SMC Corporation of America
Elite Part Number Search
Search Results "NCDY2S15H-1000-A80"

750 CY3B CY3R 20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 CY1S 25 1200 32 CY1L 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 CY1H 50 63 CY1F Note 1) The longer the stroke, the larger the amount of deflection in a cylinder tube.

20 ~ 1000 32 35 70 52 20 40 17 17 M 8 x 1.25 7 11 M 18 x 1.5 30 3/8 90 0 63 ~ 1000 20 ~ 1000 32 35 85 64 20 40 17 17 M 10 x 1.25 7 14 M 18 x 1.5 31 3/8 98 0 80 ~ 1000 20 ~ 1000 37 40 102 78 25 52 21 21 M 12 x 1.75 11 17 M 22 x 1.5 37 1/2 116 0 100 ~ 1000 20 ~ 1000 37 40 116 92 30 52 21 21 M 12 x 1.75 11 17 M 26 x 1.5 40 1/2 126 0 Without gaiter With gaiter Bore Size (mm) FV FD FT FX FY FZ

Extension Locking, Rubber Bumper Retraction Locking, Rubber Bumper 1000 1000 100 100 80 100 80 100 Load mass (kg) Load mass (kg) 63 63 10 10 50 50 40 40 25 32 25 32 1 1 20 20 0.5 MPa 0.4 MPa 0.5 MPa 0.4 MPa 0.1 0.1 100 500 Maximum speed (mm/s) 100 500 Maximum speed (mm/s) Allowable Load Mass Horizontal (Without switch) Horizontal (With switch) 30 30 10 10 100 100 80 Load mass m (kg) Load

Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.

(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).

Up to 600 601 to 1000 Up to 750 751 to 1000 Up to 750 751 to 1000 Long stroke The minimum stroke of the one with rod boot is 20 mm or more.

Up to 600 601 to 1000 Up to 750 751 to 1000 Up to 750 751 to 1000 30 35 35 40 40 27 32 32 37 37 60 70 85 102 116 22 27 27 32 41 44 52 64 78 92 16 20 20 25 30 32 40 40 52 52 10 10 10 14 14 6 7 7 11 11 9 9 11.5 13.5 13.5 40 45 50 65 75 86 83 83 84 85 138 144 166 204 212 3.2 3.2 3.2 4.5 6 42 50 59 76 92 70 80 93 116 133 M8 x 1.25 M8 x 1.25 M10 x 1.25 M12 x 1.75 M12 x 1.75 8 11 11 13 16 Bore

MB1 CA2 Contact Protective Box/Internal Circuit CS1 CD-P11 Operating Range of Auto Switch (mm) C76 Brown lead wire Bore Surge absorber Choke coil Model Mounting 32 40 C85 Blue lead wire 8 D-C7/C80/C73C/C80C 8 5 D-H7/H7W/H7BAL 4.5 Band C95 10 9 D-H7C CD-P12 D-A7/A80/A7H/A80 8 8 CP95 (+) Brown lead wire Choke coil D-A73C/A80C 14 13 D-A79W Rail NCM () Blue lead wire D-F7/J79/F7W/J79W 6.5 6 D-F7V

MB1 CA2 Contact Protective Box/Internal Circuit CS1 CD-P11 Operating Range of Auto Switch (mm) C76 Brown lead wire Bore Surge absorber Choke coil Model Mounting 32 40 C85 Blue lead wire 8 D-C7/C80/C73C/C80C 8 5 D-H7/H7W/H7BAL 4.5 Band C95 10 9 D-H7C CD-P12 D-A7/A80/A7H/A80 8 8 CP95 (+) Brown lead wire Choke coil D-A73C/A80C 14 13 D-A79W Rail NCM () Blue lead wire D-F7/J79/F7W/J79W 6.5 6 D-F7V

10.7 MPa Minimum operating pressure Rubber bumper 0.12 MPa 0.06 MPa Air cushion 0.1 MPa CJ1 CJP Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C Cushion Rubber bumper Rubber bumper/Air cushion Lubrication Not required (Non-lube) Air cushion Rubber bumper Symbol CJ2 CJ2 JCM Piston speed Rubber bumper 50 to 750 mm/s Air cushion 50 to 1000

