Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100.kPa)], Port Size: 01 [R 1/8 (w/M5 Female Thread)], Output Specification: 28 [Current Output (4~20mA) Type], Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
SI Unit for VQC/S0700 Series Valves ( EX500-Q 01 ) SI Unit for SV Series Valves ( EX500-S 01 ) M3 28: 4 pcs. ( Plus-minus slot round head screw ) Supply/exhaust block assembly Supply/exhaust block assembly 1.
Stations Port location R16 Arrangement (Right valve station which is looked from valve side is first station.) 01 1 Left side Right side R L B 06 6 Refer to (About individual spacer.)
G33-4-01 G33-10-01 G43-2-01 G43-4-01 G43-10-01 G43-10-01 G43-4-01 G43-10-01 Accuracy + 3% (full span) Courtesy of Steven Engineering, Inc. !
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 1 8 1 4 1 8 1 4 3 8 1 8 1 4 3 8 1 8 1 4 3 8 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 1 4 3 8 1 2 KFT04-01 KFT04-02 KFT06-01 KFT06-02 KFT06-03 KFT08U-01 KFT08U-02 KFT08U-03 KFT08N-01 KFT08N-02 KFT08N-03 KFT10U-02 KFT10U-03
-06-X214 AS2301F-01-06-X214 2.
C2: 2 (SMC) C4: 4 (SMC) 9.1 (C6) 10.3 (C2, C4) D D 3/5 B 2 E 3/5 B 2 B 2 B 2 E B 2 27 (C2, C4) 25.8 (C6) A 4 A 4 A 4 1 P P 1 4 A 4 A S (Pitch of C2, C4) P = 6.5 One-touch fitting [1(P), 3/5(E) port] Applicable tubing: 8 (SMC) (Pitch of C6) P = 9 * Refer to page 97 for dimensions of external pilot and built-in silencer. * Refer to pages 65 to 68, 79, and 80 for dimensions when L6, b, and
8 Manifold Block Assembly Standard 18 mm and 26 mm sizes mixed MBS8020 01 D M MBS80 0 01 D 2 With/Without tie-rod Size 2 4 Size 18 mm Size 26 mm With/Without tie-rod Cylinder port size 01 01B Side ported 1/8 Bottom ported 1/8 Nil Nil -1 Included None 1 Included None Thread type Wiring specifications D S Double wiring Single wiring Rc NPTF G Note) Nil T F Note) Conforms to ISO1179-1 Thread
Signal 1 DC output 2 DC output 3 FG DC connector HED007-C2* (HED003-C2*, HED005-C2*) DDK D/MS3102A20-15S Connect the DC cable connector of Heat Exchanger. Pin No.
+.002 1.88 2.56 3.50 .75 NCA1-P325 1.25 0 0.75 +.004 .53 .78 .62 -.01 +.002 Courtesy of Steven Engineering, Inc. !
(If not specifying dimension C2, indicate instead.)
(If not specifying dimension C2, indicate instead.)
(If not specifying dimension C2, indicate instead.)
Budafoki ut 107-113 1117 Budapest TEL: 01-371-1343 FAX: 01-371-1344 SOUTH KOREA SMC Pneumatics Korea Co., Ltd. Woolim e-BIZ Center (Room 1008), 170-5, Guro-Dong, Guro-Gu, Seoul, 152-050, South Korea TEL: 02-3219-0700 FAX: 02-3219-0702 ROMANIA SMC Romania S.r.l. Str.
. (3) Common supply pressure (PV) connecting port size (4) Common vacuum burst pressure (PD) port Note 2) 01 Rc1/8 01N NPT1/8 01F G1/8 M5 M50.8 NIL Without PD port (PV = PD) M5 M50.8 PVPD Note 2)Refer to model indication for single unit (4) for the combinations of supply valve and release valve selectable. 14 - Doc. no.
LN1 1/8 LN3 5/32 10 ZFAZFBZFC 11 10 - No.ZB-OM00301 / 1 01 1 / 02 2 S / 1 S 12 12 PV PD 2 PD PVPD 01 Rc1/8 M5 M50.8PVPD 01N NPT1/8 2 01F G1/8 M5 M50.8 M50.8 M-5P ZB03 ZB04 ZB05 ZB06 PV N.C.