Cylinder (Tube) Inner Diameter(φ): 2", Stroke(mm): 6", Auto Switches: Without auto switch, Lead Wire Length(m): N/A, The number of the switches: N/A, Type of Auto Switch Mounting: N/A, Custom-made Specifications: Stainless Steel Rod, Dimensional interchange to other manufacturer's magnetic reed switch cylinders
Magnet: Built-in, Mounting: Basic, Bore Size: 2", Stroke: 6in, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: H7BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: 5m, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Universal, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed Control
Magnet: Built-in, Mounting: Basic, Bore Size: 2", Stroke: 6in, Cushion: No Cushion, Rod Boot: Without Boot, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Speed Control Type: Universal, Applicable Tubing: 1/4", Suffix: Required Selection w/Speed
Series NCM stainless steel cylinder offers space savings, high performance, and interchangeability with other stainless steel cylinders. A wear ring extends the seal life and a bronze rod bushing is standard on all bore sizes. The NCM is available in 4 mounting styles * as well as double rod and spring return or spring extend models. The NCM is auto-switch capable without any change in cylinder
Magnet: D (Built-in), Mounting: B (Front Nose Mount), Bore Size: 200 (2"), Stroke: 0600 (6"), Cushion: None, Auto Switch: M9BA--Solid State, Water Resist., 2 Wire, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Temperature Option: Standard, Stainless Steel Option: X6009 (All Stainless Steel)
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Custom-made Specifications: None
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen.
Series: NCDA1 (Standard w/ Magnet), Mounting: R (MS4, Side Tapped), Bore Size: 325 (3 1/4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Series: NCDA1 (Standard w/ Magnet), Mounting: D (MP2, Detachable Rear Clevis), Bore Size: 200 (2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen.
Cylinder (Tube) Inner Diameter(φ): 4", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 2 1/2", Stroke(mm): 6", Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: -, Environment, Applications: Standard, Auto Switches: M9P, Lead Wire Length(m): 1, The number of the switches: 2, Type of Auto Switch Mounting: DPC, Custom-made Specifications: None
Magnet: D (Built-in), Mounting: F (Front Flange), Cushion: A (Air Cushion), Bore Size: 20 (3/4"), Stroke: 0600 (6"), Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Series: NCDA1 (Standard w/ Magnet), Mounting: X (MP1, Double Rear Clevis), Bore Size: 250 (2 1/2"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen.
Series: Standard w/ Magnet, Mounting: MP2, Detachable Rear Clevis, Bore Size: 4", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MS4, Side Tapped, Bore Size: 3 1/4", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -, X Option: -
Series: Standard w/ Magnet, Mounting: MP2, Detachable Rear Clevis, Bore Size: 2", Stroke: 6", Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: -, X Option: -
Series: NCDA1 (Standard w/ Magnet), Mounting: G (MF2, Rear Flange), Bore Size: 400 (4"), Stroke: 0600 (6"), Air Cushion / Rod Boot: Both Ends (Air Cushion), Thread: Nil (Small Male, Standard, Threaded), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: MDPC (1.0m Cord Length, M12-4 Pin Connector)
Magnet: Built-in, Mounting: Double Rear Clevis, Bore Size: 2 1/2", Stroke: 6", Option: Both Ends (Air Cushion), Adjustment Range: Not Applicable, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 1.0m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), X Option: None, Speed Control Type: Right Angle, Applicable
Step Request data Response data Operation details 01 10 0600 000A Alarm history command to clear alarm 14 0 0 0 0 1 01 10 0600 000A history sent. (0 to 10 entries) 0 0 0 0 0 0 01 10 060A 000A Alarm history command to clear alarm 14 0 0 0 2 01 10 060A 000A history sent. (11 to 20 entries) 0 0 0 0 0 0 0 67 - Caution Ensure the alarm history is cleared only after taking corrective action in