SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ7-20-03-00N"

Nijverheidsstraat 20 B-2160 Wommelgem Belguim TEL: 03-355-1464 FAX: 03-355-1466 TAIWAN SMC Pneumatics (Taiwan) Co.,Ltd. 17, Lane 205, Nansan Rd., Sec.2, Luzhu-Hsiang, Taoyuan-Hsien, TAIWAN TEL: 03-322-3443 FAX: 03-322-3387 POLAND SMC Industrial Automation Polska Sp.z.o.o. ul.

Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted

Applicable solenoid valve Type 20 How to Order G L M D Option VV4Z1 05 20 1 4(A), 2(B) port VZ1120-M5 Applicable blanking plate assembly DXT170-25-1A Individual EXH spacer assembly DXT170-48-1A Individual SUP spacer assembly DXT170-44-1A Stations P, R port thread type 02 2 stations F: With foot bracket 20 20 stations Nil Rc G NPT 1(P) port 00F 00N 3(R) port NPTF 00T Bracket is not mounted

bracket (Not mounted) 20 Rc G NPT NPTF 20 stations 00F 00N 00T CE-compliant P port: Rc 1/8 R port: Rc 1/8 Q CE-compliant Nil Note) Applicable only for DIN terminal type Type 40: Base mounted (A port bottom ported) How to Order Applicable solenoid valve VK334-(-Q) Applicable blanking plate assembly VK300-42-1A Bracket VK300-43-1A VV3K3 05 40 01 Thread type Option Valve stations P port: Rc

VK332--M5 VK332--01 Applicable blanking plate assembly VK300-42-1A VV3K3 05 21 A port: Rc 1/8, M5 x 0.8 Thread type Valve stations 01 1 station Nil Rc G NPT NPTF 00F 00N 00T 20 20 stations P port: Rc 1/8 R port: Rc 1/8 4-5-3 4 Series VK300 Combinations of Solenoid Valve, Manifold Gasket and Manifold Base 3 port body ported: VK332 3 port base mounted: VK334 M3 x 26 Round head combination

VV5FA5-20-051 1 pc. VFA5120-03 2 pcs. VFA5220-03 2 pcs. DXT156-19-1A 1 pc.

Refer to p.0-33 to 0-36 for Safety Instructions and common precautions. 0.2 SS5YJA3-41-03-M51 pc. SYJA3140 1 pc. SYJA3240 1 pc.

Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

Example: SS5YJ3-20-03 1 set (Manifold base) SYJ3120-5G-M3 2 sets (Valve) SYJ3000-21-1A 1 set (Blanking plate assembly) SS5YJ3-S41-03-C4 1 set (Manifold base) SYJ3140-5LZ 2 sets (Valve) SYJ3000-21-2A 1 set (Balnking plate assembly) The asterisk denotes the symbol for assembly. Prefix it to the part nos. of the solenoid valve, etc.

(Example) SS3YJ3-20-03 . 1 set (manifold base) SYJ312-5LZ-M3 . 2 sets (valve) SYJ300-10-1A . 1 set (blanking plate assembly) SS3YJ3-42R-03-C4 . 1 set (manifold base) SYJ314R-5G . 2 sets (valve) SYJ300-10-2A . 1 set (blanking plate assembly) The asterisk denotes the symbol for assembly.

VQD 24V 12V 100V 200V 110V 220V 24V DC 12V DC 100V AC 200V AC 110V AC 220V AC AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 To remove manifold from DIN rail: 1) Loosen the clamp screw on the A side of both ends of the manifold. 2) Lift the A side of the manifold off the DIN rail and slide it in the direction of the B side.

The proper tightening torque for screws 0.3 to 0.4 Nm Rated voltage With indicator light VZ Voltage symbol Part no. 24 VDC 12 VDC 100 VAC 200 VAC 110 VAC 220 VAC 24V 12V 100V 200V 110V 220V AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 VS (b) VFN Valve Mounting Circuit with Indicator Light After confirming the gasket is correctly placed under the

AXT100-20-2-05 AXT100-20-2-06 AXT100-20-2-01 AXT100-20-2-02 AXT100-20-2-03 AXT100-20-2-04 Valve Mounting VS After confirming the gasket is correctly placed under the valve, tighten the mounting screws with the appropriate torque listed below.

NPT 00T NPTF 00F G Stations Body Ported Symbol Stations 02 2 stations 03 3 stations Option Symbol Type Nil None R External pilot 20 20 stations Note) Max. 20 stations Individual wiring How to Order Valves How to Order Manifold Assembly Specify the part numbers for valves and options together beneath the manifold base part number.

VV5K3-20-06 VV5K3-40-06-M5 Common SUP/Common EXH VK Type 20: Body ported (A, B port top ported) Applicable solenoid valve VK3120M5 VK312001 VK332M5 VK33201 How to Order A port: Rc 1/8, M5 x 0.8 VZ VV5K3 20 05 A, B port Rc 1/8, M5 x 0.8 VK3120 Thread type VF VK332 Valve stations Nil 00F 00N 00T Rc 01 1 station Applicable blanking plate assembly VK3000-7-1A VFR G NPT 20 20 stations R port:

Nil Rc Applicable blanking plate assembly VK3000-7-1A 00F 00N 00T G 20 20 stations R port: Rc 1/8 P port: Rc 1/8 R port: Rc 1/8 NPT Note) Applicable only for DIN terminal type NPTF Type 40: Base mounted (A, B port bottom ported) How to Order Applicable solenoid valve VK3140-(-Q) VK334-(-Q) Type VK334 Type VK3140 VV5K3 40 05 M5 R port: Rc 1/8 P port: Rc 1/8 R port: Rc 1/8 Thread type Nil Valve

Series: 5 (VFA5000), Manifold: 20 (P.R Port Size 3/8), Stations: 03, Type: 1 (Common Exhaust), Thread: 00N (NPT)