voltage suppressor With surge voltage suppressor (Non-polar type) With light/surge voltage suppressor (Non-polar type) Nil A Standard: DC specifications Standard: AC specifications With power saving circuit (24, 12 VDC only) SY100-30-2AFor 200 VAC: T For other voltages of AC: SY100-30-3APower saving circuit is not available in the case of W type.
Power saving circuit is not : SY100-30-A Without lead wire available in the case of W type.
150/30 Dust proof ( DIN terminal, M8 connector: IP65) Enclosure Based on IEC529 Note 1) Based on dynamic performance test, JIS B 8374-1981.
Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 1 3 5 VX31 -00n x 100 + 50 Solenoid Specifications VX325-00n x 160 + 60 Temperature rise (C ) (Rated voltage) Power consumption (W) (Holding) Apparent power (VA) Frequency Power source Model VX335-00n x 160 + 60 (Hz) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area
-30-24 Band Terminal conduit 8-30-25 Grommet 8-30-26 Rail 8-30-27 Connector Grommet Tie-rod Terminal conduit 8-30-28 8-30-31 8-30-29 8-30-30 8-30-32 Grommet Direct Connector This auto switch can be mounted by tie-rod with using mounting bracket.
, IDF37E-30 IDF55E-30 IDU22E-30, IDU37E-30, IDU55E-30 25 46 IDF37E-20 IDF22E-30 39 30 mA 125 10 A 60 60 IDF37E-30 IDF55E-30 148 81 50 36 IDF75E-30 133 73 IDU22E-30 151 74 200 V type IDF75E-30, IDU75E-30 15 A IDF100F 30 A IDF125F IDF150F IDF190D 50 A IDF240D IDF370D 60 60 50 46 IDU37E-30 146 122 IDU55E-30 148 55 36 IDU75E-30 166 73 70 IDF100F to 150F Dimensions [mm] A Model A B IDF100F 434
Load Weight Allowable Moment MY3A, MY3B/M1 MY3A, MY3B/m1 MY3A, MY3B/M2 MY3A, MY3B/M3 30 20 50 40 30 200 100 50 100 20 40 30 10 MY3A 3B63 MY3A 3B63 50 40 30 10 20 5 4 3 2 MY3A 3B63 10 5 4 3 MY3A 3B63 20 MY3A 3B40 MY3A 3B40 MY3A 3B40 Load weight kg 5 4 3 Moment Nm Moment Nm Moment Nm 1 2 10 MY3A 3B40 0.5 0.4 0.3 0.2 1 2 MY3A 3B25 MY3A 3B25 5 4 3 MY3A 3B25 MY3A 3B25 0.5 0.4 0.3 1
IN side, OUT side 4 10 22 20 22 30 30 50 30 75 39 75 39 Series ZFB Model ZFB100-04 ZFB100-06 ZFB200-06 ZFB200-08 ZFB300-08 ZFB300-10 6 6 8 8 10 Metric size 3/16" 20 22 20 22 30 30 75 40 100 62 ZFB101-05 ZFB101-07 ZFB201-07 ZFB301-11 ZFB401-13 1/4" 1/4" Inch size (2) 3/8" 1/2" Specifications Fluid Air/Nitrogen Negative pressure 0.5MPa 0 to 60C (Non-freezing) 30m 0.15MPa Nylon/Soft Nylon/Polyurethane
CP-L006ICP-LOHi jCP-i:015 10 5, 10, 1 5, 20 ,(25)~ 30 Tluhnlmfwrth pi~): CP-T006Ic P-TOlO lCP-T015 15 5,1 0,15, 20, (25 )~ 30 ItI Smm spacer is added to the 30mm stroke cylinder.
or less 40 or less 30 or less 30 or less 30 or less 30 or less 50 or less 65 or less 30 or less 30 or less 30 or less 30 or less 40 or less 55 or less 40 or less 45 or less 40 or less 40 or less 40 or less ON OFF ON OFF AC Response time (ms) (at the pressure of 0.5 MPa) DC 55 or less 40 or less 45 or less 30 or less 30 or less Note) Based on dynamic performance test, JIS B 8375-1981.
Example) 4 stations manifold VV3PA3-41-041-02 1 VPA344-A 3 VP300-25-1A (Blanking plate) 1 To order valves and options mounted onto the manifold at the factory, list the valve/option with an asterisk () in front of each part number.
It is necessary to set it on the PLC side according to the kind of PLC. 6.2 The recommended value of the parameter [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Lead symbol H A B H A B T Series Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para.
It is necessary to set it on the PLC side according to the kind of PLC. 6.2 The recommended value of the parameter [LEJ] LEJS40 LEJS63 LEJB40 LEJB63 Lead symbol H A B H A B T Series Lead 24 16 8 30 20 10 27 42 Parameter *1,*2 Para.
Example) 4 stations manifold VV3PA3-41-041-02 1 VPA344-A 3 VP300-25-1A (Blanking plate) 1 To order valves and options mounted onto the manifold at the factory, list the valve/option with an asterisk () in front of each part number.
Refer to page 4-18-4.) 30 or less (at 0.5 MPa) Max. operating frequency (Hz) 5 Not required (Use turbine oil Class 1 ISO VG32, if lubricated.) Non-locking push type Locking type (Slotted), Locking type (Manual) Manual override Mounting orientation Unrestricted 300/50 Shock/Vibration resistance (m/s2 )(2) Note 1) Based on dynamic performance test, JIS B 8374-1981.
Energizing solenoid should be done at least once in 30 days. None Z No.2 Precautions on connection of 24 V or more DC Grommet type should be connected as following; Red lead wire for (+) side, Black lead wire for () side respectively. With the DIN terminal, connect the positive (+) side to the connectors no. 1 terminal, and the negative () side to the no. 2 terminal.
Energizing solenoid should be done at least once in 30 days. Precautions on connection of 24 V or more DC Grommet type should be connected as following; Red lead wire for (+) side, Black lead wire for () side respectively. With the DIN terminal, connect the positive (+) side to the connectors no. 1 terminal, and the negative () side to the no. 2 terminal.
One side solenoid latching type Manual override 2-7-29 30 30 Cylinder Speed Chart Use as a guide for selection. Please confirm the actual conditions with SMC Sizing Program.
Thread type Nil 00F 00N 00T Rc Add the valve and option part number under the manifold base part number. In the case of complex arrangement, specify them on the manifold specification sheet.
-mGm-m VX VNl VQ Dotted line: Bracket mounting style (-F) 4.3-9 Series VQ20/30 Dimensions/Series VQ30 DIN connector (Y) VQ31A1-mYmm-m Dotted line: Bracket mounting style (-F) 4.3-10 Series VQ20/30 For Dry Air, Pilot Operated 2 Port Solenoid Valve How to Order Manifold VV2Q 2 2 08 How to Order Manifold Assembly List valve and option part numbers under the manifold base part number.