Stations: 5 Stations, Passage: Type 30, Port Size: None, Thread Type: NPTF, Body Ported Types

Manifold Type: Top Ported Common EXH, Stations: 5 Stations, Passage: Type 30, Port Size: None, Thread Type: G, Body Ported Types