SMC Corporation of America
Elite Part Number Search
Search Results "PFM510S-01-2-A-WV"

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: S (Bracket for w/Flow Adjustment

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: 01 (Rc1/8), Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)

Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/8] 1/8, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Sensor, Monitor Structure: [Separate Type Connector Connection] Separated sensor, Output Method: Analog, Analog Output Specification: Voltage, Pipe Port Type: Female Thread, Plumbing Thread Type: [Rc (R)] Rc, Plumbing Thread Nominal: [1/8] 1/8, Pressure Resistance(MPa): 1, Flow Rate Type: Standard, Operating Temperature Range(°C): -10~60, Operating Humidity Range(%): 35~85, Number of Inputs: 2,

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: Rc1/8, Piping Entry Direction: Straight, Output Specification: 1 [Analog Output (1 to 5 V)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: W [Lead Wire w/Connector (2m) + Rubber Cover], Option: -

D-A59W Bore size (mm) A B A B A B A B A B A B A B A B A B A B A B 40 50 63 80 9 9 5 5 2.5 2.5 4.5 4.5 2 2 5.5 5.5 3 3 10.5 10.5 0 0 1 1 0 0 9.5 8.5 5.5 4.5 3 2 5 4 2.5 1.5 6 5 3.5 2.5 11 10 0 0 1.5 0.5 0 0 12.5 11.5 8.5 7.5 6 5 3 2.5 5.5 4.5 9 8 6.5 5.5 14 13 2.5 1.5 4.5 3.5 3 2 16.5 13.5 12.5 9.5 10 7 7.5 4 9.5 6.5 13 10 10.5 7.5 18 15 6.5 3.5 8.5 5.5 7 4 100 18 16 14 12 11.5 9.5 9 6.5 11

Refer to the Specific Product Precautions for the replacement period. 1517 A CY1L Series Construction Slider type/Ball bushing bearing CY1L6 $0 #9 #3 @2 t #4 !9 #8!0!2!6 @4 @1 @8 #0 #1 $1 w @9 i #2 !1 o q u r y e @6 @5 @3 @7 CY1L10 to 40 @2#9 @0$0 t !9 #5$2 #8 !2 !0 !6!7@4 @1 !8 !4 !5 $0 @8 #7 #6 $1 F G Area G (10) Enlarged view F 10, 15 w u i o !1 #2 q !

We 0 We A L Since there are 2 guides, the guides' central axis and the cylinder's central axis are the same.

0 #4 #3 $7 #7 @4 q i @8 $6 @7 $2 @0 $8 #8 $5 $0 #0 #1 @6 @2 $4 #9 @9 $6 @1 $2 @5 !3 $3 !9 $1 #5 #2 !2 #6 A @3 A Section A-A !7 !8 t !7 Enlarged drawing of shim part !6 y !

A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) 16 (2) (2) (2) B D 20 (2) (2) (2) View from piston rod end 25 (2) (2) (2) 32 C (2) 40 (2) 50 (2) Operating Range Auto Switch Mounting Bracket/Part No. (mm) Reed switch Solid state switch Applicable switch Auto switch model Bore size Bore size (mm) Mounting bracket part no.

7 q @0 u A A i o !9 !6 !9 !1 !5 A-A t y @2 C B e @1 !0 C B r w C-C B-B !4 !2 Body Table !3 Component Parts No. Description Material Note No.

Features 2 Series NCY3B Model Selection Criteria Model selection point Recommended cylinder Appearance Features Non-integrated guide type Series NCY3B Size: 6(1/4"), 10(3/8"), 15(5/8"), 20(3/4"), 25(1"), 32(1-1/4"), 40(1-1/2"), 50(2"), 63(2-1/2") When used with many different types of guides. When a long stroke is necessary. A long stroke is possible.

HB HT HC N X A W K 2 x plug H 2 x P (Piping port) HA CB 4 x counter bore dia.

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Lead Wire w/Connector (2 m), Option: S (Bracket for w/Flow Adjustment Valve)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: S (Yes), Port Size: N01 (NPT1/8), Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: A (w/Calibration Certificate), Connector: Z (w/o Lead Wire w/Connector)

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: Lead Wire w/Connector (2 m), Option: Bracket for w/Flow Adjustment Valve

Flow Rate Range: 10 [0.2 to 10 (5 for CO2) â„“/min], Flow Adjustment Valve: Yes, Port Size: NPT1/8, Piping Entry Direction: Straight, Output Specification: 2 [Analog Output (4 to 20 mA)], Instruction Manual: With Instruction Manual, Calibration Certificate: w/Calibration Certificate, Connector: w/o Lead Wire w/Connector, Option: -

2 !3 CU CQ2B32-PS CQ2B40-PS CQ2B50-PS CQ2B63-PS CQ2B80-PS CQ2B100-PS 32 40 50 63 80 100 Piston Piston rod Collar Snap ring Bumper A Bumper B Bushing Wearing CQS A set includes !1, !2 and !3 CQ2 MU Seal kits are sets consisting of items !1, !2 and !3, which can be ordered using the kit number for each cylinder bore size.

D-Y7WV D-Y7BAL D-A3 D-A44 D-G39 D-K39 D-A5 D-A6 D-A59W D-F5NTL D-F5LF D-P5DWL Bore size (mm) A A A A B A A A A B B B B B B B 32 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 40 12 11 7 4.5 0 0.5 3.5 4 0.5 9.5 8.5 4.5 2 1 1.5 0 50 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 63 12.5 11.5 7.5 5 0 1 4 4.5 1 10 9 5 2.5 1.5 2 0 80 15.5 14.5 10.5 8 2.5 4 7 7.5 4 14 13 9 6.5 5.5 6 2.5 100

A B C D A B C D Bore size (mm) Port aperture A 12 (1) (1) (1) CUJ 16 (2) (2) (2) CU B D 20 (2) (2) (2) View from piston rod end 25 CQS (2) (2) (2) 32 C (2) CQM 40 (2) CQ2 50 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (2) RQ Operating Range Auto Switch Mounting