Without lead wire: (with connector and 2 of sockets only) SY100-30-A Rated voltage Lead wire length 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] Nil 6 10 15 20 25 30 50 300 mm 600 mm 1000 mm 1500 mm 2000 mm 2500 mm 3000 mm 5000 mm Electrical entry G H L LN LO M MN MO W0 Grommet, 300 mm lead wire Grommet, 600 mm lead wire
/location) Pilot port blocking disk: SZ3000-114-2A Supply/exhaust block assembly (8): SZ3000-50-2A-C8 Supply/exhaust block assembly (6): SZ3000-50-2A-C6 External pilot block assembly (6): SZ3000-54-2A-C6 External pilot block assembly (4): SZ3000-54-2A-C4 For SMC use only Enter the ordered part numbers. Part No. Quantity Part No. Quantity Order No. Clerk (code No.)
Coil voltage Configuration Note 2) VQ1000 VQ2000 1 2 3 4 5 6 VQ0 100V AC (50/60Hz) 2 position single 1 2 3 4 5 200V AC (50/60Hz) 2 position double (latching) 110V AC (50/60Hz) Electrical entry (2) (1) 3 position closed center 220V AC (50/60Hz) 24V DC 12V DC Grommet (Except for double (latching) and AC.)
, 400, 415 VAC (50 Hz) 380 to 420 VAC (60 Hz) 420, 440, 480 VAC (50 Hz) 420 to 520 VAC (60 Hz) 220 VAC (50 Hz) 220 to 240 VAC (60 Hz) 380, 400, 415 VAC (50 Hz) 380 to 400, 400 to 415, 415 to 440 VAC (60 Hz) 440, 460 VAC (50 Hz) 440 to 460, 460 to 500 VAC (60 Hz) Outlet voltage Symbol 500 1 500 VA 100 VAC (50 Hz) 100, 110 VAC (60 Hz) 1000 2 1 kVA Singlephase 2000 2 kVA 3 4 9 200 VAC (50 Hz
SV3000 In case of mixed specification (M), indicate separately on a manifold specification sheet.
GA pin CG1 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com KK UNF 2A KK UNF 2A FF UNF 2A D across flats NN mounting nut (included) D across flats LB + ZC per 1" of stroke MB LB + ZC per 1" of stroke NN mounting nut (included) NN UNF 2A (in) MB1 Bore size (in) MM KK
/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] With surge voltage suppressor (Non-polar type) T With light/surge voltage suppressor (Non-polar type) With surge voltage suppressor (Non-polar type) Power saving circuit is not available for W type.
220 VAC 50/60 Hz [230 VAC 50/60 Hz] 4 For type W, only DC voltage is available.
Rated voltage 5 6 V S R 1 2 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz [115 VAC 50/60 Hz] 220 VAC 50/60 Hz [230 VAC 50/60 Hz] Electrical entry G H L LN LO M MN MO W0 Grommet (300 mm lead wire) Grommet (600 mm lead wire) With lead wire Without lead wire Without connector With lead wire Without lead wire Without connector Without connector cable Electrical
SZ3000-73-2A-L6 SZ3000-56-1A VVQ1000-51A-C6 VVQ1000-51A-C8 SZ3000-74-1A-L6 SZ3000-74-1A-L8 SZ3000-74-2A-L6 SZ3000-74-2A-L8 4(A), 2(B) port 1(P), 3(R) port Other Tube Brands Caution 1.
Therefore, also check the allowable load for the selected conditions. 6.1 10 16 20 25 32 40 MX 0.8 6.1 1.1 0.8 6.1 10.8 3.7 10.8 4.9 3.7 10.8 40 50 40 50 40 50 17.6 MTS 11 17.6 16 11 17.6 MY1H 27.5 23 27.5 26 23 27.5 30 30 30 39.2 MY 39 39.2 50 39 39.2 20 50 39 50 50 50 50 20 20 CY The above values are the maximum allowable values for moment and load.
wire Without connector 50 60 2 200 VAC Hz M M plug connector 50 60 110 VAC Hz [115 VAC Hz] MN MO M8 connector Without connector cable W0 3 50 60 50 60 50 60 4 220 VAC Hz [230 VAC Hz] Note) For connector cable of M8 connector, refer to page 225.
