Flange Foot Note 1) Double clevis Note 2) Bore size (mm) 32 40 50 63 RZQ-F032 RZQ-L032 RZQ-D032 RZQ-F040 RZQ-L040 RZQ-D040 RZQ-F050 RZQ-L050 RZQ-D050 RZQ-F063 RZQ-L063 RZQ-D063 Note 1) When ordering foot brackets, order two pieces per cylinder. Note 2) The following parts are included with each mounting bracket.
Clevis 1 CG-D020 CG-D025 CG-D032 CG-D040 CG-D050 CG-D063 CG-D080 CG-D100 1 clevis, 4 mounting bolts, Pivot bracket 1 clevis pin, 2 retaining rings Pivot bracket 1 CG-020-24A CG-025-24A CG-032-24A CG-040-24A CG-050-24A CG-063-24A CG-080-24A CG-100-24A 1 pivot bracket Note) Order two foots per cylinder.
Open collector (24 VDC, 40 mA) Output type CE2 CQ-L020 CQ-D020 CQ-F020 A/B phase difference output Output signal CQ-L032 CQ-D032 CQ-F032 500 VDC, 50 M or more (between case and 12E) Insulation resistance ML2B CQ-L040 CQ-D040 CQ-F040 33.3 Hz, 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance CQ-L050 CQ-D050 CQ-F050 C J G5-S CQ-L063 CQ-D063
Open collector (24 VDC, 40 mA) CQ-L020 CQ-F020 CQ-D020 Output signal A/B phase difference output CQ-L032 CQ-F032 CQ-D032 50 M or more (500 VDC measured via megohmmeter) (between case and 12E) Insulation resistance CQ-L040 CQ-F040 CQ-D040 CQ-L050 CQ-F050 CQ-D050 33.3 Hz, 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance CQ-L063 CQ-F063 CQ-D063
Bore size (mm) 20 25 32 40 50 63 80 100 2 foots, 8 mounting bolts Note) 2 Foot CG-L025 CG-L032 CG-L020 CG3-L040 CG-L050 CG-L063 CG-L080 CG-L100 1 flange, 4 mounting bolts 1 clevis, 4 mounting bolts, 1 clevis pin, 2 retaining rings 1 CG3-F020 CG3-F025 CG3-F040 Flange CG-F032 CG-F050 CG-F063 CG-F080 CG-F100 1 CG-D020 CG-D025 CG-D032 CG3-D040 CG-D050 CG-D063 CG-D080 CG-D100 Clevis Pivoting bracket
Bore size (mm) Foot (1) Flange (3) 50 CQ2X50-PS Double clevis 63 DCQ2X63-PS Gasket: 1 pc. 32 40 50 63 80 100 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 80 CQ2X80-PS Grease pack (10 g): 1 pc. -X 100 CQ2X100-PS Pneumatic Circuit 2.
Open collector (24 VDC, 40 mA) Output type CE2 CQ-L020 CQ-D020 CQ-F020 A/B phase difference output Output signal CQ-L032 CQ-D032 CQ-F032 500 VDC, 50 M or more (between case and 12E) Insulation resistance ML2B CQ-L040 CQ-D040 CQ-F040 33.3 Hz, 6.8 G 2 hrs. each in X, Y directions 4 hrs. in Z direction based upon JIS D 1601 Vibration resistance CQ-L050 CQ-D050 CQ-F050 C J G5-S CQ-L063 CQ-D063
Bore size (mm) Foot (1) Flange (3) 50 CQ2X50-PS Double clevis 63 DCQ2X63-PS Gasket: 1 pc. 32 40 50 63 80 100 CQ-D032 CQ-D040 CQ-D050 CQ-D063 CQ-D080 CQ-D100 CQ-F032 CQ-F040 CQ-F050 CQ-F063 CQ-F080 CQ-F100 CQ-L032 CQ-L040 CQ-L050 CQ-L063 CQ-L080 CQ-L100 80 CQ2X80-PS Grease pack (10 g): 1 pc. -X 100 CQ2X100-PS Pneumatic Circuit 2.
Flange Foot Note 1) Double clevis Note 2) Bore size (mm) 32 40 50 63 RZQ-F032 RZQ-L032 RZQ-D032 RZQ-F040 RZQ-L040 RZQ-D040 RZQ-F050 RZQ-L050 RZQ-D050 RZQ-F063 RZQ-L063 RZQ-D063 Note 1) When ordering foot brackets, order two pieces per cylinder. Note 2) The following parts are included with each mounting bracket.
size (mm) Foot (1) Flange Double clevis 0.3 0.5 0.7 71 94 113 147 181 241 317 377 495 589 841 935 1360 1510 2140 2360 118 157 189 245 302 402 528 628 825 982 1400 1560 2270 2510 3570 3930 165 220 264 344 422 563 739 880 1150 1370 1960 2180 3170 3520 5000 5500 IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT IN OUT 20 25 32 40 50 63 80 100 CLQ-D020 CLQ-D025 CLQ-D032 CLQ-D040 CLQ-D050 CLQ-D063
Bore size (mm) Operating direction Operating pressure (MPa) Note 3) Note 1) Bore size (mm) Foot Flange Double clevis 0.3 181 241 317 377 495 589 841 935 0.5 302 402 528 628 825 982 1400 1560 0.7 422 563 739 880 1150 1370 1960 2180 IN OUT IN OUT IN OUT IN OUT 32 40 50 63 CLQ-D032 CLQ-D040 CLQ-D050 CLQ-D063 CLQ-F032 CLQ-F040 CLQ-F050 CLQ-F063 CLQ-L032 CLQ-L040 CLQ-L050 CLQ-L063 32 40 Note 1
Prefix: CG (Selection for "T" Mount 25 & 32mm Bore), Mounting: D (Double Clevis), Applicable Bore: 063 (2 1/2")
Mounting: D (Double Clevis), Applicable Bore: 63mm
Mounting: D (Double Clevis), Applicable Bore: 63mm
Mounting: Double Clevis, Applicable Bore: 63mm
Prefix: Selection for "T" Mount 25 & 32mm Bore, Mounting: Double Clevis, Applicable Bore: 2 1/2"
Model: CQ, Mounting: Double Clevis, Applicable Bore: 63mm
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
Part Number Description: CLEVIS REAR DOUBLE Product Line: A Product Line Description: ACTUATOR Family Code: 515 Family Description: CQ2 COMPACT CYLINDER Class Code: P2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number
Part Number Description: CLEVIS DOUBLE Product Line: A Product Line Description: ACTUATOR Family Code: 420 Family Description: CG ROUND BODY CYLINDER Class Code: P2 Part Code: 2 Reference Code: E This is a custom made item that is NOT returnableClick here to report information errorImage shown may not match exact part number