Name Type Value 0 1 Bit0 Bit1 Bit2 Bit3 Bit4ON/OFF Bit5 Bit6() Bit7(/) 01h0Ah 64h83h 2 Get Ch031 BYTE 1 101h0Ah 09 264h83h 031 -73No.EX-OMS0026CN (Class:78h) Instance Attribute Access Name Type Value () BOOL 0 1 64h / // () BOOL 0 1 65h SI / 66h / BOOL 0 1 67h / BOOL 0 1 68h / BOOL 0 1 BOOL 0 1 69h SI / 00.1 ms 11 ms 210 ms 320 ms 01h0Ah Get/Set 6Ah 1 / USINT 01 ms 115 ms 2100 ms 3200
0.0176575 0 [Calculation example] (1) Conversion from the process data to the flow measurement value (For PF2MC7 series, unit L/min, flow range 1000 L and PD = 2500) Pr = a (PD) + b = 0.25 2500 + 0 = 625 [L/min] (2) Conversion from the flow measurement value to the process data (For PF2MC7 series, unit L/min, flow range 1000 L and Pr = 800 [L/min]) (PD) = (Pr b) / a = [800 0] / 0.25 = 3200
0.0176575 0 [Calculation example] (1) Conversion from the process data to the flow measurement value (For PFMC7 series, unit L/min, flow range 1000 L and PD = 2500) Pr = a (PD) + b = 0.25 2500 + 0 = 625 [L/min] (2) Conversion from the flow measurement value to the process data (For PFMC7 series, unit L/min, flow range 1000 L and Pr = 800 [L/min]) (PD) = (Pr b) / a = [800 0] / 0.25 = 3200
Air-Cooled refrigerated type Water-Cooled refrigerated type Refrigerant R407C(HFC) Quantity of refrigerant kg 0.57 0.5 Control method PID control Ambient temperature and humidity2 Temperature: 5 to 40oC Humidity: 30 to 70% Circulating fluid3 Tap water, Ethylene glycol aqueous solution 15%5 Operating temperature oC 5 to 40 range2 Circulating fluid system Cooling capacity4 (50/60Hz) W 2600/3200
.: 25oC 1) Cooling capacity 1600 1400 Facility water 10oC Facility water 25oC 1200 Cooling capacity W 1000 Facility water 35oC 800 600 400 200 0 0 10 20 30 40 50 60 70 Recirculating fluid temp. oC Fig.9-11 Cooling capacity (HED007) 2) Heating capacity 3200 2800 2400 Heating capacity W Facility water 35oC 2000 1600 Facility water 10oC 1200 Facility water 25oC 800 400 0 0 10 20 30 40 50 60
H5 Initial power / Power consumption (W) 100 VAC 200/40 400/70 400/80 600/130 800/180 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
60S-1 XL1A25-60S-1 1 1 H4 AC100V 200/40 200/50 / AC200V 800/40 800/50 XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 1 1 1 H5 AC100V 200/40 400/70 400/80 / AC200V 800/40 1600/80 1600/80 XLA-63-2 XLA-80-2 AC90240V XL1A25-60S-2 XL1A25-60S-3 1 1 H4 AC100V 400/100 600/150 / AC200V 1600/100 2400/150 XL1A25-60S-3 XL1A25-60S-2 1 2 H5 AC100V 600/130 800/180 / AC200V 2400/130 3200
H5 Initial power / 100 VAC 200/40 400/70 400/80 600/130 800/180 Power 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
H5 Initial power / Power 100 VAC 200/40 400/70 400/80 600/130 800/180 200 VAC 800/40 1600/80 1600/80 2400/130 3200/180 consumption (W) Note 1) Initial power and power consumption are nominal values. Note 2) Heaters are not available for size 16.
