When the ambient Continuous monitoring temperature is out of the range between the temperatures set for AS.04 and AS.06, AL.03 or AL.04 may be generated at the same time when the product is turned ON.
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
Status (2): The circulating fluid temperature becomes within the set range of "AS.04". "AS.04" alarm monitoring starts. Status (3): The circulating fluid temperature exceeds the threshold of "AS.06", but the alarm will not be generated as it has returned within the 600 sec range of the "AS.23: Range over detecting timer".
VY1 How to Order G PPA Internal pilot operated relieving type regulator AR 25 4 BG R 02 Option Nil Flow direction: Right Left AL None Regulator R Body size Accessory 4 6 8 9 1 2 1 Symbol Description Applicable model Port size 1 Nil 1 4 02 03 04 06 10 12 14 20 2 1 With bracket AR45 to 65 AR25 AR35 B 8 3 2 G46-10-02 G46-2-02 Gauge 1 2 3 4 G Regulating pressure range Pressure gauges are shipped
When a pressure gauge is included, the display will show a range from 0 to 1.0 MPa. w 449 Regulator AR10-A to AR40-A Symbol Regulator 2 1 How to order AR10-A AR30-A AR20-A AR 30 A q 03 e BG Option/Semi-standard: Select one each for a to g. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
Load proportion is ((load weight x 9.8)/theoretical force) x 100% Conditions of Speed Chart System A B C D E F G Solenoid valve Speed controller AS420-04 AS500-06 AS600-10 AS600-10 AS800-12 AS900-14 AS900-20 Tubing diameter x Length SGP15A x 1 m SGP20A x 1 m SGP25A x 1 m SGP25A x 1 m SGP32A x 1 m SGP40A x 1 m SGP50A x 1 m Silencer AN40-04 AN500-06 AN600-10 AN600-10 AN700-12 AN800-14 AN900
Regulator Series AR-B 1021Series ARK-B 1021Regulator with Backflow Function How to Order Clean series K F 10 AR B 30 03 BG 1N K F 21 AR B 30 03 BG 1N Copper, fluorine and silicone-free + Low particle generation q r t y w e Regulator Option/Semi-standard: Select one each for a to g.
K F 10 AW B 30 03 BG JN K F 21 AW B 30 03 BG JN Copper, fluorine and silicone-free + Low particle generation q r t y w e Filter regulator Option/Semi-standard: Select one each for a to g.
Bore Order No. 32 CK95-32 40 CK95-40 50 CK95-50 63 CK95-63 80 CK95-80 100 CK95-100 1.8-14 ISO/VDMA Air Cylinders Series CP95K Dimensions non-rotating rod specification [mm] CP95KB-Stroke Stroke end cushioning STROKE STROKE CP95KB-Stroke W STROKE STROKE STROKE Bore AM B D EE PL RT I12 KK SW SW1 G BG I8 VD VA WA WB WH ZZ ZY E R I2 Ig 32 22 30 12 G1/8 13 M6 6 M10x1.25 10 12.2 27 16 94 40
Flow Rate Characteristics Relief Characteristics IR3020-04-A Supply pressure: 0.7 MPa IR3020-04-A Back pressure: 0.7 MPa 0.7 0.7 0.6 0.6 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 5000 6000 0 0 1000 2000 3000 4000 5000 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics Supply pressure: 0.3 to 1.0 MPa Set pressure
Size: 3 (Body Ported), Operation: 0 (Air Operated Style), Sealant: Nitrile Rubber, Port Size: 04 (1/2), Thread: Rc(PT), Option: GN (Pressure Gauge+Silencer for Bleed Port)
Size: Body Ported, Operation: Air Operated Style, Sealant: Nitrile Rubber, Port Size: 1/2, Thread: Rc(PT), Option: Pressure Gauge+Silencer for Bleed Port
Body Size: 40, Backflow: K (w/Backflow Function), Thread: Rc, Port Size: 04 (1/2), Options: BG (B+G), Set Pressure: 0.05 to 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Flow Direction: R (Right to Left), Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa
Body Size: 3, Set Pressure: 2 (0.02 to 0.8 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: BG (B + G), Semi-standard: None
Body Size: 3, Set Pressure: 0 (0.02 to 0.2 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: N (NPT), Port Size: 04 (1/2), Option: BG (B + G), Semi-standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi)
Body Size: 3, Set Pressure: 0 (0.02 to 0.2 MPa), Exhaust Direction: 0 (Bottom Exhaust), Thread: Rc, Port Size: 04 (1/2), Option: BG (B + G), Semi-standard: None
Size: 4 (Size 425 Port Size 1/4,3/8,1/2 Flow 8000Nl/min), Pressure Setting: 2 (0.85MPa), Thread: N (NPT), Port Size: 04 (1/2), Accessory: BG (Bracket + Gauge)