SX5000-38-16 A SX7000-39-16 A SX7000-38-16 A Dimensions Applicable fittings size d 4 Model A L D KQ2P-04 16 32 6 6 KQ2P-06 18 35 8 8 KQ2P-08 20.5 39 10 10 5/32" 1/4" 5/16" 3/8" Thread type Nil Rc G F KQ2P-10 KQ2P-03 KQ2P-07 KQ2P-09 KQ2P-11 12 6 8.5 10 11.5 43 32 35 39 43 22 16 18 20.5 22 N NPT NPTF T Bolt and gasket part no.
Manifold Specifications SV1000 SV2000 SV3000 SV4000 Applicable series Manifold type 1 (P: SUP)/3, 5 (E: EXH) type Valve stations (maximum) Max. number of solenoids Tie-rod base manifold Common SUP, EXH 20 stations 32 points 1(P), 3/5(E) port C8, N9 C3, C4, C6 N1, N3, N7 C10, N11 C4, C6, C8 N3, N7, N9 C12, N11 C6, C8, C10 N7, N9, N11 C12, N11, 03 C8, C10, C12 N9, N11, 02, 03 Port size 4(A)
Entry is the same as standard products. 933 Series VQZ Replacement Parts Body Ported One-touch Fitting Assembly (for Cylinder port) Fitting size C3 C4 C6 C8 C10 Model VQZ1000/2000 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VQZ3000 VVQ1000-51A-C6 VVQ1000-51A-C8 VVQ1000-51A-C10 Note) Purchasing order is available in units of 10 pieces.
External pilot specification Dual flow fitting SSQ2000-52AC10 C10: 10 One-touch fitting N11: 3/8" One-touch fitting Bore size C10 N11 10 3/8" To drive a large bore cylinder, two valve stations are operated simultaneously to double the air flow. This fitting is used on the cylinder ports in this situation. Available sizes are 10 and 3/8" One-touch fittings.
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 one-touch fitting C10 [1(P) SUP port] C10: 10 one-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
14 145 43 14 220 220 220 220 220 220 340 340 340 340 460 460 460 460 460 460 1/8 C6 13/64 VX210 1 5/64 1/8 C8 13/64 5/32 9/32 5/32 9/32 C8 VX220 2 C10 13/64 5/16 C10 25/64 13/64 VX230 3 5/16 C12 25/64 Note) Weight of grommet type.
Bore size (mm) Z Z B DA DB DL DU DC DX DE DR DO DT DS DH DD H10 +0.058 0 +0.058 0 +0.070 0 +0.070 0 +0.084 0 +0.084 0 +0.084 0 32 40 50 63 80 100 125 32 40 50 63 80 100 125 33 33 45 45 65 65 75 46 52 65 75 95 114 136 32 32 43 43 64 64 78 22 22 30 30 45 45 60 10 10 11.5 11.5 14 14 15 44 44 60 60 86 86 110 14 14 20 20 30 30 32 62 62 81 81 111 111 136 6.6 6.6 9 9 11 11 13.5 15 15 18 18 22 22
External pilot specifications Dual flow fitting SSQ2000-52AC10 C10: One-touch fitting for 10 N11: One-touch fitting for 3/8" Port size C10 N11 10 3/8" To drive a large bore cylinder, two valve stations are operated simultaneously to double the air flow. This fitting is used on the cylinder ports in this situation. Available sizes are 10 and 3/8" One-touch fittings.
