Example) MY1B40G-300L-Z73-X168 X417 Note) For AS, LS and HS, the stroke adjusting unit is mounted on one side only. 8-31-132 8-31-133 115 Made to Order Individual Specifications Series MY2 Made to Order Individual Specifications: Mechanically Jointed Rodless Cylinder Series MY2 Please contact SMC for detailed dimensions, specifications, and lead times.
Bore size B Stroke Auto switch MY3 X168 Symbol Stroke adjustment unit ( MY3B and MY3M only) Port thread type Type/Bore size A B M 16 25 40 63 20 32 50 Basic short type Basic standard type Slide bearing type Example) MY3B16-300L-M9B-X168 -X416/X417 Holder Mounting Bracket q, w 4 Holder mounting brackets are used to fasten the stroke adjustment unit at an intermediate stroke position.
Bore size Stroke Auto switch Symbol MY1 H XB11 Example) MY1B40G-300L-Z73-XC67 For ordering dust seal band (NBR lining) only MY 16 B N Series/Bore size H High precision guide type 10 16 20 25 32 40 Bore size Stroke ( ) (G) indicates available by special order.
40 2.45 0.25 Operating pressure (MPa) Bore size (mm) Piston area (mm2) 63 7.14 0.56 0.2 0.3 0.4 0.5 0.6 0.7 0.8 16 0.05 0.04 0.23 0.06 16 200 160 100 120 140 80 40 60 25 0.15 0.10 0.75 0.17 MY3B 25 490 294 343 392 245 98 147 196 40 0.26 0.30 2.58 0.25 40 1256 879 1005 754 377 502 628 251 63 0.57 0.92 7.87 0.56 63 3115 2492 2180 1246 1557 1869 934 623 Calculation method Example: MY3B25-300L
Style: B (Standard Type-Air Cushion), Bore Size: 25mm, Port Thread: TN (NPT Thread), Stroke: 300mm, Stroke Adjusting Unit: L (Both Sides Shock Absorber for Low Load), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 25mm, Port Thread: TN (NPT Thread), Stroke: 300mm, Stroke Adjusting Unit: L (Both Sides Shock Absorber for Low Load), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Guide Suffix: Linear Guide, Single Axis, Bore Size: 16mm, Port Thread: Ø16 M Thread; Ø25 & 40 Rc, Stroke: 300mm, Stroke Adjusting Unit: L (Left Side Stroke Adj., w/Low Load Shock Absorber; Right Side Stroke Adj., w/Low Load Shock Absorber), Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: L (3m)
Bore Size: 25mm, Port Thread: NPT Thread, Stroke: 300mm, Stroke Adjusting Unit: Both Sides Shock Absorber for Low Load, Auto Switch: A96--Reed, DC Volt, LED, Horizontal, Lead Wire or Prewired Connector: 3m, Number: -
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 16, Stroke(mm): 300, Max. Load Mass (Horizontal Mounting)(kg): 10~19, Table Size Length L(mm): 80, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Rolling Guide] Linear guide 1 axis, Table Size Width W(mm): 83, Table Size Height H(mm): 28, Table Surface Treatment: [Anodize] Hard Anodize
Type: Rodless Cylinder, Cylinder Inner Diameter(Ø): 25, Stroke(mm): 300, Max. Load Mass (Horizontal Mounting)(kg): 10~19, Table Size Length L(mm): 95, Table Material: [Aluminum] Aluminum Alloy, Rodless Cylinder Joint Type: Mechanically Jointed, Guide: [Guideless] Prototype, Table Size Width W(mm): 61, Table Size Height H(mm): 37, Table Surface Treatment: Electroless Nickel Plating, Environment
LEL25MT-100l-l LEL25MT-200l-l LEL25MT-300l-l LEL25MT-400l-l LEL25MT-500l-l LEL25MT-600l-l LEL25MT-700l-l LEL25MT-800l-l LEL25MT-900l-l LEL25MT-1000l-l LEL25LT-100l-l LEL25LT-200l-l LEL25LT-300l-l LEL25LT-400l-l LEL25LT-500l-l LEL25LT-600l-l LEL25LT-700l-l LEL25LT-800l-l LEL25LT-900l-l LEL25LT-1000l-l With motor cover 272.5 372.5 472.5 572.5 672.5 772.5 872.5 972.5 1072.5 1172.5 292.5 392.5
