-M9NL u Seal material and its changed part Seal material Seal material Compound No.

Lead wire length symbols: 0.5 mNil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Solid state switches marked "" are produced upon receipt of order.

Specification: 11- (Clean Series, Vacuum Type), Bore Size: 4.5 mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal

Specification: 11- (Clean Series, Vacuum Type), Bore Size: 4.5 mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: C (Metal Stopper Both Ends), Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: M (1m)

Specification: Clean Series, Vacuum Type, Bore Size: 4.5 mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: -, Number: -

Specification: Clean Series, Vacuum Type, Bore Size: 4.5 mm, Symmetric Type: Standard, Stroke: 10mm, Adjuster: Metal Stopper Both Ends, Function: w/o Axial Piping, Switch Rail: w/Magnet & Switch Rail, Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Lead Wire or Prewired Connector: 1m, Number: -

1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.

Lead wire length symbols:0.5 m Nil (Example) M9N 3 m L (Example) M9NL 5 m Z (Example) M9NZ Refer to page 12-13-25 for solid state switch with pre-wire connector. 12-5-4 5 2 Finger Rotary Actuated Air Gripper Series MHR2/MDHR2 30 Model/Specifications Nominal size 10 15 20 Action Double acting Gripping force (N) (1) External grip 12 24 33 58 (Effective value) at 0.5 MPa Internal grip 12 34

Lead wire length symbols: 0.5 m Nil (Example) M9N 1 m M (Example) M9NM 3 m L (Example) M9NL 5 m Z (Example) M9NZ MA D491 Series MHR2/MDHR2 Model/Specifications Nominal size 20 10 15 30 Double acting Action Gripping force (N) (1) External grip 33 12 58 24 (Effective value) at 0.5 MPa Internal grip 34 12 59 25 Finger closing width (mm) Finger opening width (mm) 16 10 19 14 Opening/ Closing

L M9NL 5 m . Z M9NZ Refer to page 731 for further information on auto switches. Order with an auto switch part number when ordering a single auto switch unit. Auto switches marked with a "" are made upon receipt of order.

Example) -M9NL Symbol Nil A B C Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

, 12 V A93 A90 M9N M9P M9B F9NW F9PW F9BW A93V A90V M9NV M9PV M9BV F9NWV F9PWV F9BWV 2-wire Relay, PLC IC circuit 100 V or less No 3-wire (NPN) IC circuit 5 V, 12 V 3-wire (PNP) 2-wire 12 V Grommet Relay, PLC Yes 24V 3-wire (NPN) 3-wire (PNP) IC circuit 5 V, 12 V Diagnostic indication (2-color indication) 2-wire 12 V Lead wire length symbols: 0.5 mNil (Example) M9N 3 mL (Example) M9NL

1 series 10C 20C 30C Standard model (Normal operation) Set dew point Accumulated running hours display Helps maintenance control of the dryer. Gives notice of the maintenance timing etc. 1. Energy saving operation (ECO LED is ON green): Dew point can be set manually between 10 to 30C. 2. Normal operation (ECO LED is OFF): Dew point is fixed to 10C. Description No.

) Circulating fluid system Cooling water system Electrical system 2.0 (at 10C) 1.0 (at 20C) 2.0 (at 20C) 4.0 (at 20C) 8.0 (at 20C) 2.0 (at 20C) 8.0 (at 20C) 4.0 (at 10C) 8.0 (at 10C) 2.8 (at 10C) 3.2 (at 10C) 2.3 (at 20C) 2.6 (at 20C) 2.8 (at 20C) 3.0 (at 20C) 2.3 (at 20C) 3.3 (at 20C) 3.6 (at 10C) 5.9 (at 10C) Cooling capacity Note 3) (kW) Heating capacity Note 3) (kW) Temp. stability Note

D-A79W cannot be mounted on bore size 10 cylinder with air cushion. 1.3-2 Standard: Double Acting Single Rod Series CJ2 Specifications Double acting/Single rod Action Air Fluid 1.05MPa Proof pressure 10.7MPa Max. operating pressure 0.12MPa 6 Min. operating pressure 0.06MPa 10, 16 Without auto switch: 10C to 70C, With auto switch: 10C to 60C Ambient and fluid temperature CJ1 Rubber bumper/

CJ1 Maximum operating pressure 0.7 MPa Minimum operating pressure 0.06 MPa CJP Ambient and fluid temperature Without auto switch: 10C to 70C (No freezing) With auto switch: 10C to 60C CJ2 CJ2 Cushion Rubber bumper Lubrication Not required (Non-lube) JCM Stroke length tolerance +1.0 0 Rod non-rotating accuracy 1.5 1 CM2 Double acting, Single rod, Rubber bumper Symbol Piston speed 50 to 750

Without auto switch: 10C to 70C (No freezing) CQS Ambient and fluid temperature With auto switch: 10C to 60C (No freezing) Rubber bumper None CQ2 Rod end thread Female thread Allowable Kinetic Energy Tolerance of rod end thread JIS class 2 MU +1.0 0 Tolerance of stroke length Refer to p.2.3-4 for allowable kinetic energy.

temperature: 95F (35C) 600 1200 Ambient temperature: 86F (30C) 500 1000 Ambient temperature: 59F (15C) 400 800 Ambient temperature: 59F (15C) 300 600 200 400 100 200 0 0 0 0 10C 20 30 40 50 60 70 40F 60 80 90 110 130 150 10C 20 30 40 50 60 70 40F 60 80 90 110 130 150 Circulating fluid temperature Circulating fluid temperature Pump Capacity (Thermo-con Outlet) The pressure on the y-axis shows