SMC Corporation of America
Elite Part Number Search
Search Results "SS5YJ3-S32-05-C4"

C4 Type SS3YJ3-S42-M5 Type SS3YJ3-S42-C4 M5 x 0.8 C4 SYJ34 1/8 Body ported for external pilot Type SS3YJ3-20R 0.9 SYJ32R 1/8 M3 x 0.5 Type SS3YJ3-42R-M5 Type SS3YJ3-42R-C4 Type SS3YJ3-S42R-M5 Type SS3YJ3-S42R-C4 0.17 0.36 0.30 0.17 0.31 0.33 0.32 0.35 0.075 0.086 0.079 0.082 0.32 0.33 0.33 0.35 0.11 0.20 0.35 0.26 0.072 0.082 0.086 0.086 M5 x 0.8 C4 SYJ34R 1/8 Base mounted for external

C4: 4 (SMC) N3: 5/32" (SMC) One-touch fitting [X: External pilot port] Applicable tubing O.D. C4: 4 (SMC) N3: 5/32" (SMC) (9.5) (43.9) One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.

Tie-rod base SS5V 1 A D 05 U 10S3 Cassette base U SS5V D 05 16S3 1 A Series DIN rail length 1 2 SV1000 SV2000 Standard length Nil 3 Specify a rail longer than the standard length.

Passage Porting specifications Symbol 4(A), 2(B) Side 5(R1), 3(R2) 1(P) Common Common 1 Non Plug-in Type: Stacking Type Manifold Base Wiring for every valve VV5ZS2 C4 06 51 1 Thread type Series VZS2000 Manifold Standard Nil NPT Rc N T F Non plug-in type Stacking type manifold base NPTF G Option Port size Rc 1 8 01 Embedded type One-touch fitting Applicable tubing O.D.: 4 Stations C4 02 2

2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations Rc 1/4 1 8 Rc Nil F N Z NPTE 01 Rc C6 One-touch fitting for 6 4(A), 2(B) port G 20 20 stations 1(P) port Rc 1/8, C6 NPT B7 One-touch fitting for 1/4" Rc 1/4 How to Order Type 43 VV5Z3 05 43 1 C4 1(P), 3/5(R) port thread type 4(A), 2(B) port size Stations 02 2 stations 3/5(R) port Nil F N Z NPTE Rc C4 One-touch fitting

Applicable up to 16 solenoids. 20 16 08 20 stations 16 stations 8 stations Type 45T (9 pins terminal block type) Type 45T1 (18 pins terminal block type) 45T1 SS5X 3 05 U C4 D 45T SS5X 3 05 U C4 D Series Series 3 SX3000 5 SX5000 3 SX3000 5 SX5000 Option Option Terminal block mounting position When a longer DIN rail is desired than the specified stations, specify the station number to be required

JSY1000 manifold pitch for C2 and C4 is 6.5 mm, and 9 mm for C6.

2(B) port size 1(P), 3/5(R) port thread type 3/5(R) port 02 2 stations Rc 1/4 1 8 Rc Nil F N Z NPTE 01 Rc C6 One-touch fitting for 6 4(A), 2(B) port G 20 20 stations 1(P) port Rc 1/8, C6 NPT B7 One-touch fitting for 1/4" Rc 1/4 How to Order Type 43 VV5Z3 05 43 1 C4 1(P), 3/5(R) port thread type 4(A), 2(B) port size Stations 02 2 stations 3/5(R) port Nil F N Z NPTE Rc C4 One-touch fitting

Manifold Specifications SV1000 SV2000 SV3000 SV4000 Applicable series Manifold type 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) Max. number of solenoids Tie-rod base manifold Common SUP, EXH 20 stations 32 points 1(P), 3/5(E) port C8, N9 C3, C4, C6 N1, N3, N7 C10, N11 C4, C6, C8 N3, N7, N9 C12, N11 C6, C8, C10 N7, N9, N11 C12, N11, 03 C8, C10, C12 N9, N11, 02, 03 Port size 4(A)