FLUID OUT AIR SUP Port size Pilot air supply/ exhaust port 1/4 AIR EXH FLUID IN Liquid contact areas ADC12 SCS14 SCS14 ADC12 Material Diaphragm PTFE, NBR Automatically operated type Check valve PTFE, PFA Discharge rate 1 to 20l/min (0.03 to 0.7SCFM) 5 to 45l/min (0.2 to 1.6SCFM) Average discharge pressure 0 to 0.6MPa (0 to 87psi) Pilot air consumption Maximum 200l/min (ANR) (7SCFM) Maximum 300l
Example) MY1MW40G-2999L-Z73-XB11 Example) MY1MW40G-300L-Z73-XC67 For ordering dust seal band (NBR lining) only MY 16 B N Bore size Stroke Dust seal band NBR lining Dust seal band hexagon socket head set screw thread Black zinc chromated Nickel plated Nil W Example) MY25-16BNW-300 Refer to "Dust seal band" under the seal parts on the construction page of each series for details. 3 Holder mounting
The MY2 high precision guide cylinder is available in bore sizes 16mm, 25mm and 40mm. This series has been designed with a high precision single or double axis guide to create a compact, low profile cylinder. Maintenance has been simplified by allowing the cylinder to be detached without disturbing the guide unit and work piece.Mechanically joint rodless cylinder, High precision guide type
Specifications and how to order Specifications Model PAF5410 Main fluid suction / discharge port Rc, G, NPT 3/4, 3/4 tube piping, With nut Port size Driving air Supply / Exhaust port Rc, G, NPT 1/4 Body New PFA Diaphragm / Packing PTFE Material of wetted part Check valve New PFA, PTFE Discharge amount 5 to 45L/min Average discharge pressure 0 to 0.4MPa Pilot air consumption Max. 300L/min
Specifications and how to order Specifications Model PAF5413 Main fluid suction / discharge port Rc, G, NPT 3/4, 3/4 tube piping, With nut Port size P1 / P2 Rc, G, NPT 1/4 Body New PFA Diaphragm / Packing PTFE Material of wetted part Check valve New PFA, PTFE Discharge rate 5 to 38L/min Average discharge pressure 0 to 0.4MPa Pilot air consumption Max. 300L/min (ANR)Note 2) Dry Max. 1m (Inside
Auto drain selection for the unit style When the compressor being used is 2.2kW {300l/min (ANR)} or less, use a N.C. auto drain (Symbol: C). If a N.O. auto drain (Symbol: D) is used at 2.2kW or less, the unit may blow continuously without pressure rising inside the mist separator. However, a differential pressure type auto drain can be used even at 2.2kW or less. Warning 1.
fluid suction/ discharge port Rc 1/2, 3/4 Rc 3/8 FLUID OUT AIR SUP Port size Pilot air supply/ exhaust port Rc 1/4 AIR EXH FLUID IN Liquid contact areas ADC12 SCS14 SCS14 ADC12 Material Diaphragm PTFE, NBR Automatically operated type Check valve PTFE, PFA Discharge rate 1 to 20l/min 5 to 45l/min Average discharge pressure 0 to 0.6MPa Pilot air consumption Maximum 200l/min (ANR) Maximum 300l
0.05 0.1 0.1 0.05 S = 0.54 VDW101 10 60 50 40 30 20 10 20 VDW 1.6 S = 1.2 125 100 75 50 S = 3.2 VDW202.3 350 300 250 200 150 100 50 S = 5.8 VDW203.2 600 500 400 300 200 100 S = 2.8 VDW302 300 250 200 150 100 50 VDW303 S = 5.0 600 500 400 300 200 100 VDW304 S = 8.0 900 800 700 600 500 400 300 200 Flow rate Q l/min (ANR) Viewing the graph The sonic range pressure to generate a flow rate of 300l
0.50 41F (5C) 0.67 Inlet air pressure Inlet air pressure D F D F 145psi (1 MPa) 73psi (0.5 MPa) 1.16 0.88 Outlet air set temperature Outlet air set temperature 68F (20C) 77F (25C) Check the coefficient. 3 Correction factor = 1.36 1.07 0.50 1.16 = 0.84 Correction factor = 1.11 1 0.67 0.88 = 0.65 Calculate the corrected air flow capacity. 4 Corrected air flow capacity = 10.6 scfm (300L