Sensor Range: 0 [Positive Pressure (0~1MPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer)
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: R04 (Ø4 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: ±2%F.S., Port Size: R04 (Ø4 Plug-In Reducer)
Sensor Range: 1 [For Vacuum (0~-101kPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer), Option: C2 [Connector for Pressure Sensor Controller (PSE300) 1 pc.]
Sensor Range: 3 [For Compound Pressure (-100~100kPa)], Accuracy: A (±1%F.S.), Port Size: R04 (Ø4 Plug-In Reducer)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 004 (0.4 MPa, −40 kPa, 40 kPa), OUT1 Hysteresis: 4 (0.04 MPa, 4 kPa, 4 kPa)
Sensor Range: 0 [Positive pressure (0 to 1 MPa)], Accuracy: ±2% F.S., Port Size: R04 (Ø4 Plug-In Reducer), Output Specification: N (NPN open collector 1 output), Lead Wire Termination: Basic, Set Value: P (Normal Output), OUT1 Set Value: 005 (0.5 MPa, −50 kPa, 50 kPa), OUT1 Hysteresis: 5 (0.05 MPa, 5 kPa, 5 kPa)
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, JD, PSE5*1 VAC SWITCH 1/8PORT NPT, .47300 lb
Pressure sensor for general purpose fluids, Fluid: fluid, including gas, that will not corrode SUS316L, Accuracy (ambient temp. of 25C): 1%F.S. or less, Repeatability: 0.2%F.S. or less, Enclosure: IP65, SENSOR, GENERAL FLUID, VACUUM, VACUUM SERIES, PSE531/PSE541/PSE561, KD, PSE5*1 VAC SWITCH 1/4PORT NPT, .66138 lb
. -109No.PS-OMW0012-C Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1
Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564, PSE574 0 to 500 kPa
. -67No.PS-OMU0012-C Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563, PSE573 -100 to 100 kPa -105 to 105 kPa 0.1 kPa PSE532 0 to 100 kPa -10 to 105 kPa 0.1 kPa PSE564
ZB-OM00201-B Suction Filter Specifications Filtration rating 30m Filtration area 130 2 Pressure sensor specifications/ ZB1-PS-A Model ZB1-PS1-A ZB1-PS3-A (Sensing part: Standard (PSE543) PSE541 model) Rated pressure range 0 to -101kPa -100 to 100kPa Proof pressure 500kPa Output voltage 1 to 5V DC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, ripple (P-P) 10% at max.
Cable specification Conductor area 0.15 mm2 (AWG26) Insulator Outside diameter 0.9 mm Sheath Finished outside diameter 4.8 Table for each pressure specification Applicable SMC pressure sensor Rated pressure range Display/set pressure range Display/min. setting unit PSE550 0 to 2 kPa -0.2 to to 2.1 kPa 0.001 kPa PSE531, PSE541, PSE561 0 to -101 kPa 10 to -105 kPa 0.1 kPa PSE533, PSE543, PSE563
ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (p-p) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.
ZK2-PS1-A ZK2-PS3-A Model (Sensing unit: Standard model (PSE541) (PSE543) number) Rated pressure range 0 to -101 kPa -100 to 100 kPa Proof pressure 500 kPa Output voltage 1 to 5 VDC Output impedance Approx. 1 k Power supply voltage 12 to 24 VDC 10%, Ripple (P-P) 10% or less Current consumption 15 mA or less Accuracy 2% F.S. (Ambient temperature at 25 oC) Linearity 0.4% F.S.
ZB1-PS1-A (PSE541) Rated pressure range Proof pressure Output voltage Output impedance Power supply voltage Current consumption Accuracy Linearity Repeat accuracy Effect of power supply voltage Temperature characteristics 72.5 psi (500 kPa) 1 to 5 VDC Approx. 1 k 10 to 24 VDC10%, Ripple (p-p) 10% or less 15 mA or less 2% F.S.
Body Size: 20 (ø20mm), Body Material: S (Stainless Steel), Mounting Plate: None, Attachment: w/o Vibration Suppression Cover, Pressure Sensor: S (with Pressure Sensor; Part Number PSE541-M5-X2)