The maximum detectable piston speed is: Auto switch operating range (mm) Time load applied (ms) x 1000 V (mm/s) = In cases of high piston speed, the use of an auto switch (DF5NTL, F7NTL, G5NTL, M5NTL, M5PTL) with a built-in OFF delay timer ( 200 ms) makes it possible to extend the load operating time.
Description Exclusive body (-XB10) XC10 Dual stroke cylinder/Double rod type XC11 Dual stroke cylinder/Single rod type Suffix -XB10 to the end of standard model no. (page 551). Refer to How to Order for the standard model no. (page 551). Part no.
Magnet: None, Mounting: Basic, Bore Size: 2", Stroke A: 1", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 1", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 40 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500 50 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 100 1000 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 Intermediate strokes are
or less 1000 or less 1600 or less 125 -XC27 1000 or less 1000 or less 1600 or less 140 Rod side trunnion mounted on the front of the rod cover -XC30 1200 or less 1200 or less 1600 or less 160 Made of stainless steel (With hard chrome plated piston rod) -XC68 Accessory -XC86 With rod end bracket Basic Foot Rod flange Head flange Single clevis Double clevis Center trunnion For the specifications
or less 1000 or less 1600 or less 140 1000 or less 1000 or less 1600 or less 160 1200 or less 1200 or less 1600 or less -XC27: Double clev!
range B FD FE FT FX FY FZ Fd Front flange/(F) 32 40 50 63 80 100 25 31 38.5 39.5 45.5 54 125 to 1400 138 14 7 20 180 102 216 57.5 to 700 to 800 to 1000 to 1000 to 1000 to 1000 50 55 70 80 100 120 7 9 9 9 12 14 3 3 2 2 4 4 10 10 12 12 16 16 64 72 90 100 126 150 32 36 45 50 63 75 79 90 110 120 153 178 Port Cushion valve 4-FD Fd FY B Without air cushion Bore size (mm) FX FZ ZZ FT FE 32 40 147
Without air cushion Foot type/ (L) Bore size (mm) Cushion valve Port LS ZZ 32 40 50 63 80 100 134 138 156 156 184 188 168 176 198 201 240 244 LH LY 4-LD LT (mm) Foot type ZZ + Stroke LS + Stroke X Y X Y LX Bore size (mm) Stroke range X Y LD LH LS LT LX LY LZ ZZ LZ 32 40 50 63 80 100 700 800 1000 1000 1000 1000 9 11 11 14 14 16 22 24 27 27 30 32 7 9 9 12 12 14 30 33 40 45 55 65 128 3.2 3.2
Note 4) The stroke range with rod boot is up to 1000 mm. Please consult with SMC when exceeding 1000 mm strokes.
1000 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XB6 Heat resistant cylinder (150C) 100 1000 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 -XB13 Low speed cylinder (5 to 50 mm/s) 1400 Intermediate strokes are available.
Rubber bumper50 to 750 mm/s (Standard equipment) Air cushion50 to 1000 mm/s DReduced piston rod deflection -X The clearance between the bushing and the piston rod, and between the tube and the wear ring have been decreased to achieve higher accuracy.
n.05 Position reference speed 1 V/1000 min-1 Pn006 Pn007 n.06 Reserved (Do not change.)
Dual stroke cylinder/Double rod type Foot style Rod side flange style XC11 Dual stroke cylinder/Single rod type Bore size (mm) XC14 Change of trunnion bracket mounting position XC15 Change of tie-rod length 125 1600 or less 1000 or less 1000 or less XC22 Fluororubber seal 140 1600 or less 1000 or less 1000 or less XC26 Clevis pins with flat washer 160 Double clevis pin and double knuckle
Magnet: None, Mounting: Basic, Bore Size: 2", Stroke A: 10", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 10", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod
Rubber bumper50 to 750 mm/s (Standard equipment) Air cushion50 to 1000 mm/s The installation is simple because a tool can be placed directly over the cover for installation. The bearing portions of the rod cover and the clevis have been improved in wear resistance to ensure the longevity of the cylinder.
Modbus RTU protocol (Hexadecimal notation) Request data 01 08 0 1234 ED7C Response data (normal response) 01 08 0 1234 ED7C (Binary notation) Response data 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 Response data (normal response) 0001 1000 0 0 0001 0010 0011 0100 1110 1101 0111 1100 For correspondence between ASCII notation and ASCII hexadecimal notation, refer to the 8.4 ASCII
Position data Speed Dwell Auxiliary Model adaptive control 1 1000 1000 80 80 0 0 Speed control 2 2000 2000 100 100 0 0 3 4000 2000 70 60 500 1 4 500 2000 60 70 1000 1 5 2000 80 80 0 0 1000 6 2000 1000 80 80 0 0 Position 7 1000 1000 80 80 0 0 control 8 1000 1000 100 100 0 0 LEC-MR-J3BAT MR-J3BAT 1000 1000 100 100 0 0 (Note 3) CN4 255 2000 2000 80 80 0 0 Position Optional battery (for absolute
0 to 300 1% 0 Immediately Tuning -1000 to 2 Anti-Resonance Filter Time Constant 1 Compensation Pn164 0.01 ms 0 Immediately Tuning 1000 -1000 to 2 Anti-Resonance Filter Time Constant 2 Compensation Pn165 0.01 ms 0 Immediately Tuning 1000 10-11 10 List of Parameters (contd) Parameter Name Setting Units Factory When Classification Reference Size No.