SMC Corporation of America
Elite Part Number Search
Search Results "LVM09R4-6A-Q"

w e q w VQC1100 VQC1101 2(B) (A)4 2(B) (A)4 r r (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) e q w e w q VQC1201 VQC1200 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) r r e q w e q w VQC1300 VQC1400 VQC1301 VQC1401 2(B) (A)4 2(B) (A)4 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) (R1)5 1 (P) 3(R2) VQC1500 VQC1501 r r 2(B) (A)4 2(B) (A)4 (R1)5 1 (P) 3(R2) (R1)5

L n Dimensions 9 288 477 8 263 452 L1 L2 10 313 502 7 238 427 11 338 527 6 213 402 12 363 552 5 188 377 13 388 577 4 163 352 14 413 602 3 138 327 15 438 627 2 113 302 16 463 652 2-5-29 Series VQ4000 Construction Plug-in Unit e q w e q w Metal seal type Rubber seal type (A) 4 (B) 2 42 (A)(B) VQ4101 VQ4100 1 (P) 5 (R1) (R2) 3 1 (P) 5 (R1) (R2) 3 e q w e q w (B) (A) 42 4 (B) 2 (A) VQ4200 VQ4201

-20(-Q) 10-SS5YJ5-20P(-Q) Applicable manifold base 10-SS5YJ5-40(-Q) 10-SS5YJ5-41(-Q) 10-SS5YJ5-42(-Q) 10-SS5YJ5-43(-Q) 10-SS5YJ5-41P(-Q) 10-SS5YJ5-43P(-Q) Applicable manifold base Type 10-SS5YJ5-41(-Q) Type 10-SS5YJ5-42(-Q) Type 10-SS5YJ5-43(-Q) Type 10-SS5YJ5-41P(-Q) Type 10-SS5YJ5-43P(-Q) Caution Mounting screw tightening torque M2.5: 0.45 Nm Use caution to the assembly orientation

www.stevenengineering.com I FOR FURTHER TECHNICAL DETAILS ON THIS PRODUCT, REQUEST CATALOG REFERENCE E210 & N320 1.123 LINEAR ACTUATOR: COMPACT CYLINDER SERIES NCQ2/CQ2 A C C E S S O R I E S ( M M ) S E R I E S N C Q 2 / C Q 2 S I N G L E R O D C L E V I S ( R O D E Y E ) A C C E S S O R I E S ( M M ) S E R I E S N C Q 2 / C Q 2 D O U B L E R O D C L E V I S ( R O D E Y E ) CQ2 SINGLE ROD

1, Metal joint q, w End plate (D) !2, Connection bracket q, w, Gasket e, r, O-ring y, u End plate (D) !

terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46 54.5 60 52 48.5 101 54.5 68 22 40 81.5 36.5 11 15 32 20 19 M5 8 1/4, 3/8 VCL31 104 24 25 59 46 57 60 54.5 48.5 101 57

Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

Approx. 300 F D Approx. 280 D Q F C G (PF) 1/2 C R R E E B A H 2-P Port size 2-P A B H 2-M Port size 2-M Thread depth N L L K K Conduit terminal: T F (Q) 34 25 U R C G (PF) 1/2 E B A H D 2-P Port size (S) 2-M L K N.C.

terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R Q R Q R S Q R S 83 22 23 45 44 43 58 40.5 46.5 99 43 66 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 1/8 VCL21 86 22 23 46 44 44 58 41.5 46.5 99 44 66 18 36 67 31 8.5 12.5 28 18 12.8 M4 6 1/4 99 24 25 56.5 46 54.5 60 52 48.5 101 54.5 68 22 40 81.5 36.5 11 15 32 20 19 M5 8 1/4, 3/8 VCL31 104 24 25 59 46 57 60 54.5 48.5 101 57

