Actuation Type: 3 Position Closed Center, Sealant: Metal Seal, Function: Standard (1W), Voltage: 24VDC, Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: -, Port Size: -, Thread: -, Composite Symbol: -
Actuation Type: 3 Position Closed Center, Sealant: Metal Seal, Function: Standard (1W), Voltage: 24VDC, Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: IP65 Protection Compatible, 1: 1, Piping Specification: -, Port Size: -, Thread: -, Composite Symbol: -
Actuation Type: 3 Position Closed Center, Sealant: Metal Seal, Function: Standard (1W), Voltage: 12VDC, Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: IP65 Protection Compatible, 1: 1, Piping Specification: -, Port Size: -, Thread: -, Composite Symbol: -
Actuation Type: 3 Position Closed Center, Sealant: Metal Seal, Function: Standard (1W), Voltage: 220VAC 50/60HZ, Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style (Tool Required), Protection: Dust Proof, 1: 1, Piping Specification: -, Port Size: -, Thread: -, Composite Symbol: -
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal
slave modes AS-Interface (Negative common) 4 in/4 out, 31 slave modes 10 11 Side ported Bottom ported 8 in/8 out, 31 slave modes Note) Without SI unit, the symbol is nil. 4 in/4 out, 31 slave modes The SY5000 manifold base is used for the bottom ported of the SY3000.
VQ valves are ideal for applications requiring high speed, frequent operation, stable response time and long service life. Innovative mounting methods allow valves to be changed without entirely disassembling the manifold. Built-in one-touch fittings save piping time and labor. Fluid: air/inert gas, Operating pressure range: 0.10 - 1.0MPa, Effective area mm 2 (Cv): 2 position metal seal
Diameter Model No M A B C D E F G H P U Load (KN) Weight (g) Angular Deflection 32 JA30-10-125 M10X1.25 49.5 19.5 24 5 8 8 17 9 0.5 2.5 70 5 40 JA40-12-125 M12X1.25 60 20 31 6 11 11 22 13 0.75 4.4 160 5 50/63 JA50-16-150 M16X1.5 71.5 22 41 7.5 14 13.5 27 15 1 11 300 5 80/100 JAH50-20-150 M20X1.5 101 28 31 59.5 11.5 24 16 32 18 2 18 1080 5 D I M E N S I O N S A N G L E D R E A R C L E V I
31 33.5 22 54 Reference dimensions after Uni thread installation.
(inch) 2 x Applicable tubing H L1 M P 1/4 1/8 KQ2Z07-34lS 8 11.1 13.4 18.4 13.7 25.6 22.4 13.3 11.1 7.5 6.6 4.5 15.2 1/4 KQ2Z07-35lS 11.11 11.1 17.6 20.4 18 31 26.6 13.3 11.1 7.7 6.6 4.5 29.5 Fittings D1 A L2 L3 5/16 1/8 KQ2Z09-34lS 11.11 13.2 17.6 21.2 15.1 27.6 24.4 14.2 13.2 20.5 14.2 6 24.1 1/4 KQ2Z09-35lS 11.11 13.2 17.6 21.2 18.5 31 26.6 14.2 13.2 20.5 14.2 6 31 3/8 KQ2Z09-36lS 12.7
42 M5 x 0.8 4.8 9.5 M10 x 1.0 45.5 54 66 78 84 108 126 138 SA X Y Z ZA 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 100 st 101 to 125 st 126 to 150 st 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 100 st 101 to 125 st 126 to 150 st 5 to 15 st 16 to 30 st 31 to 45 st 46 to 60 st 61 to 75 st 76 to 100 st 101 to 125 st 126 to 150 st Bore size D6 34.5 (
Diameter Model No M A B C D E F G H P U Load (KN) Weight (g) Angular Deflection 32 JA30-10-125 M10X1.25 49.5 19.5 24 5 8 8 17 9 0.5 2.5 70 5 40 JA40-12-125 M12X1.25 60 20 31 6 11 11 22 13 0.75 4.4 160 5 50/63 JA50-16-150 M16X1.5 71.5 22 41 7.5 14 13.5 27 15 1 11 300 5 80/100 JAH50-20-150 M20X1.5 101 28 31 59.5 11.5 24 16 32 18 2 18 1080 5 D I M E N S I O N S A N G L E D R E A R C L E V I
The example is when a surge protector is connected. 11 31 11.
Binary Output 1 OFF OFF 2 ON OFF 31 point preset output is possible without bank switching, by means of binary system output from a 5 point output terminal.
Bit 16 to 31: Reserved (0) Binary Data Extended Address Setting (for Future Use) 4 bytes 05H 1 This is the number of extended addresses used.
Refer to the Made to Order Specifications on page 8-13-31.
Auto Switch Mounting Heights (mm) D-G5m/K59 D-G5mW/K59W D-G59F/G5BAL D-G5NTL D-B5m/B64 D-B59W CHQ D-F5m/J5m D-F5mW/J59W D-F59F/F5BAL D-F5NTL D-M9mV/M9mWV D-M9mAVL D-A9mV Bore size (mm) D-M9m/M9mW D-A9mAL D-A9m D-A5m/A6m D-A59W D-G39m/K39m D-A3m D-A44 CHKm CHN Hs Hs Ht Hs Hs Hs Ht Hs Ht Hs Ht 40 31 31 36 31 38 33.5 39.5 33.5 38 72.5 82.5 CHM 50 36.5 36.5 40 36.5 43 39 44 39 43.5 78 88 63 40
(mm) KQ2F04 to 12 Effective area (2) (mm2) Connection thread Rc (1) Mass (g) D1 D2 L1 L2 M Model Nylon Urethane Applicable tubing KQ2F04-01 KQ2F04-02 KQ2F06-01 KQ2F06-02 KQ2F06-03 KQ2F08-01 KQ2F08-02 KQ2F08-03 KQ2F10-02 KQ2F10-03 KQ2F12-02 KQ2F12-03 KQ2F12-04 KQ2F16-03 KQ2F16-04 1 8 1 4 1 8 1 4 3 8 15 23 15 22 25 17 24 24 27 30 36 31 52 59 58 10 27 31 27.5 31 33.5 29 32.5 33.5 34.5 36.5 35