SMC Corporation of America
Elite Part Number Search
Search Results "NCDMKB075-0100-M9NSDPCS"

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7A1--Solid State, Gen. Purpose, 3 Wire NPN, Lead Wire, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 5m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: C73--Reed, DC Volt >5 <24, AC Volt <100, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: -, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: B53--Reed, DC Volt >5 <24, LED, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 1 pc., Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: C73C--Reed, DC Volt >5 <24, LED, Connector, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7PW--Solid State, 2-color Indication, 3 Wire PNP, 0.5M, Lead Wire or Prewired Connector: 5m, Number: -, Speed Control Type: -, Applicable Tubing: -, Suffix: -

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: H7A2--Solid State, Gen. Purpose, 3 Wire PNP, Lead Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control

Magnet: Built-in, Mounting: Basic, Bore Size: 3/4 Inch, Stroke: 1 Inch, Cushion: No Cushion, Auto Switch: A93--Reed, DC Volt, AC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Right Angle, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control

Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Travel multiplying factor 0300: 1000 0200: 100 0100: 10 0: 1 0010h Current alarm (warning) reading Reads the alarm No. or warning No. occurring currently. 0 0 Occurring alarm No.

Example: Part Number *NVSA 4114-52AM =A |NVSA 4114.00A vatve mounled on *ISPA 0112 subplate with a #SPA 0100 Interlace Spaed Control between.

[PA04] = 0100. Set the "PA04" to "0100" in the "Basic" tab. Click on the "Single Axis Write" button. Turn the power OFF and ON again. Parameter is enabled. -24- 6.3.6 Absolute position detection system *If you use the absolute position detection system, set parameter: [PA03]=0001. Refer to "LECSS Operation Manual, chapter 12 for details.

Bearing Type: M (Slide bearing), Bore Size: 50mm, Port Type: Bore 12-16: M5x0.8; Bore 20-100: Rc, Stroke: 100mm, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: SDPC (0.5m Cord Length, M12-4 Pin Connector), Number: S (1 pc.)

Cylinder (Tube) Inner Diameter(φ): 12, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard / With rod detent function, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Operating Pressure(MPa): -, Cushion: Rubber bumper at both ends, Port thread type: M5 x