Hs A B A B Auto switch mounting height mm Proper auto switch mounting position mm D-A7H D-A80H D-F7 D-J79W D-F7BAL D-F7F D-F7NTL D-A7H, A80H D-A73C, A80C D-F7, F7V D-F79F, J79 D-J79C, F7W D-F7WV, J79W D-F7BAL, F7BAVL D-F7V D-A73C D-A80C D-A7 D-A80 D-J79C D-A79W Bore size (mm) D-F7WV D-F7LF D-A79W D-F7NTL D-A7, A80 Bore size (mm) D-J79 D-F7W D-F7BAVL Hs Hs Hs Hs Hs Hs 20 B A B A B A B A B

(mm) Auto switch model Hw 23 Hs 12.5 Ht 15 Auto switch model Hw 23 Ht 15 Hv 10.5 D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C D-F7LF Note 2) 2 magnets for auto switches are equipped to the

(mm) Auto switch model Hw 23 Hs 12.5 Ht 15 Auto switch model Hw 23 Ht 15 Hv 10.5 D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C D-A7, D-A80 D-F7, D-J79, D-J79W, D-F7W, D-F79F, D-F7BAL, D-F7NTL D-A7H, D-A80H D-A73C, D-A80C D-F7V, D-F7WV, D-F7BAV D-J79C D-F7LF Note 2) 2 magnets for auto switches are equipped to the

Bore size (mm) Auto switch model 12 to 25 32 40 to 100 D-A7l/A80 D-A73C/A80C D-A7lH/A80H D-A79W D-F7l/J79 D-F7lV D-J79C D-F7lW/J79W D-F7lWV D-F7BAL/F7BAVL D-F79F/F7NTL BQ-1 BQ-2 Auto Switch Mounting Bracket/Weight Mounting bracket part no.

The detection position can be changed under the conditions described in step e. : 2. 3. 4. 5. 350 Rotary Cylinder With Auto Switch Series MRQ Auto Switch Mounting Dimensions Reed switch D-A7/A80 D-A7H D-A73C/A80C CRB2 (In parentheses) are the dimensions of A72.

0 200 400 600 800 1000 1200 1400 1600 Stroke [mm] Stroke [mm] (1 Kg = 2.2 lbs) [Graph 7] Allowable load mass by stroke 40 100 y, z + A = 0 y, z + A = 50 Load mass [kg] y, z + A = 100 y, z + A = 200 10 y, z + A = 300 1 0 200 400 600 800 1000 1200 1400 1600 If load center of gravity exceeds the value of y, z + A on the graph, please consult SMC.

Specifications Bore size (mm) Series Maximum manufacturable stroke (mm) Series Bore size (mm) Maximum manufacturable stroke (mm) CJ1 Applicable Series CJ2 CA2, CBA2 10, 16 40 to 100 300 (Maximum 150 on one side) 1000 CM2 20 to 40 125, 140 1000 1000 CJP Series Vol. no.

CY1H25 (Nm) 64 56 50 40 30 50 40 M1 1.5 10 13 M2 2.5 16 16 M3 1.5 10 13 M1 28 56 64 M2 26 85 96 M3 28 56 64 Model CY1H25 CY1HT25 CY1HT32 Model CY1H10 CY1H15 CY1H20 30 28 26 20 20 CY1H20 CY1H15 16 13 Moment Nm Moment Nm 10 10 2 2.5 3 4 5 3 4 5 CY1H10 M3 2 CY1H10 1.5 1 1 0.5 0.5 70 100 300 500 100 300 500 1000 1000 70 M1 M2 Piston speed mm/s Piston speed mm/s Graph (3) Graph (2) Moment generated

Please contact us for the latest version.sales@ocaire.com, SWITCH RAIL (NCDY2S15H), ACTUATOR, NCY2S GUIDED CYLINDER, G1, 15MM NCY2S PART, .26400 lb

HS 9 Plate Cylinder with Lock Series MLU Proper auto switch mounting position Auto switch mounting height (mm) Auto switch model (mm) D-A7H D-A80H D-F7 D-F7 V D-J79 D-F7W D-F7WV D-J79W D-F7BAL D-F7BAVL D-F79F D-A7H D-80H D-F7 D-J79 D-F7W D-79W D-F7NTL D-F7F D-F7BAL D-A73C D-A80C D-J79C D-A79W D-F7LF D-P5DWL D-F7V D-F7WV D-F7BAVL D-J79C D-A79W D-A7 D-A80 D-F7NTL D-A7 D-A80 D-A73C D-A80C D-P5DWL