Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: [Rc (R)] Rc, Port Size: 1, Pressure Rating(MPa): 02 to 0.9, Driving Type: Pilot Type
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: [Rc (R)] Rc, Port Size: 1, Pressure Rating(MPa): 02 to 0.9, Driving Type: Pilot Type
Type: Solenoid Valves, Application: Single Unit, Mounting Orientation: Direct, Voltage: DC24V, Specification: Standard / Lubrication Free, Valve Type: 3-Port Valve, Actuation: [Single] Single, Status at Power Off: Self-Recovery (Spring Return), Valve Positions: 2-Position Normally Closed, Pipe Port Type: [Rc (R)] Rc, Port Size: 1, Pressure Rating(MPa): 02 to 0.9, Driving Type: Pilot Type
Pilot valve assembly for VG342 Valve option Light/Surge voltage suppressor Standard type Nil Energy-saving type Y Nil None Continuous duty type E S With surge voltage suppressor (Grommet type is only available.)
240 V . 199 256 % 16 31 % 48 .5 13 23 60 182 0 lt1: o:~9 28 110 90 148 58 191 248 52 11 .2 66 StroKe 230 295 37 'h 55 15 23 70 208 0 <:::0 0 '073 34 1 . 14 40 h 56.5 15 25 80 226 0 25 g:r n 40 140 110 192 71 221 286 65 12 .5 80 ~ 80 162 130 214 72 235 306 65 14 .0 81 244 315 100 17 Series eLA Auto Switch Standard Specifications Reed Lead wire Oil proof vinyl , Impact resistance 300mIS (3D
voltage suppressor) 24 VAC 12 VDC 12 VDC 24 VDC Electrical option Other option Faston terminal 100 VAC 110 VAC 200 VAC 230 VAC DIN terminal (With surge voltage suppressor) 48 VAC 2G 2H 2V 2J 220 VAC 240 VAC 24 VAC 12 VDC 24 VDC 2K 2L 100 VAC 110 VAC 200 VAC 230 VAC 2M 2N 2P 2Q 2R 2S Conduit terminal (With surge voltage suppressor) 48 VAC 220 VAC 240 VAC 2W 24 VAC 12 VDC 24 VDC 2T 3A 3B 3C 3D
;git) (3d;git) (3dlgit) (3digit) Fluid Air,noncorrosive gas +3% F.
line Dryer The malfunction of air bearings of 3D measurement device, etc. 3 IDFB Series Model Selection Air dryers should be selected based on the corrected air flow capacity while taking operating environment and facility into account.
Exploded view (1) (4) (7) (5) (6) (3d)(3b) (3c) (3) (9) (3a) (3e) i Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (9) (3e) Magnifying figure (2a) Self-up screw 2 1 3 (2b) Comparison between the Product Model No. and the Coil Part No. Product model no.
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: N (NPT), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: Rc, Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: N (NPT), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: F (G), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: T (NPTF), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: F (G), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: N (NPT), Passage: A (Normally Closed)