Coil rated voltage VP7 1 2 3 4 5 6 100V AC (50/60Hz) 200V AC (50/60Hz) 110V AC (50/60Hz) 220V AC (50/60Hz) 24V DC 12V DC VP4 VQ VQ4 Wiring Specifications VQZ The lead wires are connected to the valve as shown below. Connect each to the power supply side.
Minimum Strokes for Auto Switches Mounting (mm) Number of switches 2 n Auto switch model On the same surface On different surfaces On the same surface 1 On different surfaces D-C7 D-C8 D-H7l D-H7lW D-H7BAL D-H7NF D-C73C D-C80C D-H7C 10 50+45(n2) 50 15 n2 2 15+45 ( ) (n=2, 4, 6) 10 60+45(n2) 60 15 n2 2 15+50 ( ) 10 65 15 (n=2, 4, 6) 65+50(n2) n2 2 20+50 ( ) (n=2, 4, 6) D-H7LF 10 65 20 D-B5
VR VH Body ported single solenoid Foot bracket VFA3122 F 02 VHS Body ported For 30 type manifold VFA3 1 0 3 02 Base mounted For 40 type manifold VFA3 1 0 4 02 Port size For 50 type manifold VFA3 1 50 W/o sub-plate (Pilot port: Rc) Nil W/o sub-plate (Pilot port: Other than Rc) Thread type for pilot port 00 For 60, 61,70, 71 manifold VFA3 1 0 6 02 02 03 1 4 3 8 Nil 00F 00N 00T Rc G NPT NPTF
53.5 66 68 29 36 37 65.5 76.5 84 30 35 40 13.5 15 16.5 20 22 24.5 45 53 58 22.5 26.5 29 22 27 31 52 62 67 26 31 33.5 30 35 40 47.5 50 52.5 36.5 45 50.5 23 25.5 28 42.5 51 56.5 C8, C10 C10, C12 Replacement Parts DIN Connector Part No.
301 to 400 156 160 160 165 401 to 500 181 185 185 190 20 25 32 40 30 32 32 41 36 36 36 46 24 24 24 25 With Rod Boot l ZZ Symbol Z 1 to 50 143 147 149 181 Stroke Bore size (mm) 1 to 50 12.5 12.5 12.5 12.5 51 to 100 25 25 25 25 101 to 150 37.5 37.5 37.5 37.5 151 to 200 50 50 50 50 201 to 300 75 75 75 75 301 to 400 100 100 100 100 401 to 500 125 125 125 125 1 to 50 63 67 67 71.5 51 to 100 76
-30-2A-30 connector assy, SY3000 SOL/VALVE, RUBBER SEAL*** $5.26 Add to Quote Add To Cart Add to Cart SMC SY100-30-2A-50 connector ass'y, 3 PORT SOLENOID VALVE $5.25
Note Description C6 C8 SZ3000-50-1ASZ3000-53-1A SX3000-113-1 SZ3000-114-3A SZ3000-114-1A VZ1000-11-1SZ3000-40Supply/Exhaust block assembly C6: with 6 One-touch fitting, C8: with 8 One-touch fitting 1 End block assembly 2 Housing holder 3 Bushing assembly 4 Bushing assembly 5 Refer to page 7 DIN rail 6 Refer to the connector block assembly part no. table below.
8 10 46.5 7 12 M14 x 1.5 42.5 M32 x 2 1/4 88 188 With Rod Boot (mm) Bore size B3 e f h l ZZ (Both sides) 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 1 to 50 51 to 100 101 to 150 151 to 200 201 to 300 20 30 36 18 68 81 93 106 131 12.5 25 37.5 50 75 198 224 248 274 324 25 32 36 18 72 85 97 110 135 12.5 25 37.5 50 75 206 232 256 282