(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
Extension Locking, Rubber Bumper Retraction Locking, Rubber Bumper 1000 1000 100 100 80 100 80 100 Load mass (kg) Load mass (kg) 63 63 10 10 50 50 40 40 25 32 25 32 1 1 20 20 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 0.1 0.1 100 500 Maximum speed (mm/s) 100 500 Maximum speed (mm/s) Allowable Load Mass Horizontal (Without switch) Horizontal (With switch) 30 30 10 10 100 100 80 Load mass m (kg) Load
To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
To adjust the cylinder speed, use a speed controller. 30 20 CXW32 10 CXWL25 CX2N25 Load mass (kg) CXW20 CX2N25-B, CXWM25 5 CXW16 4 CX2N15-B CX2N15 3 2 CX2N10-B CX2N10 CXW10 1 0.5 10 50 100 200 300 500 1000 Cylinder speed (mm/s) 462 Series CX2 Prior to Use 1. Changing from the non-auto switch specifications to the auto switch specifications 2.
200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 Intermediate strokes and short strokes other than the above are produced upon receipt of order.
MK2T Max. piston speed Average piston speed Note 1) Total stroke Note 2) Stroke time Note 3) Model MK 115 mm/s 72 mm/s 25 mm 0.35 seconds CK1 1.0 x 104 Note 1) Average piston speed = Max. piston speed 1.6 Note 2) Total stroke = Clamp stroke + Rotary stroke Note 3) Total stroke Average piston speed The stroke time should be longer than the above mentioned stroke time. 115 200 CLK2 10 100 1000
V(mm/s) = x 1000 In case of high pison speed, the use of an auto switch (DF7NT and G5NT) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Keep wiring as short as possible.
V (mm/s) = Auto switch operation range (mm) Load operating time (ms) x 1000 In cases of high piston speed, the use of an auto switch (D-F5NT, F7NT, G5NT and M5T) with a built-in OFF delay timer (approx. 200ms) makes it possible to extend the load operating time. 4. Wiring should be kept as short as possible.
If operated beyond the limiting ranges, excessive impact will occur and this may cause damage to equipment. 100 Lateral load F (N) 80 10 CUJ 63 CU 50 CQS Operating pressure 0.5 MPa Operating pressure 0.4 MPa Graph (1) 40 32 25 CQ2 1000 20 1 10 100 300 RQ Stroke + Eccentric distance (mm) CQM Cushion Needle Adjustment Caution 100 MU 100 Load mass kg 80 63 50 1.
When bank 2 is selected Decimal no. 1 2 3 4 5 6 7 8 9 0 BCD 0 0001 0010 0011 0100 0101 0110 0111 1000 1001 16 17 18 19 20 Bank 2 Bank 3 Bank 4 11 12 13 14 15 Ex.) 1294.53 is expressed as follows. 0001 0010 1001 0100 0101 0011 6 7 8 9 10 Bank 1 1 2 3 4 5 RS-232C 1 2 3 4 5 Output terminal 6 7 8 9 10 Preset no.
IC circuit 5 V A76H A96V A96 Yes No A72 A73 A80 A72H A73H A80H 200 V Solid state switch Reed switch Grommet 100 V 12 V IC circuit A90V A93V A90 A93 5 V, 12 V 12 V 12 V Relay, PLC 2-wire No Yes 24 V A73C A80C A79W F7NV F7PV F7BV J79C F7NWV Connector IC circuit 5 V, 12 V Grommet Diagnostic indication (2-color indication) Yes 3-wire (NPN) 3-wire (PNP) F79 F7P J79 M9NV M9PV M9BV M9N M9P M9B 5
D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads.
D-A72(H) must be used with the contact protection box regardless of load types and lead wire length since it is greatly affected by loads.
Outside of cylinder tube with hard chrome plated 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 Auto switch rails on both side faces (with 2 pcs.) 1500 Made to Order Specifications Click here for details 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 40 1500 Symbol Specifications -XB9 -XB13 -XB22 Low speed cylinder (15 to 50 mm/s) Note) Intermediate stroke
The maximum detectable piston speed is: Auto switch operating range (mm) _ Time load applied (ms) Operating current of load (OFF condition) > Leakage current V(mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
If the center of gravity of the total load is not in the center of the shaft, provide a balance weight as illustrated below so that moment in the rotational direction would not be applied to the tip of the piston rod. 0.3 0.2 0.3 0.2 0.7 1 0.5 0.4 Load rate () Graph 2 Cylinder output on the retracting side (Double acting) 1500 150 Tube bore size [mm] 1000 100 40 400 500 40 50 32 200 250 300
V (mm/s) = Auto switch operating range (mm) Load operating time (ms) x 1000 In case of high piston speed, the operating time of the load can be extended by using an auto switch (D-F7NT) with built-in OFF delay timer (approx. 200ms). 4. Keep wiring as short as possible.
JIS B 8370: JIS B 8361: JIS B 9960-1: -(1 :) JIS B 8433-1993:*2) 1. 2. 3. 1. 2. 3. 4. 1 1 1 1 1 1.5 1.5 1.5 1.5 *3) *3) *3) *3) 1 1 1 1 1 1 1 1 () 2 , 2 2 2 2 3 , , ,, 4 , , , , , , , , , , , , 5m [] ,, , , , , , , , 5 ,, , , , , , , , , , , , , , 6 , 2 ,40mm, ON ON ON ON , ,: 1000 (ms) (mm) V(mm/s) = <> ,,(ON ) ,5m , ,30m, , <> ,100m <> (D-A96A96V ) ,,( ) [n ,n ] ,, ,, ,D-A90,A90V
The maximum detectable piston speed is: Auto switch operating range (mm) _ Load operating time (ms) Operating current of load (OFF condition) > Leakage current V (mm/s) = x 1000 If the criteria given in the above formula are not met, it will not reset correctly (stays ON). Use a 3 wire switch if this specification will not be satisfied.
load Pre-wire Type Special function Electrical entry Wiring (Output) 0.5 (Nil) 3 (L) 5 (Z) None (N) DC AC connector Perpendicular In-line Perpendicular In-line 3-wire (NPN equivalent) 5 V IC circuit A76H A96V A96 Grommet Reed switch Solid state switch A93 M9N M9P M9B F9NW F9PW F9BW F9BA A93V M9NV M9PV M9BV F9NWV F9PWV F9BWV 200 V A72H A73H F79 F7P J79 F79W F7PW J79W F7BA F79F A72