Parallel output Stop points Compatible encoder Serial communication Memory LED indicator 7-segment LED display Note 3) Lock control Cable length [m] Cooling system Operating temperature range Operating humidity range [%RH] Storage temperature range Storage humidity range [%RH] Insulation resistance [M] Weight I/O cable: 5 or less Actuator cable: 20 or less Natural air cooling 32 to 104F (0 to 40C
Unit AC20C to 40C Dimensions AC20C A Pressure gauge port size G Q F E T L P B C H IN OUT U H L J Pressure gauge (accessory) K M Square embedded type pressure gauge (accessory) Port size N Min. clearance for maintenance Drain Drain D Air filter Mist separator Regulator AC25C, 30C, 40C A Q G F E T Pressure gauge port size L P H B C OUT IN U H L Pressure gauge (accessory) K M Square embedded
Min. bending radius (mm) 75 60 48 36 24 25 13 100 15 20 30 60 75 Caution Operating temperature 20 to +60C (Water: 0 to 40C) (No freezing) 1. Applicable for general industrial water. Please consult with SMC if using other kinds of fluid. Surge pressure must be under the max. operating pressure.
Operating temperature 32 to 104F (0 to 40C) Material Conductive nylon + Flame resistant nylon (Equivalent to UL-94 Standards V-0) Surface resistance 104 to 107 Hardness Shore D 48 Note 1) Refer to the burst pressure characteristics and operating pressure curve for other temperatures. Avoid abnormal temperature rises due to adiabatic compression.
Brake Without brake With brake Nil B Home position switch None Yes (cable length 0.3m) Nil S Specifications Motor AC servomotor (30w) Ball screw 8mm Lead screw Positioning repeatability Lead Maximum speed 0.03mm 2mm 40mm/s 3 (2)kg 2kg 5mm 100mm/s 3 (2)kg 2kg Horizontal Vertical Work load Note 1) Guide type Operating temperature range Direct acting guide 5 to 40C (with no condensation) Photo
Burst prssure Min. bending radius (mm) 10 15 20 27 35 10 15 23 27 35 20 to +60C (Water: 0 to 40C) (No freezing) Polyurethane Operating temperature Material Precautions How to Order Be sure to read before handling.
Nylon, Soft nylon, Polyurethane 3.2, 4, 6 Specifications Fluid Air/Water Note) 1.0 MPa 100 kPa 3.0 MPa 5 to 60C, Water: 0 to 40C (No freezing) JIS B 0203 (Taper thread for piping) JIS B 0209, Class 2 (Metric coarse thread) Mounting section Maximum operating pressure Operating vacuum pressure Proof pressure Ambient and fluid temperature Thread Nut section With thread seal JIS B 0211 Class
(mm) 8 2 2.5 4 5 6.5 M Black (B) H/DL L/LL Air Fluid KC 20C 0.9 Max. operating pressure (MPa) 40C 0.7 KK Recommended fittings Antistatic one-touch fittings: KA series Miniature fittings: M and MS series Note) Minimum bending radius (mm) 10 15 20 27 35 10 KK130 0 to 40C Operating temperature Max.
Allowable voltage range [V] Rated voltage [A] Single phase 200 to 230 VAC (50/60 Hz) Single phase 170 to 253 VAC Single phase 100 to 120 VAC (50/60 Hz) Single phase 85 to 132 VAC 1.5 24 VDC 21.6 to 26.4 VDC 0.5 6 inputs 4 outputs 1 M (when differential receiver), 200 k (when open collector) 0 to 65535 (Pulse command unit) 3 rotations Parameter setting USB communication 32 to 104F (0 to 40C
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.
HAA HAW IDFAE Selection Example AT 1 Correction factor Note) Data symbol 40C Condition Read the correction factor.
value of pushing force [%] Duty ratio [%] Continuous pushing time [minute] 40C or less 95 or less 100 10 20 30 40 50 60 70 80 90 0 25ASet value of pushing force [%] LEC
Nylon, Soft nylon, Polyurethane , , , , 5 32 1 4 5 16 3 8 1 2 T VMG KM11 Specifications Fluid Air Water Note) Model KM11 KM12 KM12 1.0 MPa Maximum operating pressure Proof pressure Ambient and fluid temperature 3.0 MPa 5 to 60C (Water: 0 to 40C) (No freezing) ANSI/ASMEB1.20. 1-1983 (NPT thread) Thread Note) Applicable for general industrial water.
OUT Standard specification Option Note) Water (Standard, up to 40C) Air (Standard, Dry) Turbine oil Vacuum (up to 1.3 x102 Pa) Carbon dioxide (CO2), Nitrogen gas (N2) Vacuum (up to 1.3 x101 Pa) (V, M) Non-leak (106 Pa m3/s or less) (V, M) IN N.O.
Products Color Series Body Release button Series KQ2 White Light gray Series KQ Black Blue Specifications Fluid Air/Water (2) Operating pressure range (3) 100 kPa to 1 MPa 3 MPa Proof pressure Ambient and fluid temperature 5 to 60C, Water: 0 to 40C (No freezing) Note 2) The surge pressure must be under the maximum operating pressure.
Operating Pressure Air 145psi (1.0MPa) Size At 75F (24C) At 200F (93C) 3/8 1/4 1/2 5/32 5/8 3/4 1400psi 1200psi 950psi 1200psi 900psi 800psi Proof Pressure 450psi (3.1MPa) Recommended Fluid and Ambient Temperature* -40F to 140F (-40C to 60C) 7 Ncm/min. or less Leak Rate at -40F (-40C) Thread Portion Nut ANSI/ASME B1.20.1, 1983, R1992 Thread JIS B 0208 (Unified fine thread), ISO 263 Thread
0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.
Max. ambient temperature 40C P. 12 IDF1E to 11E IDU3E to 6E Bypass piping set Max. operating pressure 1.0 MPa Max. operating temperature 60C Easy bypass piping (connect this set to the air dryer), allowing substantial reduction in the installation time.
-XB7 Cold resistant (40C) Applicable Model Standard, Double acting, Single rod C(D)U XB7 Enter the applicable model number.