Dimensions VQZ Single unit Manifold VQD 2n-C4, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 2-C4, C6 C4: One-touch fitting for 4 C6: One-touch fitting for 6 ~ = 4.5 Mounting hole for M3 Mounting hole for M2.5 ~ = 4.5 Residual pressure release manual override Residual pressure release manual override DIN rail clamp screw 2-C3, C4, C6, M5 C3: One-touch fitting for 3.2 C4: One-touch

Type 10-SS3YJ3-S42-M5 Type 10-SS3YJ3-S42-C4 Base mounted for internal pilot 0.17 0.36 0.3 0.17 0.31 0.33 0.32 0.35 0.075 0.086 0.079 0.082 0.32 0.33 0.33 0.35 0.11 0.2 0.35 0.26 0.072 0.082 0.086 0.086 M5 x 0.8 10-SYJ34M 1/8 C4 M5 x 0.8 C4 10-SYJ34M 1/8 Note) The values are for individually operated 2 position type manifold bases.

Applicable up to 16 solenoids. 20 16 08 20 stations 16 stations 8 stations Type 45T (9 pins terminal block type) Type 45T1 (18 pins terminal block type) 45T1 SS5X 3 05 U C4 D 45T SS5X 3 05 U C4 D Series Series 3 SX3000 5 SX5000 3 SX3000 5 SX5000 Option Option Terminal block mounting position When a longer DIN rail is desired than the specified stations, specify the station number to be required

C6 C6 Cylinder port size SX3000 C6: With One-touch fittings for 6 Manifold base (5 stations) SX5000 SS5X3-41-05-C6 One-touch fitting (Inch size) Symbol Port size Applicable series One-touch fitting for 5/32" N3 SX3000 One-touch fitting for 1/4" N7 SS5X3-41-05-C6 1 set (Type 41, 5-station manifold base part no.)

(ZX1A) ZX1AK6 r 05 ZX1 1 D W Table (2) How to Order Solenoid Valves Assembly no. Z L 5 ZX1 VJ114 Ejector unit nozzle dia. 05 07 0.5 mm 0.7 mm 10 1.0 mm 1 2 With silencer Port exhaust 3 Common exhaust Z L 4 2 5 ZX1 VJ3 Ejector type (Exhaust type) Manual override Type of actuation Nil B Non-locking push type Locking slotted type 1 2 N.C. (Normally closed) N.O.

C4 SJ3l60-C4 SJ2l60-C4 4 onetouch fitting 4 onetouch fitting 3 position 4 position 3 position 4 position 77 48 73 61 69 44 39 42 2 position 2 position C6 SJ3l60-C6 SJ2l60-M3 6 onetouch fitting M3 x 0.5 3 position 4 position 3 position 4 position 73 69 57 65 69 46 42 Note) Please contact SMC for the weight of elbow fittings. 2 position SJ3l60-M5 M5 x 0.8 3 position 4 position 65 Note) Please

of P port and exhaust air from both sides of R port. 40R-1 Applicable solenoid valve VZ314RVZ324RApplicable blanking plate assembly DXT200-8-3A How to Order VV3Z3 40R 05 1 M5 Stations A port side 2 stations 02 X port P/R port Thread type M5 x 0.8 1/8 M5 01 C4 C6 B3 B7 P port 20 stations 20 Nil Rc G NPT NPTF One-touch fitting for 4 A port F N T One-touch fitting for 6 R port M5 x 0.8, 1/8

Dimensions Single unit Manifold 2 x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting 2 x C4, C6 C4: 4 one-touch fitting C6: 6 one-touch fitting Mounting hole for M3 Mounting hole for M2.5 Manual override for residual pressure exhaust Manual override for residual pressure exhaust DIN rail clamping screw Stations12 3 D side U side 2 x C3, C4, C6, M5 C3: 3.2 one-touch fitting C4: 4 one-touch

When the port size of the external pilot block assembly is 4, indicate with C4 in section (c).

(When port sizes for A, B ports are mixed, indicate C4 or C6 in cell .)