85% RH (No condensation) MTS Square wave noise from a noise simulator (pulse duration 1s) 100V AC line 1500V, 24V DC line 36V I/O line 600V Noise resistance CC Vibration resistance Endurance 10 to 55Hz; amplitude 0.75mm; X, Y, Z for 2 hours each Impact resistance Endurance 10G; X, Y, Z directions, 3 times each Output delay time 5ms or less Power consumption 10VA (100V AC/50Hz) 5W Weight 250g
Input Signal Counting input, resetting signal Resetting Input RS and COM pin are short-circuited with 10 ms or above (Pulse input) Counting Speed 20 Kcps External Power Supply 12V10%, 60mA Control Output CEU1-D: NPN (30VDC, 50mA) CEU1P-D: PNP (30VDC, 50mA) Output Mode Comparison/hold/one-shot (100 ms fixed) Supply Voltage 24VDC 10% Output Delay Time 5 ms max Power Consumption 10VA Weight 250g
of Body Options Additional Weight 12 Unit: g 16 20 25 32 40 50 63 Bore size (mm) Bore size 12, 16 20 to 63 M F N MF FN Both ends tapped 6 7 7 6 7 17 Rod end width across flats 10 10 21 21 46 46 Rear boss mounting 2 3 5 7 13 25 With arm 13 32 100 100 200 200 350 350 Rear flange 133 153 166 198 345 531 Calculation method/Example MKG20-10RFN I Standard calculation: MKB20-10R 250g
fluid temperature -5 to 60oC (No freezing) Proof pressure 1.5MPa Operating pressure range 0.1 to 1.0MPa Color (Standard) Handle: Red Body: White Handle operation Pushing stroke 3.2mm 4.2mm Switching angle 90o Push force Note1) 10N or less Handle operating force Rotating torque Note1) 0.7N-m or less 1.0N-m or less 3.0N-m or less 3.0N-m or less 3.5N-m or less A (Flame resistant PBT 77g 129g 250g
one minute between external terminals and case Insulation resistance 2Mh or more (at 500VDC megameter) between external terminals and case Vibration resistance 10 to 500Hz vibration width 1.5mm or 9.8m/s2 to X, Y, Z directions 2 hours for each direction Impact resistance 980 m/s2 X, Y, Z direction, 3 times for each direction Cable Oil-proof chloroethylene cable (3.4, 0.2mm2, 5m) Weight 250g
standard Indication Operation lamp: Green when on + deviation indicator Power Supply Voltage DC12~24V Current Comsumption 30mA Output Type: ISA11 NPN open collector 30V 80mA ISA15 PNP open collector 30V 80mA Operating Temp Range 0~60C / 32~140F (no dew formation) Vibration Resistance 10G Proof Pressure 0.5MPa / 73PSI Proof Noise Direct input 1000Vp-p Pulse duration 1s pulse rise 1ns Weight 250g
Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160mA or less 170mA or less 290g 150mA or less 250g
150mA or less 1000VAC for 1min. between external terminal block and case 2M (500VDC) between external terminal block and case 1000Vp-p, Pulse width 1s, Rise time 1ns 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/s in X, Y, Z directions for 2 hours each Vibration resistance Impact resistance Weight Enclosure Piping port size 490m/s in X, Y, Z directions, 3 times each 250g
one minute between external terminals and case Insulation resistance 2Mh or more (at 500VDC megameter) between external terminals and case Vibration resistance 10 to 500Hz vibration width 1.5mm or 9.8m/s2 to X, Y, Z directions 2 hours for each direction Impact resistance 980 m/s2 X, Y, Z direction, 3 times for each direction Cable Oil-proof chloroethylene cable (3.4, 0.2mm2, 5m) Weight 250g
Repeatability Temperature characteristics Current consumption (No load) Weight Note 3) Port size (Rc, NPT, G) Detection type Indicator light Operating pressure range Proof pressure Accumulated flow range 0 to 50C 5% F.S. or less 1% F.S. or less 2% F.S. or less 3% F.S. or less (15 to 35C, based on 25C), 5% F.S. or less (0 to 50C, based on 25C) 160mA or less 170mA or less 290g 150mA or less 250g
(ripple 10% or less) 160mA or less 170mA or less 150mA or less 1000VAC for 1 min. between external terminal block and case 50M (500VDC) between external terminal block and case 1000Vp-p, Pulse width 1s, Rise time 1ns 10 to 500Hz at the smaller of amplitude 1.5mm or acceleration 98m/s in X, Y, Z directions, 2 hours each 490m/s in X, Y, Z directions, 3 times each 290g (without lead wire) 250g
Maximum load mass: 500g (horizontal), 100g (vertical) ; Maximum pushing force: 5.5N ; Strokes: 10, 20, 30 mm ; Weight: 130, 190, or 250g (stroke dependent) ; Positioning repeatability: ±5 µm (“F” resolution option) ; Parts measurement repeatability: ±10 µm (“F” resolution option)
Compact: width 20mm, Lightweight: 250g; Maximum clamping force: 200N, Maximum holding force: 300 N; Flat clamping characteristics: Outputs constant clamping force for workpiece thicknesses up to 3.5mm; Reduction of design/assembly labor by utilization; Arm assembly and mounting assembly have bee added to the clamp cylinder
Maximum load mass: 500g (horizontal), 100g (vertical) ; Maximum pushing force: 5.5N ; Strokes: 10, 20, 30 mm ; Weight: 130, 190, or 250g (stroke dependent) ; Positioning repeatability: ±5 µm (“F” resolution option) ; Parts measurement repeatability: ±10 µm (“F” resolution option)
Maximum load mass: 1000g (horizontal), 100g (vertical); Maximum pushing force: 5.5N; Strokes: 10, 20, 30 mm; Weight: 130, 190, or 250g (stroke dependent); Positioning repeatability: ±5 µ m (“F” resolution option); Parts measurement repeatability: ±10 µ m (“F” resolution option)
Compact: width 20mm, Lightweight: 250g; Maximum clamping force: 200N, Maximum holding force: 300 N; Flat clamping characteristics: Outputs constant clamping force for workpiece thicknesses up to 3.5mm; Reduction of design/assembly labor by utilization; Arm assembly and mounting assembly have bee added to the clamp cylinder
The rod type electric actuator LEY series has various body sizes with thrust equivalent to 16, 25, and 32 bore size. Direct or bracket mountings are available in three directions or types. Thrust, speed and positioning * can be managed with the use of an optional controller. Possible applications include transfer, opening and shutting, pressing, pushing, and press-fitting.Selectable mounting
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, ACTUATOR, ELECTRIC, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 7.05479 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, 25MM LE ELECTRIC ACTUATOR, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 10.58218 lb
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: 80mm, Stroke: 250mm, Rod End Thread: G (Long Male Rod End)