line Dryer The malfunction of air bearings of 3D measurement device, etc. 3 IDFB Series Model Selection Air dryers should be selected based on the corrected air flow capacity while taking operating environment and facility into account.
In that case, loosen the screw with washer (3e) and place a lead wire (3d) into the bracket, and then tighten it once again. b Maximum size of crimped terminal (9) is up to 1.25 mm2 3.5 when O terminal.
Exploded view (1) (4) (7) (5) (6) (3d)(3b) (3c) (3) (9) (3a) (3e) i Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (9) (3e) Magnifying figure (2a) Self-up screw 2 1 3 (2b) Comparison between the Product Model No. and the Coil Part No. Product model no.
10.8 0B 204 2B 41 4B 10.4 0C 187 2C 40 4C 10 0D 173 2D 38 4D 9.7 0E 160 2E 37 4E 9.4 0F 150 2F 36 4F 9.1 10 140 30 35.2 50 8.8 11 132 31 33.1 51 8.3 12 125 32 31.3 52 7.8 13 118 33 29.6 53 7.4 14 112 34 28.1 54 7.0 15 107 35 26.8 55 6.7 16 102 36 25.6 56 6.4 17 97 37 24.5 57 6.1 18 93 38 23.4 58 5.9 19 90 39 22.5 59 5.6 1A 86 3A 21.6 5A 5.4 1B 83 3B 20.8 5B 5.2 1C 80 3C 20.1 5C 5.0 1D 77 3D
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: Rc, Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: N (NPT), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: F (G), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: T (NPTF), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: F (G), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: N (NPT), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 06 (3/4), Thread: N (NPT), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 04 (1/2), Thread: Rc, Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: T (NPTF), Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: Rc, Passage: A (Normally Closed)
Pilot: Internal Pilot, Voltage: 3 (110VAC 50/60HZ), Lead Wire: D (DIN Connector), Surge Suppressor: None, Port Size: 10 (1), Thread: F (G), Passage: B (Normally Open)
Pilot: Internal Pilot, Voltage: 110VAC 50/60HZ, Lead Wire: DIN Connector, Surge Suppressor: None, Port Size: 3/4, Thread: NPTF, Passage: Normally Closed, Option: -, CE Compliant: -