Operation/ Shutdown 3.10.6 PID manual setting CH1 PID (control parameter) P Proportion band (050) i Integral time (051) d Derivative time (052) PID(proportion band / integral time / derivative time) is manually set. [ Setting range] P: 0.1 to 999.9 I: 0 to 3200 sec. D: 0.0 to 999.9 sec. PID values are automatically set by auto tuning.
motor HF-MP HF-KP 1) or LE-CSE-SB LE-CSE-RB MR-J3ENCBL M-A2-L MR-J3ENCBL M-A2-H 2) Servo Motor LE-Servo motor HF-MP HF-KP CN2 1) Cable model 1) For CN2 connector 2) For encoder connector Connector set: 54599-1019(Molex) Connector: 1674320-1 Crimping tool for ground clip: 1596970-1 Crimping tool for receptacle contact: 1596847-1 (Tyco Electronics) Receptacle: 36210-0100PL Shell kit: 36310-3200
AK ASS ASR ASF 15-9-25 3 Series AS Construction: AS1400-M3 Construction: AS1200-M3, AS120-M5, AS220/320/420 AS2200, 3200, 4200 Meter-out type AS1200-M3, M5, U10/32 Component Parts No.
AK ASS ASR ASF 15-9-25 3 Series AS Construction: AS1400-M3 Construction: AS1200-M3, AS120-M5, AS220/320/420 AS2200, 3200, 4200 Meter-out type AS1200-M3, M5, U10/32 Component Parts No.
Do not drop, bump or apply excessive impact (3200 ft/s2 (980 m/s2)) when handling. Even if the switch body is not damaged, the switch may suffer internal damage that will lead to malfunction. 1. Incorrect wiring can cause the switch to be damaged or malfunction. Connections should only be made when the power supply is turned off. 2.
MHS, Parrallel Style Air Gripper, GRIPPER, 3200 lb
Please contact us for the latest version.sales@ocaire.com, SEAL KIT TVRNC-3200, ACTUATOR, GRIPPER, NC, 50MM GRIPPER, .00000 lb
Tamper-Resistant Type Available T E C H N I C A L SPECIFICATIONS D I M E N S I O N S (N)AS1200-M3 E L B O W T Y P E S Y M B O L S 1.5MPa / 220PSI Proof Pressure 1MPa / 145PSI Maximum Operating Pressure 0.1MPa / 14.5PSI Minimum Operating Pressure 5 ~ 60C / 40~140F Ambient and Fluid Temperature 8 Turns Number of Needle Rotations H O W T O O R D E R (N)AS1000-4000 D I M E N S I O N S (N)AS1200, 2200, 3200
Tamper-Resistant Type Available T E C H N I C A L SPECIFICATIONS D I M E N S I O N S (N)AS1200-M3 E L B O W T Y P E S Y M B O L S 1.5MPa / 220PSI Proof Pressure 1MPa / 145PSI Maximum Operating Pressure 0.1MPa / 14.5PSI Minimum Operating Pressure 5 ~ 60C / 40~140F Ambient and Fluid Temperature 8 Turns Number of Needle Rotations H O W T O O R D E R (N)AS1000-4000 D I M E N S I O N S (N)AS1200, 2200, 3200
AXT632-69-1 AXT632-69-2 VVCA40-3A-06-2 VVCA40-3A-06-1 OR-3200-200-H VCA45--VVCA40-6-n VVCA40-4A-06-2 VVCA40-4A-06-1 Material Mounting screw (side port) Mounting screw (side port) q q Steel Steel Mounting screw (front port) Mounting screw (front port) End plate assembly (D side, side port) End plate assembly (D side, side port) w w Aluminum Aluminum End plate assembly (D side, front port)
AXT632-69-1 AXT632-69-2 VVCA40-3A-06-2 VVCA40-3A-06-1 OR-3200-200-H VCA45--VVCA40-6-n VVCA40-4A-06-2 VVCA40-4A-06-1 Material Mounting screw (side port) Mounting screw (side port) q q Steel Steel Mounting screw (front port) Mounting screw (front port) End plate assembly (D side, side port) End plate assembly (D side, side port) w w Aluminum Aluminum End plate assembly (D side, front port)