(same side) (n 4) 2 (n 4) 2 25 + 55 135 + 55 125 + 55 BT-12 BT-12 BT-16 F5W/J59W/ F5BAL/F5F n = 2, 4, 6, 8 n = 4, 8, 12, 16 n = 4, 8, 12, 16 2 pcs.(different side, same side), 1 pc. D-F5W, J59W D-F5BAL D-F59F D-F5NTL 155 35 145 D-A3/A4/G39/K39 BS1-125 BS1-140 BS1-160 (n 4) 2 (n 2) 2 (n 4) 2 155 + 55 35 + 55 145 + 55 "n" pcs.

-140 BS1-160 CLG1 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL D-Z7/Z80 D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL 12 13 7 CL1 BS4-125 BS4-125 BS4-160 MLGC D-F59F/F5/J5 D-F5W/J59W D-F5BAL/F5NTL 5 5 5.5 [Mounting screw set made of stainless steel] The following set of mounting screws made of stainless steel (including nuts) is available.

BBA1: For D-A5/A6/F5/J5 types BBA3: For D-B5/B6/G5/K5 types The D-F5BAL/G5BAL auto switches are set on the cylinder with the stainless steel screws above when shipped. When an auto switch is shipped independently, the BBA1 or BBA3 is attached. Note 1) Refer to Best Pneumatics No. 3 for details about the BBA1 and BBA3.

Hs D-F5/J5/D-F5NTL D-F5W/J59W D-F5BAL/F59F CNS CLS 30 Auto switch CLQ A Approx. Ht Approx. Ht RLQ MLU Approx.

Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 Auto switch model Foot 50 63 80 100 CA1-L04 CA1-L05 CA1-L06 CA1-L08 CA1-L10 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NT D-F5BAL/F59F Flange CA1-F04 CA1-F05 CA1-F06 CA1-F08 CA1-F10 Single clevis CA1-C04 CA1-C05 CA1-C06 CA1-C08 CA1-C10 BT-04 BT-04 BT-06 BT-08 BT-08 Double clevis CA1-D04 CA1-D05 CA1-D06 CA1-D08 CA1-D10 When ordering foot bracket

BBA1: For use with D-A5/A6/F5/J5 D-F5BAL switch is set on the cylinder with the stainless steel screws above when shipped.

Bore size (mm) 40 50 63 80 100 Bore size (mm) 40 Auto switch model Foot 50 63 80 100 CA1-L04 CA1-L05 CA1-L06 CA1-L08 CA1-L10 D-A5/A6 D-A59W D-F5/J5 D-F5W/J59W D-F5NT D-F5BAL/F59F Flange CA1-F04 CA1-F05 CA1-F06 CA1-F08 CA1-F10 Single clevis CA1-C04 CA1-C05 CA1-C06 CA1-C08 CA1-C10 BT-04 BT-04 BT-06 BT-08 BT-08 Double clevis CA1-D04 CA1-D05 CA1-D06 CA1-D08 CA1-D10 When ordering foot bracket

Magnet: D (Built-in), Mounting: J (MT2, Head trunnion), Bore Size: 150 (1 1/2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: F5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: Built-in, Mounting: MT2, Head trunnion, Bore Size: 1 1/2", Stroke: 6", Air Cushion: Both Ends (Air Cushion), Auto Switch: F5BA--Solid State, Water Resist., 2 Wire, Lead Wire or Prewired Connector: 3m, Number: 2 pcs. (Or None in the Case of No Switch), X Option: Stainless Steel Rod

D-A5/A6 D-A59W D-B5/B6/B59W D-A3C D-G39C/K39C D-A3 D-G39/K39 D-G5/K59 D-G5W/K59W D-G5BAL D-G59F/G5NTL D-F5/J59 D-F5NTL D-F5W/J59W D-F5BAL/F5F D-A44 D-A44C Setting Position of Auto Switch (mm) Mounting Height of Auto Switch (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-A5,A6 D-A3,A3C D-B5,B6 D-G5W D-K59W D-G5BAL D-G59F D-G5 D-K59 D-G5NTL

D-A44 D-A44C Setting Position of Auto Switch (mm) Mounting Height of Auto Switch (mm) D-F5 D-J5 D-F5W D-J59W D-F5BAL D-F59F D-F5NTL D-G5 D-K59 D-G5NTL D-F5 D-J5 D-B5, B6 D-B59W D-G5 D-K59 D-G5NTL D-G5W D-K59W D-G5BAL D-G59F D-A5,A6 D-A3,A3C D-B5,B6 D-G5W D-K59W D-G5BAL D-G59F Model D-F5W D-J59W D-F5BAL D-F59F D-A3C D-G39C D-K39C D-A44C D-A3 D-G39 D-K39 D-A44 D-A5 D-A6 D-A59W D-A44,A44C D-A59W

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-F5BAL (With indicator light) RE A B D-F5BAL Auto switch model 2-wire Wiring type REC Output type 24 VDC Relay, PLC Applicable load CX Power supply voltage Current consumption CY 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current MQQ M Courtesy of Steven Engineering

Auto Switch Specifications Grommet Water (coolant) resistant type PLC: Abbreviation of Programmable Logic Controller D-F5BAL (With indicator light) CJ1 D-F5BAL Auto switch model 2-wire Wiring type CJP Output type 24 VDC Relay, PLC Applicable load CJ2 Power supply voltage Current consumption CM2 24 VDC (10 to 28 VDC) Load voltage 5 to 40 mA Load current CG1 Courtesy of Steven Engineering

Range 20D-Z7/Z80 D-Y59/Y69/Y7P/Y7PV D-Y7W/Y7WV D-Y7BAL Auto switch model Bore size (mm) Data 125 140 160 14 D-Z7/Z80 14.5 13 Hs A D-A3/A44 D-A5/A6 10 10 10 17 17 17 D-A59W Ht D-Y59/Y69 D-Y7P/Y7PV D-Y7W/Y7WV 12 13 7 6 6 7 D-Y7BAL D-F59F/F5/J5 D-F5W/J59W D-F5BAL/F5NTL B 5 5 5.5 Proper Auto Switch Mounting Position/ Auto Switch Mounting Height D-G39/K39 11 11 10 Since this is a guideline

Magnet: D (Built-in Magnet), Mounting: B (Basic), Cushion: N (Urethane Cushion), Bore Size: 63mm, Stroke: 0600 (6"), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: B (Basic), Cushion: N (Urethane Cushion), Bore Size: 63mm, Stroke: 0600 (6"), Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Cushion: A (Adjustable Air Cushion), Bore Size: 40mm, Stroke: 0600 (6"), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Cushion: A (Adjustable Air Cushion), Bore Size: 40mm, Stroke: 0600 (6"), Auto Switch: M9NA--Solid State, Water Resist., 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6

Magnet: D (Built-in), Mounting: F (MF1, Front Flange), Bore Size: 250 (2 1/2"), Stroke: 0600 (6"), Air Cushion: Both Ends (Air Cushion), Auto Switch: M9PW--Solid State, 2-color Indication, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), X Option: XC6 (Stainless Steel Rod)

Magnet: D (Built-in Magnet), Mounting: L (Axial Foot), Cushion: A (Adjustable Air Cushion), Bore Size: 40mm, Stroke: 0600 (6"), Auto Switch: M9NW--Solid State, 2-color Indication, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: L (3m), Number: 2 pcs. (Or None in the Case of No Switch), Made to Order: XC6