Connections 1/4 NPT (S, C1, C2), converts also ND91_ connections to1/4 NPT. RC03 H127093 Cable assembly remote mount sensor cable 30 m, angle connector D3 D3B As D3 but two pressure gauges with connections 1/4 NPT (S, C2).
Note 1) Sampling air flow rate: Number of particles contained in 75l of air Note 2) Actuator: 1 million cycles Solenoid valve: 2 million cycles Particle generation characteristics of CM2 Particle generation characteristics of CXSL Particle generation characteristics of CY1B 106 106 106 Particle concentration (particles/m3) Particle concentration (particles/m3) Particle concentration (particles
CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M3 x 30L x 35L x 40L x 45L x 50L x 55L CQ-M5 x 30L x 35L x 40L x 45L Mounting bolt part no. CQ-M5 x 50L x 55L x 60L x 65L x 70L x 75L CQ-M5 x 35L x 40L x 45L x 50L x 55L x 60L x 65L x 70L x 75L x 80L Mounting method: Mounting bolt for through-hole mounting style of CQSYB is available as an option.
With External Pilot Specifications (Pitch) 24 P = 24 48.6 11 25 11.8 20 14.5 13.7 E 3/5 E 3/5 E 3 E 3 4 A A 4 A 4 A 4 A 4 A 4 A 4 A 4 4 A A 4 35.8 40.4 35 58.3 63.9 74.8 B 2 B 2 B 2 B 2 B 2 P 1 P 1 B 2 B 2 B 2 B 2 P 1 P 1 B 2 C2 C2 One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 12 3/8" One-touch fitting [4(A), 2(B) port] Applicable tubing O.D.: 8, 5/16" 10, 3/8" 12 X PE X PE
x 0.35 x 19 M3 x 0.35 x 23 M3 x 0.35 x 24 M3 x 0.35 x 28 M3 x 0.35 x 68 M3 x 0.35 x 72 M3 x 0.35 x 73 M3 x 0.35 x 77 y u Components Ejector unit + Vacuum switch/Filter unit i o For nozzle size 10, 13, 15 M3 x 0.35 x 84 4 [For ZSE4 spec.]
Bracket Mounting Procedure
x 0.35 x 19 M3 x 0.35 x 23 M3 x 0.35 x 24 M3 x 0.35 x 28 M3 x 0.35 x 68 M3 x 0.35 x 72 M3 x 0.35 x 73 M3 x 0.35 x 77 y u Components Ejector unit + Vacuum switch/Filter unit i o For nozzle size 10, 13, 15 M3 x 0.35 x 84 4 [For ZSE4 spec.]
M3 x 0.5 x 3L M8 x 1.25 x 8L (Bolt holder) (Hexagon socket head set screw) 31 0.5 45 45 3 3 5.3 5.3 250.2 250.2 16 32 2-M3 x 0.5 through 6.5 counter bore depth 5 (Same on the opposite side) 3.4 through 3 3 45 45 5.5 M2.5 x 0.45 x 6L (Cap screw) M3 x 0.5 x 12.5L (Hexagon bolt) and M3 x 0.5 (Hexagon nut) 2-M3 x 0.5 through Steel ball Plug 2-M3 x 0.5 through 2.75 (11) (10+ST) 250.2 4 Part no
EXH.1 (C1) 2 (C2) 4 93.7 23 19 VH 18.5 18.5 12 CYL.2 CYL.1 14 12 21 20 3 (E1) 1 (S) 5 (E2) VHS 0.5 MPa supply 30.5 26.4 3 x 1/4 VHS T.T.
