Weight (g) D-F8N D-F8P D-F8B Auto switch model 0.5 m (Nil) 7 3 m (L) Lead wire length 32 5 m (Z) 52 Dimensions (mm) D-F8N/D-F8P/D-F8B M2.5 x 4 L Slotted set screw 4.3 Indicator light 2 10 2.8 2.7 4.6 3.1 10.9 3 4 Most sensitive position 8 1576 Normally Closed Solid State Auto Switch Direct Mounting Style D-F9G/D-F9H RoHS Refer to SMC website for the details of the products conforming to the
Refer to Best Pneumatics Vol. 6/7/8/9/10 for the details.
, D-F8B Auto Switch Specifications Grommet D-F8P D-F8N D-F8B Auto switch part no.
Refer to Best Pneumatics Vol. 6/7/8/9/10 for the details.
Refer to Best Pneumatics Vol 6/7/8/9/10 for the details.
, D-F8B Auto Switch Specifications Grommet D-F8P D-F8N D-F8B Auto switch part no.
8 10 10 12 12 6 5 8 7 10 9 12 12 M2 x 0.4 M2 x 0.4 M3 x 0.5 M3 x 0.5 M4 x 0.7 M4 x 0.7 M5 x 0.8 M5 x 0.8 3.6 3.6 6 6 8 8 10 10 3 2 4 2.5 5 3.3 6.5 3.5 5.2 5.2 8.3 8.3 10.5 10.5 13.1 13.1 12 9 16 12 20.8 15.5 25 19 MHZ2-10-X51 MHZ2-16-X51 MHZ2-20-X51 MHZ2-25-X51 Dimensions other than the above are identical to the standard type; refer to pages 12-2-33 to 12-2-36. 12-2-58 58 12-2-59 59 Parallel
8 10 10 12 12 6 5 8 7 10 9 12 12 M2 x 0.4 M2 x 0.4 M3 x 0.5 M3 x 0.5 M4 x 0.7 M4 x 0.7 M5 x 0.8 M5 x 0.8 5.2 5.2 8.3 8.3 10.5 10.5 13.1 13.1 12 9 16 12 20.8 15.5 25 19 3.6 3.6 6 6 8 8 10 10 3 2 4 2.5 5 3.3 6.5 3.5 MHZ2-10-X51 MHZ2-16-X51 MHZ2-20-X51 MHZ2-25-X51 Dimensions other than the above are identical to the standard type; refer to pages 12-2-33 to 12-2-36. 12-2-58 58 Courtesy of Steven
18 22 8 12 18 22 8 12 18 22 60 135 270 470 70 145 290 515 70 140 290 515 17 45 66 104 Double acting Single acting type, Normally open Normally closed Normally open Single acting Single acting type, Normally closed 13 38 57 85 MHZ MHF Note 1) Values based on pressure of 0.5 MPa, gripping point L = 20 mm, at center of stroke.
DC (+) Brown 0.5 7 7 7 Lead wire length (m) 3 32 32 32 Switch main circuit Switch main circuit Switch main circuit OUT Black 5 52 52 52 DC () Blue Dimensions D-F8N, D-F8P, D-F8B D-F8P Mounting screw M2.5 x 4l Slotted set screw DC (+) Brown 4.3 Indicator light 2 2.7 OUT Black 10 2.8 4.6 DC () Blue 3.1 10.9 3 D-F8B OUT (+) Brown 4 Most sensitive position 8 OUT () Blue 8
Action D S Rod end threads Double acting Single acting (spring extended) Rod end female threads (4 without threads) Rod end male threads Nil M Table 2 Auto switch specifications Table 1 Standard strokes Action Bore size (mm) 4 6 8, 10 4 6 8, 10 Standard stroke (mm) 4, 6, 8, 10 4, 6, 8, 10, 15 4, 6, 8, 10, 15, 20 4, 6 4, 6, 8 4, 6, 8, 10 Load voltage Lead wire length (m) Indicator light Wiring
Bore Size: 10mm, Stroke: 5mm, Auto Switch: F8P--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch)
Bore Size: 10mm, Stroke: 20mm, Auto Switch: F8P--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch)
Bore Size: 10mm, Stroke: 5mm, Auto Switch: F8P--Solid State, Gen. Purpose, 3 Wire PNP, Vertical, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch)
5 15.31 9.18 IN 30.6 21.44 Data 39.26 23.56 OUT 78.5 54.97 10 6 25.13 15.07 IN 50.3 35.18 Spring Reaction Force/Single Acting Standard Stroke Bore size (mm) 4 6 8, 10 4 6 8, 10 Standard stroke (mm) 4, 6, 8, 10 4, 6, 8, 10, 15 4, 6, 8, 10, 15, 20 4, 6 4, 6, 8 4, 6, 8, 10 Action IN Spring in pre-loaded condition Spring in loaded condition OUT Double acting Single acting, Spring return When
5 15.31 9.18 IN 30.6 21.44 Data 39.26 23.56 OUT 78.5 54.97 10 6 25.13 15.07 IN 50.3 35.18 Spring Reaction Force/Single Acting Standard Stroke Bore size (mm) 4 6 8, 10 4 6 8, 10 Standard stroke (mm) 4, 6, 8, 10 4, 6, 8, 10, 15 4, 6, 8, 10, 15, 20 4, 6 4, 6, 8 4, 6, 8, 10 Action IN Spring in pre-loaded condition Spring in loaded condition OUT Double acting Single acting, Spring return When
Avoid sources of surge generation and crossed lines. 8. Avoid accumulation of iron debris or close contact with magnetic substances.
Avoid sources of surge generation and crossed lines. 8. Avoid accumulation of iron debris or close contact with magnetic substances.