[3(R) EXH port] (C12 in case of branch type) C10 [3(R) EXH port] C10: 10 One-touch fitting C10: 10 One-touch fitting (C12: 12 One-touch fitting) DIN rail clamp screw R R 76.5 3 3 X X 49.5 B B B B B B B B 12 P12 P 30 25 18 1 1 A A A A A A A A 10 13.5 C10 [1(P) SUP port] C10: 10 One-touch fitting C10 [1(P) SUP port] (C12 in case of branch type) C4, C6, C8, [4(A), 2(B) port] P = 16 45 25 C10
(L4) (L3) (5.25) L2 L1 Made by CONINVERS GmbH HC-26P1NRAWF00 34.5 6.5 59 Indicator light Manual override 4 x M5 mounting hole 73.5 <77.5> 1 0.9 29.5 (35) (5.5) 120 <126.9> 22 10.6 80 4 46.2 (12) 13 73.7 U side D side n 8 7 Stations 6 5 4 3 2 1 C10 [3(R) EXH port] C10: 10 One-touch fitting C10 [1(P) SUP port] C10: 10 One-touch fitting R EXH R EXH DIN rail clamp screw B B B B B B B B P X P
17 6 16 12 MAX. 20 ML2B40 4.5 15 31 9.5 94 81.5 67.3 43 17 6 16 12 MAX. 25 Part No.
Applicable bore size (mm) Dd9 L d L2 m t Included retaining ring IY-G02 20 8 0.040 0.076 21 7.6 16.2 1.5 0.9 Type C8 for axis IY-G03 25, 32 10 0.040 0.076 25.6 9.6 20.2 1.55 1.15 Type C10 for axis IY-G04 40 10 0.040 0.076 41.6 9.6 36.2 1.55 1.15 Type C10 for axis IY-G05 50, 63 14 0.050 0.093 50.6 13.4 44.2 2.05 1.15 Type C14 for axis IY-G08 80 18 0.050 0.093 64 17 56.2 2.55 1.35 Type C18
EtherCAT is registered trademark and patented technology, licensed by Beckhoff Automation GmbH, Germany. 43 These safety instructions are intended to prevent hazardous situations and/or equipment damage. These instructions indicate the level of potential hazard with the labels of Caution, Warning or Danger.
SET side tubing O.D. 6, 8, 10 1/4" , 5/16" , 3/8" 6, 8 1/4" , 5/16" 135 g (IRV10-C08) 125 g (IRV10A-C08) 250 g (IRV20-C10) 250 g (IRV20A-C10) Weight (Without accessories) Standard connections Single sided connections Note 1) Use caution it varies depending on the pressure in vacuum pump side.
(The standard valve has an individual exhaust for the pilot valve.) 1.12-58 Series VQZ Base Mounted Replacement Parts One-touch Fitting Assembly (For cylinder port) C3 C4 C6 C8 C10 Fitting Size Series VQZ1000 VVQ1000-50A-C3 VVQ1000-50A-C4 VVQ1000-50A-C6 VVQ1000-51A-C8 VQZ2000 VVQ1000-51A-C4 VVQ1000-51A-C6 VVQ2000-51A-C8 VVQ2000-51A-C10 VQZ3000 SY VVQ2000-51A-C6 Note) Order is accepted in
Hold down again for 1sec. or longer after interval No.IP8S-OM09 61 Mode button 1s Set button 1s or Mode button 1s Set button 1s or Mode button 1s Mode button 1s Set button Set button 1s 1s Fig. 43-1 Mode button 1s Set button 1s or Lower limiter Upper limiter Fig. 43-2 Mode button 1s Set button 1s Alarm setting Fig. 43-3 No.IP8S-OM09 62 Possible to select analog output proportional
L-type plug connector (L): VQZ3l2l-lLl1-C6, C8, C10 85.8 [88] Approx. 300 (Lead wire length) 32 [39] 93.7 Max. 10 53.8 Applicable cable O.D. 3.5 to 7 Pg7 Unless otherwise indicated, dimensions are the same as Grommet (G). [ ]: AC M-type plug connector (M): VQZ3l2l-lMl1-C6, C8, C10 61.3 53.8 (Lead wire length) 42.5 33.4 Approx. 300 43.3 [50.3] 76 [78.2] 71 94.6 Unless otherwise indicated,
-43 (5(R1), 3(R2) port) Before using, refer to page 3-3-8.