Ambient and fluid temperature Response time (at 0.5 MPa) (1) 10 ms or less (Standard), 15 ms or less (Low power consumption type) Non-locking push type Not required (Use turbine oil Class 1 ISO VG32, if lubricated.)
Delay Time 1.5 ms1 or less 1 Select from 1.5 ms or less, 20 ms, 100 ms, 500 ms, 1000 ms, 2000 ms, or 5000 ms. Convenient Functions p. 17, 26 Functions Copy function Auto-shift function Security code Power saving mode Resolution switch function MPa/kPa switch function 20 20A 20B 20B-L 20C Copy function The settings of the master sensor can be copied to the slave sensors.
4000 [rad/s] PB32 VICB 50 [ms] PB26 CDP 0003 () PB27 CDL 50 [pulse] PB28 CDT 100 [ms] 7 19 7.
Problem 1 PWR PWR is OFF OFF Problem 2 Red Flashing MS MS LED does not turn on green. Problem 3 Red ON OFF Red Flashing W-SS W-SS LED flashes red or orange or is off Problem 4 Orange Flashing OFF Green Flashing Red Flashing Red ON W-NS W-NS LED does not turn on green. Problem 5 Red Green Alternate Flashing OFF Red Flashing W-MS W-MS LED does not turn on green.
LAT3LAT3MLAT3F600 350 700 Min. travel time [ms] Min. travel time [ms] Min. travel time [ms] Load weight1000g Load weight1000g Load weight1000g 300 600 [ms] 500 [ms] [ms] 700g 700g 700g 250 500 400 500g 500g 500g 200 400 300 150 300 200 100 200 300g 300g 300g 100 100g 100g 50 100 100g 0g 0g 0g 0 0 0 0 10 20 30 40 50 0 5 10 15 20 25 30 0 10 20 30 40 50 Total travel distance [mm] Total travel
(mm) 4 Translucent (N) 250 m reel 500 m reel Specifications Fluid Air, Water Note 1), Inert gas Applicable fittings Note 2) One-touch fittings, Insert fittings Fluoropolymer fittings: Series LQ Miniature fittings: Series M, MS (Hose nipple type) Operating Temperature: Max. 200C It varies depending on the operating pressure.
Enable 1 Disable Enable 100 msec 2 Disable 0.1 ms 1.0 ms 3 1.0 ms 10 ms 20 ms 1.0 ms 15 ms 4 15 ms 100 ms 200 ms Enable 5 1 Disable Auto 6 Manual Enable 7 Disable Clear OFF 8 Hold 2 ForceON ON Clear OFF 9 Hold 2 3 ForceON ON -47No.EX-OMS0026CN No.
(40 ms) [SOL.a] () [SOL.a] (+) The values in ( ) are for the high pressure and quick response types.
/deceleration time constant (ms).
/deceleration time constant (ms).
And it can be used in the vacuum applications. 2 position single/3 position 0.15 to 0.9 MPa Operating pressure range 2 position double VF 0.1 to 0.9 MPa Max. 50C Ambient and fluid temperature 2 position double VFR 45 ms or less Note) 45 ms or less Note) Response time 3 position 60 ms or less Note) 70 ms or less Note) 2 position double VP4 Max. operating frequency 5 Hz 5 Hz Courtesy of Steven
PB27 CDL 10 PB28 CDT 1 ms PB29 GD2B 7.0 PB30 PG2B 37 rad/s PB31 VG2B 823 rad/s PB32 VICB 33.7 ms PB33 VRF1B 100.0 Hz PB34 VRF2B 100.0 Hz 5 12 5 No.
(Coil temperature: 20C, at rated voltage) SY3000 SY7000 With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) With light/surge voltage suppressor Response time (ms) (at the pressure of 0.5 MPa) Type of actuation Without light/surge voltage suppressor 12 or less Type of actuation Without light/surge voltage suppressor 31 or less Type R, U Type S, Z 12 or less
1208 12 8 BU C B Blue (Translucent) Clear (Material color) M-3AU-2, M-3AU-4 M-5AU-2, M-5AU-4 M-5AU-6, M-5H-4 M-5H-6 MS-5AU-4, MS-5AU-6 MS-5H-4, MS-5H-6 Black (Translucent) 500
or more 10 ms or less when auto shift inputs.
, 5 ms, 15 ms 3 ms Static Power source for cross-circuit detection Disable, UT1, UT2 UT1 (Input N) UT2 (Input N+4) Static Discrepancy time Disable, 10 ms, 50 ms, 100 ms, 1 s, 5 s 10 ms Static Start inhibit after discrepancy Disable, Enable Enable Static : Filter time Power source for cross-circuit detectionSensor evaluation Discrepancy time Start inhibit after discrepancySensor evaluation1oo2
MS Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com T Union elbow Male run tee Bulkhead connector VMG Use to branch line in the same direction from female thread and 90 direction.
Auto Switch Specifications Grommet With built-in OFF-delay timer (200 ms) PLC: Abbreviation of Programmable Logic Controller D-F7NTL (With indicator light) RE A B D-F7NTL Auto switch model Wiring type 3-wire REC Output type NPN Output operation Off-delay CX Operating time 1 ms or less Off-delay time 200 50 ms CY Applicable load IC circuit, Relay, PLC MQQ M Power supply voltage 5, 12, 24