Auto Switch Mounting Direct mount Rail mount Watchmakers screw driver Auto switch mounting screw (M3 x 0.5 x 10l) Set screw Auto switch spacer Auto switch D-A9 D-F9 Auto switch mounting nut When tightening the mounting screw, use a watchmakers screw driver with a handle about 5 to 6 mm in diameter. Tighten with a torque of 0.10 to 0.20 Nm.
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 Manufacture of intermediate strokes BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut Ordering Refer to standard part number and ordering on page 1.
1221-/2210-/11-/1221-/2210-/11-/1250 110 127 40 21-/2210-/11-/1283 Dual rod cylinder CXSL 1221CXS / 10-/1122Basic style / CXS15, CXSL15 10-/11221221S ZZ SS 20 10 9 2-4.3 through Z 28 counter bore depth 4.4 18 5 30 1 M6 x 1.0 x 5L (Hexagon socket head set screw) 450.2 450.2 48 56 25 58 6.3 5 2-M4 x 0.7 thread depth 6 1 M4 x 0.7 x 14.5L and M4 x 0.7 (Hexagon bolt) (Hexagon nut) 9 M5 x 0.8 x 10L
Switch mounting screws (M3 x 0.5 x 10l) Switch spacer 32, 40 50, 63 RS H A Manufacture of Intermediate Stroke BQ-2 Method Spacers installed in standard stroke body. Switch mounting nut RZQ Ordering Refer to standard part number and ordering on page 10-10-2.
. -19No.PF-OMG0008-F Initialize mode Default settings PF2A3 series Item Default settings Page PF2A30 series [10L] 1 to 10 L/min type (PF2A510) Selection of the connected sensor Page 21 PF2A31 series [11L] 10 to 100 L/min type (PF2A511) Selection of display mode [d_1] Display instantaneous flow Page 22 Unit selection function [U_1] L/min Selection of output mode (OUT1) [o10] Instantaneous
. -20No.PF-OMH0003-F Initialize mode Default settings PF2A20 series Item Default settings Page Selection of the connected sensor [10L] 1 to 10 L/min type (PF2A510) Page 22 Selection of display mode [d_1] Display instantaneous flow Page 23 Unit selection function [U_1] L/min Selection of output mode [o10] Instantaneous output mode Selection of switch operation [1_n] Reverse output Page 24
Since discharge rate 45% of fresh water is equal to 4.5L/min of the fluid, with the following calculation; 4.5L/min 0.45 = 10L/min it is found discharge rate 10L/min is necessary for fresh water. 3. Then, refer to flow characteristic graph and calculated air pilot pressure.
(The capacity of the container should be approx. 10L) Circulating fluid return port Tank lid Circulating fluid outlet Drain port Clip Drain plug Container Normal Liquid discharge Fig. 8-4 Drain the circulating fluid from the product 2. Remove the tank lid. 3. Remove the drain plug on the drain port on the piping to discharge the fluid. An O ring is used for the drain plug.
Purge flow rate should be 5 to 10L/min. The product cannot be sealed completely. Therefore all purge fluid may not come out from purge OUT port. Purge should be applied for prevention of condensation and internal build-up of corrosive gas.
with the M4 tap of Rod cover holding hexagon socket head cap screw Collar holding hexagon set screw Bore size (mm) Recommended tightening torque (Nm) 0.59 to 1.06 0.33 to 0.61 0.59 to 1.06 0.33 to 0.61 2.84 to 5.10 0.59 to 1.06 2.84 to 5.10 1.37 to 2.45 2.84 to 5.10 0.20 to 0.39 0.20 to 0.39 0.20 to 0.39 M3 x 0.5 x L M2.5 x 0.45 x 6L M3 x 0.5 x L M2.5 x 0.45 x 6L M5 x 0.8 x L M3 x 0.5 x 10L
Auto switch mounting nut Auto switch fixing screw (M2.5 x 0.45 x 10L) Tightening torque of auto switch mounting screw (Nm) Auto switch model Tightening torque D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) Auto switch mounting screw (M3 x 0.5 x 8L) 0.05 to 0.15 Auto switch 0.10 to 0.20 Auto switch spacer Auto switch mounting nut Note) The auto switch mounting bracket and auto switch are enclosed with
t(s) Charging time for 10l t(s) Pressure increase ratio (P2/P1) Pressure increase ratio (P2/P1) These graphs illustrate the time required to inrease pressure in a closed tank e.g.
MHS MHC2 MHT2 MHY2 MHW2 MRHQ Auto switch 2.6-2 Series MHC2 Double Acting 10, 16, 20, 25 MHC2-10l Note) When signal acting type is used, one side port is bleed port and adjusting needle for finger speed is not attached. When auto switch is used, through hole mounting type is not available.
Applicable auto switch Reed switch Solid state switch I Auto switch mounting screw (M3 X 0.5 X 8l) ISquare nut IAuto switch mounting screw (M3 X 0.5 X 10l) IAuto switch spacer IAuto switch mounting nut ISwitch mounting bracket IAuto switch mounting nut ICross-recessed panhead small screw (M3 X 0.5 X 16l) IHexagon socket head cap bolt (M3 X 0.5 X 14l) 20/25 D-A7, A8 D-A73C, A80C D-A7lH, A80H
t(s) Charging time for 10l t(s) Pressure increase ratio (P2/P1) Pressure increase ratio (P2/P1) These graphs illustrate the time required to inrease pressure in a closed tank e.g.
One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector Valve Unit Series ZYY/ZYX Ejector Valve Specifications Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted ZY3-07S ZY3-07L ZY3-10S ZY3-10L
One-touch fitting Manifold base (4 stations) ZZYY3-45-04D-C6-J1U With ejector Number of ejectors 1 to 10 Example) ZYY-J3U ZYY35LZ-10S1-E15C ZYY35LZ-10S 2 SET 1 SET 1 SET U side Stations3 2 1 D side 13-8-6 7 Ejector Valve Unit Series ZYY/ZYX Ejector Valve Specifications Series SY3000/SX3000 in manifold/split base combinations DIN rail mount type can be mounted ZY3-07S ZY3-07L ZY3-10S ZY3-10L
BQ4-012 BQ5-032 Auto switch fixing screw (M2.5 x 10L) Auto switch mounting screw (M3 x 8L) Auto switch spacer Auto switch mounting nut Weight: 3.5 g Auto switch mounting bracket fitting parts lineup/weight Auto switch mounting screw (M2.5 x 8L) Auto switch mounting nut Weight: 1.5 g A/B/C side except port side (12) Surfaces with auto switch mounting slot Auto switch mounting rail
(Including nut, screw) Cylinder series Applicable bore size (mm) 40 BMY2-025 BMY1-025 ML1 25 BMY2-025 BMY1-025 32 BMY2-025 BMY1-025 Tightening torque (Nm) 0.8 to 1.4 M2.5 x 12l M2.5 x 10l D1371