Cylinder speed-1000 mm/sec. Sequencer response time-0.1 sec. Detecting point despersion-Within 100mm (=1000 mm/sec. X 0.1sec.) Take PLC response time into consideration when using.

20 1000 1500 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1500 2000 32 40 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 2000 1500 50 63 Note) Contact SMC if the maximum stroke will be exceeded.

D-A90(V) OUT() Brown Contact protection box CD-P11 CD-P12 Reed switch OUT() Blue Weight (g) D-A93(V) Model D-A90 D-A90V D-A93 D-A93V D-A96 D-A96V LED Brown OUT (+) Brown 41 Lead wire length (m) 0.5 6 6 6 6 8 8 Contact protection box CD-P11 CD-P12 Resistor 3 30 30 30 30 41 Reed switch Zener diode Dimensions (mm) OUT () Blue Blue D-A90/D-A93/D-A96 2 2.8 4.5 2.7 D-A96(V) DC (+) Brown 4 LED

(between lead wire and case) 1000 VAC for 1 min.

(between lead wire and case) 1000 VAC for 1 min.

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

Stroke (mm) Up to 10 Up to 30 Up to 50 Up to 75 Up to 100 Up to 1000 Up to 800 Up to 1000 Up to 1000 Up to 800 Up to 1000 Up to 1000 Max. speed (mm/s) 20 Selection graph (6) (7) (8) (9) (10) (11) (12) 25 32 Caution If the cylinder is horizontally mounted and the plate end does not reach the load's center of gravity, use the formula below to calculate the imaginary stroke l that includes the

(V), D-A93(V), D-A96(V) Auto Switch Specifications Grommet Electrical entry direction: Side D-A90, D-A90V (without indicator light) D-A90, D-A90V Auto switch part no.

) (900) (1000) (900) (1000) (1000) MY1C20 MY1C20 MY1C20 MY1C20 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 (900) (900) 20 10 0 1000 2000 3000 5000 4000 Support spacing (l ) (mm) 8-11-65 63 Series MY1C Construction: 16 to 63 $1 #3 !

x 1.5 Up to 1000 19 G 1/2 25 32 55 40 398 65 15 17 6 160 20 58 27 M27 x 2 13 M12 x 1.75 19 Up to 1000 G 1/2 32 40 60 54 Minimum stroke for trunnion mounting are below.

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

Support brackets are not for mounting; use them solely for providing support. (1400) (1400) (1400) (1400) (1400) (1400) MY1CW40 MY1CW40 MY1CW40 50 50 MY1MW32 MY1MW32 MY1MW32 MY1CW32 MY1CW32 (1100) (1100) (1100) (1100) 40 40 (1200) (1200) (1200) (1200) (1200) (1200) MY1MW25 MY1MW25 MY1MW25 MY1CW25 MY1CW25 MY1CW25 30 (1000) (1000) (1000) (1000) 30 MY1MW20 MY1MW20 MY1MW20 (1000) (900) (1000)

/s Piston speed mm/s 4 Series MY2 Maximum Allowable Moment/Maximum Load Weight Moment/MY2H (Single axis) MY2H/M3 MY2H/M1 MY2H/M2 50 60 50 60 50 60 30 30 30 20 20 20 Moment Nm Moment Nm Moment Nm MY2H40 MY2H40 10 10 10 MY2H40 MY2H25 MY2H25 MY2H25 5 5 5 4 4 4 3 3 3 2 2 2 MY2H16 MY2H16 MY2H16 1 1 1 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 100 200 300 400500 1000 1500 Piston

1000 1500 Minimum Operating Pressure 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 25 1200 1500 32 1500 2000 0.2 100, 150, 200, 250, 300, 350 400, 450, 500, 600, 700, 800 900, 1000 Minimum operating pressure (MPa) 0.16 0.16 40 1500 2000 0.14 0.15 0.12 0.15 Note 1) Contact SMC if the maximum stroke will be exceeded.

L1 L2+A5 L3 2 1 W V 2 E= ( ) 2 9.8 1000 Collision speed V=1.4 Va *) Corrected coeficient 1 420 E= 1( ) =0.088 2 1000 V=1.4 X 300=420 Calculate kinetic energy E (J) of work. Calculate allwable kinetic energy Ea (J). Check that kinetic energy of work does not exceed allowable kinetic energy.

Examine for My My=10(10+30)/1000=0.4 A3=30 Examine for My My=10(30+10)/1000=0.4 A6=10 M=W(Ln+An)/1000 Corrected value for center position distance of moment An: Table 3 Calculate allowable static moment Ma(Nm) Ma=K Mmax Work mounting coeficient K: Fig.3 Allowable moment coeficient : Graph 2 Max. allowable moment Mmax: Table 4 2=M/Ma May=1 x 1 x 15.9=15.9 Mymax=15.9 K=1 =1 2=0.4/15.9=0.0252

(V), D-A93(V), D-A96(V) Specifications D-A96 D-A90 In-line D-A90V D-A93 In-line D-A93V In-line D-A96V Auto switch part no.

1500 0 500 1000 1500 Flow rate L/min (ANR) Flow rate L/min (ANR) AR40-A Rc1/2 AR40-06-A Rc3/4 0.6 0.6 0.5 0.5 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 1000 2000 3000 4000 0 0 1000 2000 3000 Flow rate L/min (ANR) Flow rate L/min (ANR) 183 Regulator Series AR10-A to AR40-A Pressure Characteristics (Representative values) Conditions: Inlet pressure 0.7