(Example) For M3: L1 = 6 Applicable shaft types: S, Y L2 + (3 x P) L1 + ( 3 x P) Q1 = M Y axis S axis (mm) (mm) Q1 Q2 L1 = Shaft type Shaft type S Y S Y Size Size L2 + (3 x P) L2 = 50 50 M3, M4, M5, M6 M3, M4, M5 M3, M4, M5 L2= 63 63 M4, M5, M6 M4, M5, M6 M4, M5, M6 Q2 = M 80 80 M4, M5, M6, M8 M4, M5, M6 Q2 = M M4, M5, M6 100 100 M5, M6, M8, M10 M5, M6, M8 M5, M6, M8 Symbol: A33 Machine
With external pilot specifications (Pitch) P = 10.5 13.5 46.9 18.3 11.8 14.1 8.4 8.6 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 10 19.7 24.6 23 5 3 E 5 3 E 3 5 E 3 5 E 43.2 43 56.5 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 B 2 C2 C2 1 P 1 P 1 P 1 P One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D.: 8 5/16" PE PE X X C1 C1 2 x M12 One-touch fitting [PE: Pilot EXH port] Applicable tubing
max (from 3 of graph MY2H/M3) = 60 (Nm) MX M3 = m3 x g x X = 7.525 x 9.8 x 140.1 x 10-3 = 10.33 (Nm) m3 M3 MTS Load factor 3 = M3/M3 max = 10.33/60 = 0.17 MY 5.
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
PSE541 and PSE543 are remote vacuum sensors with a 1 to 5V analog signal output. The sensor construction optimizes space savings, for tight, constrained spaces. PSE541 is for a low vacuum (-101 to 0 kPa), while PSE543 is for compound pressure (-100 to 100 kPa).
CJ1 CJP Spring CJ2 Lock piston Thread size Bore size (mm) 20, 25, 32 40 Stroke (mm) Pulling force M2.5 x 0.45 x 25l or more 2 4.9 N CM2 M3 x 0.5 x 30l or more 3 10 N Pressure CG1 Remove the bolt for normal operation. It can cause lock malfunction or faulty release. MB Piston rod MB1 Rubber cap 2. Lock piston is pushed up further. CA2 CS1 CS2 2.
Round head screw (M3 x 8) 4 pcs. Enclosed parts Round head screw (M4 x 6) 2 pcs. Round head screw (M3 x 8) 4 pcs. 13 Accessories Series EX600 Reinforcing brace This bracket is used on the bottom of the unit at the intermediate position for connecting 6 units or more. For direct mounting EX600-ZMB1 For DIN rail mounting EX600-ZMB2 Enclosed parts Round head screw (M4 x 5) 2 pcs.
Hexagon socket head cap screw (M3 x 0.5 x 16l) 2 pcs.
1/8" one-touch fitting assembly (Straight) SJ2000-56-1A M3 port block assembly KJH03-C2 5/32" one-touch fitting assembly (Straight) KJH02-C2 2 one-touch fitting assembly (Straight) KJH07-C2 1/4" one-touch fitting assembly (Straight) KJH04-C2 4 one-touch fitting assembly (Straight) KJL01-C2 1/8" one-touch fitting assembly (Elbow type) KJH06-C2 6 one-touch fitting assembly (Straight) SJ3000
16 Hex 13/64 13/64 5/16 Hex Typ. 80 M3-LB4 M3-LB1 M3-LB2 M3-LB3 M3F-LB3 M3-LB2 1/2 1" 15/16 5/8 5/8 5/8 5/16 Hex Typ. 3/16 Hex Typ. 81 M3-T1 M3-T2 M3-T3 M3-T4 M3-T2 1/2 See complete selection of adapters on pages 23 & 24 1/4 5 32 /32 3/16 Hex 7/16 Ref 1/4 Hex 5/16 Hex M3 x 0.5 M6 x 1 Thd .085 5 32 9 32 M3 0.5 Thd to 10-32 Thd .241 Ref 82 M3 x 0.5 to M6 x 1 (F) Adapter M3 Plain Plug M3
x 0.5 thread depth 3.5 10 9 + Stroke 2.7 8 6.7 2-M3 x 0.5 thread depth 3.5 (Piping port) 20 20.5 5.5 Stroke 42 + Stroke 5.5 4.5 13.4 32 + Stroke 5 + Stroke 12 2.75 11 1.2 M3 x 0.5 x 3 L (Hexagon socket head set screw) M8 x 1.25 x 7.5 L (Bolt holder) 0.5 25 0.2 25 0.2 5.3 5.3 16 32 31 2-M3 x 0.5 through 3.4 through 6.5 counterbore with depth 5 (Opposite side: Same) 5.5 2-M3 x 0.5 through