(Except 50) MY1MW16/20/50/63 MY1CW16/20/50/63 L L L L L L R R R R R R R L L R R R L L L R Slide table operating direction MY1MW25/32/40 MY1CW25/32/40 L L This port is not available for use. (Except 32, 40) L L L L L L L L R R R R R R R R L L R R L L L R Slide table operating direction 8-12-3 4 Series MY1W Specific Product Precautions 2 Be sure to read before handling.
LEFS16(L/R)/Ball Screw Drive Horizontal Vertical 16 6 Lead 5: LEFS16(L/R)EB 14 12 Lead 5: LEFS16(L/R)EB Work load: W [kg] Work load: W [kg] 4 10 Lead 10: LEFS16(L/R)EA 8 Lead 10: LEFS16(L/R)EA 6 2 4 2 0 0 0 100 200 300 400 500 600 0 100 200 300 400 500 800 600 700 Speed: V [mm/s] Speed: V [mm/s] LEFS25(L/R)/Ball Screw Drive Horizontal Vertical 20 30 Lead 6: LEFS25(L/R)EB Lead 6: LEFS25(L/
y y e u e r t u r i u Drain Drain Drain Component Parts No.
3(R) y t r y t r y t r w q e w q e w q e 3(R) 3(R) 3(R) 1(P) 1(P) 1(P) X X 6 VP500/700-X536 Dimensions Residual Pressure Release Valve (-X536) VP542(R)-5 D YZ1-03 -X536 VP542(R)-5 D YZ1-03 -M -X536 3/8" [2(A) port] Port size: 1/8" (Without check valve) Applicable tube O.D.: 6, 1/4" (With check valve) (External pilot port) 31 2 x 4.2 (For mounting) Safety limit switch Made by OMRON 3.5 7
t H R q Accuracy e Motor mounting position r Motor type t Lead [mm] y Stroke [mm] Nil Basic type H High precision type 50 50 to to 1200 1200 Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 Nil In-line R Right side parallel L Left side parallel Symbol Type NZ Mounting type Z NY Mounting type Y NX Mounting type X NW Mounting type W NV Mounting type V NU Mounting type U NT Mounting
absorption unit LC7R-K1A Note) Select 6mA or less for resistor R after confirming the input capacity of the control equipment.
VG External Pilot Port VP Series Port size SYJ500/700 M5 x 0.8 S070 JIS Symbol VQ Body ported N.C. N.O. VKF (A) 2 (A) 2 X X VQZ 1 (P) 3 (R) 1 (P) 3 (R) VZ VS VFN 4-4-55 56 Series SYJ300/500/700 Specific Product Precautions 1 Be sure to read before handling.
How to Order w e r q t y u i o !
125, 150, 50 MY 350, 400, 450, 500, 600, 700, 800, 900, 1000 200, 250, 300 63 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100 MGGL Ball bushing bearing CY 80 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200 100 350, 400, 450, 500, 600, 700, 800, 900, 1000, 1100, 1200, 1300 MG Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650
A B C D Maximum Speeds for Each Transfer Load Unit (mm/s) Transfer load (kg) 10 20 30 40 50 60 1000 700 500 1000 700 500 Model Note LJ1H3031PD-200 to 1000LJ1H3031PD-1200LJ1H3031PD-1500LJ1H3032PD-200 to 1000LJ1H3032PD-1200LJ1H3032PD-15001000 700 500 900 700 500 1000 700 500 800 700 500 1000 700 500 700 700 500 900 700 500 650 650 500 800 700 500 600 600 500 Power supply: 100/110(V)AC 10% Compatible
Body Brass Body Hydrolic Oil Non-Flammable NR NR NR NR Standard R R R R Hydrochloric Acid NR NR NR NR Hydrogen R R R R # Inert Gases R R R R JP4 JET Fuel V V V V JP5 JET Fuel V V V V Kerosene R R R R Ketones PP NR PP NR Lacquer PP PP PP PP Linseed Oil R R R R Lubrication R R R R Mercury R*** NR R*** NR Natural Gas R R R R Nitric Acid PP NR PP NR Nitrogen R R R R Oxalic Acid NR NR NR NR Oxygen
www.stevenengineering.com A C T U AT O R S P R O D U C T S E L E C T O R PA G E 1.1 VA LV E S P R O D U C T S E L E C T O R PA G E 2.1 F L O W C O N T R O L E Q U I P M E N T P R O D U C T S E L E C T O R PA G E 3.1 F I T T I N G S A N D T U B I N G P R O D U C T S E L E C T O R PA G E 4.1 A I R P R E PA R AT I O N P R O D U C T S E L E C T O R PA G E 5.1 VA C U U M P R O D U C T S E L E
, 700, 800 Heat resistant cylinder (150C) -XB6 Intermediate strokes are available.
Model Number Description R-800-XX-W/K Precision regulator with adjusting knob R-800-XX-W/S Precision regulator with 1/4" adjusting shaft R-800-XX-W/OS Precision regulator with slotted adjusting shaft R-801-XX Factory pre-set regulator R-810-XX-W/K Non-bleed, non-relieving with adjusting knob R-810-XX-W/S Non-bleed, non-relieving with 1/4" adjusting shaft R-810-XX-W/OS Non-bleed, non-relieving
1 3 O P T I O N S E R I E S N C Y 2 Bore Size (mm) 6 ~ 40 Fluid Air Piston Speed 7 ~ 50mm/s H O W T O O R D E R S E R I E S NCY2 B A S I C T Y P E A I R H Y D R O R O D L E S S C Y L I N D E R O P T I O N H O W T O O R D E R S E R I E S NCY2 S L I D E R T Y P E A I R H Y D R O R O D L E S S C Y L I N D E R O P T I O N X116 NC(D)Y2 S X116 NCY2 B S W I T C H B O R E S I Z E S T R O K E ( I
/N.O. 2(A) 3/8 1/2 15.3 Air operated valve (P)1 3(R) VPA300 N.C. 2(A) 1/8 1/4 3.8 (P)1 3(R) N.O. 2(A) VPA500 (P)1 3(R) 1/4 3/8 P. 1564 8.8 For vacuum N.C. 2(A) VPA700 (P)1 3(R) 3/8 1/2 N.O. 15.0 2(A) (P)1 3(R) 1556 VPA300/500/700 Series Model Selection by Operating Conditions w Air Operated Valve: Manifold Series Manifold base model Applicable stations Note) EXH port type SYA VV3PA3-41 SYJA
8.4 NO X X PE NC 30.5 30.5 116.1 98.6 91.6 91.6 2(A) 3(R) 66.8 57.6 1(P) 43.8 43.8 34 34 71 (P port) Rc 1/2, 3/4, 1 (R port) Rc 1/2, 3/4, 1 (A port) Rc 1/2, 3/4, 1 5-5-12 1 3 Port Air Operated Valve Series VPA300/500/700 How to Order SA A 01 2 4 3 VPA VA Option VP Air operated valve None With bracket (Only VPA342, VPA542 and VPA742) Nil F SA Body size VPA542 Passage 3 5 7 1/4 standard 3/8
560 700 470 470 620 470 620 560 700 560 700 560 700 4.5 0.61 15 1 4 (8A) 1.0 6 1.1 26 6 1.1 26 8 1.6 38 3 0.33 7.9 0.5 500 10 4.5 0.61 15 1.9 46 3 8 (10) 660 500 660 3 7.9 0.33 6 1.1 26 4.5 0.61 15 1.0 Note) Weight of grommet type.