For connector cable of M8 connector, refer to back page 10. 25 Series SYJ5000 Construction 2 position single 2 position double (A) 4 (B) 2 (A) 4 (B) 2 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) e w q t r q y t rw (A) 4 (B) 2 (A) 4 (B) 2 i 5 (R1) 1 (P) 3 (R2) 5 (R1) 1 (P) 3 (R2) i u 3 position closed center/exhaust center/pressure center 3 position closed center (B) 2 (A) 4 q t rw 5 (R1) 3 (R2

w q w VQ5100 VQ5101 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) q w e q w VQ5201 VQ5200 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) e e r q w r q w VQ5301 VQ5401 VQ5300 VQ5400 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 (A) 4 (B) 2 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) 1 (P) 5 (R1) 3 (R2) VQ5500 (A) 4 (B) 2 VQ5501 (A) 4 (B) 2 1 (P) 5 (

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area [mm] P: Pressure drop rate (P1P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures

(mm) Electrical entry P Port size A B C D E F H K L M N Model Grommet: G Conduit: C DIN terminal: D Conduit terminal: T Q R Q R Q R S Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 45 44 43 58 40.5 46.5 99 43 66 83 1/8 VCW21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 46 44 44 58 41.5 46.5 99 44 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 56.5 46 54.5 60 52 48.5 101 54.5 68 99 1/4

0 y t r q e u w !2 i !1 (A) 4 (B) 2 (A) 4 (B) 2 4(A) SOL.a SOL.b SOL.a SOL.b 5 (EA) 1 (P) 3 (EB) 5 (EA) 1 (P) 3 (EB) 2(B) o 5(EA)/3(EB) 1(P) Description No. Material Note Component Parts SJ2A60K with back pressure check valve Spool valve assembly 1 N.C. (Normally closed) Resin/H-NBR !0 y t r q e u q !2 i !1 Spool valve assembly 2 Resin/H-NBR N.O.

Grommet: G Conduit: C 2-M 2-M L L K Approx. 300 K Q F D Approx. 280 D Q F C R C G (PF) 1/2 R E B A H E 2-P Port size A H 2-P Port size B DIN connector: D Conduit terminal: T 2-M 2-M L L K Cable 6.8 to 10 K 27.5 F F Q (Q) 34 S 25 U R C R C G (PF) 1/2 (44) E B A H D (S) E G (PF) 1/2 B A H D 2-P Port size 2-P Port size N.C.

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.

(arrangement as seen from lead wire side) 2-M2.6 x 0.45 D-sub Connector Cable Assembly Terminal No. q !5 !4 @4 !3 !2 @3 @2 !1 !0 o i !6 !7 w e r !8 Lead wire color Dot marking Terminal no. @1 @6 @5 Black None q !9 Brown None w y t @0 u Red None e Orange None r Yellow None t Pink None y Circular Connector Cable Assembly Terminal No.

Dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size B D E F H K L M N A C Model Note) Q V R Q R Q R S Q R S U 22 23 45 44 43 58 40.5 46.5 99 43 66 83 13.5 28 31 56.5 12.5 28 14 12.8 M4 4.5 64 1/8 VCL21 22 23 46 44 44 58 41.5 46.5 99 44 66 86 18 36 31 58.5 12.5 28 18 12.8 M4 6 67.5 1/4 24 25 56.5 46 54.5 60 52 48.5 101 54.5 68 99 22 40 36.5 11 15 32 20 19

(mm) Electrical entry P Port size B C D E F H K L M N A Grommet: G Conduit: C Conduit terminat: T Model Q R Q R Q R S U 13.5 28 64 31 6.5 12.5 28 14 12.8 M4 4.5 22 59 44 50 99 50 66 83 1/8 VCS21 18 36 67.5 31 8.5 12.5 28 18 12.8 M4 6 22 62 44 53 99 53 66 86 1/4 22 40 81.5 36.5 11 15 32 20 19 M5 8 24 76 46 66.5 101 66.5 68 99 1/4, 3/8 VCS31 30 50 86 36.5 13.5 15 32 25 23 M5 8 24 80 46 71 101