SMC Corporation of America
Elite Part Number Search
Search Results "LEY16DC-30C"

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

Given an ambient temperature of 30C and a relative humidity of 60%. Trace the arrow mark, from point A of ambient temperature 30C to obtain the intersection B on the curved line for the relative humidity of 60%. Trace the arrow mark, from the intersection B to obtain the intersection D on the curved line for the 0.7 MPa pressure characterisitics.

White 1 1 [C] Brown Brown 20 Yellow 2 2 Black Blue 22 PM Orange C3 CM 3 24 FAN 3 Blue Blue Blue 4 Brown 18 Red 5 [G4] Yellow/Green Yellow/Green [G3] Option DM (CN6) 2/3 (CN5) 3/3 Red Brown 5 1 2 Black 5 LS1 Red Blue 6 6 Black Red Brown 5 7 Yellow/Green LS2 4 8 Black Red Blue Black [G4] DI solenoid valve 1 Red Brown 15 FWD CM Black SVDI Blue 16 2 12 11 Option DM IV Water leakage detector 30C

BL Option U other than T1/Z/Z1 (CN2) (CN1) 1 1 3 3 2 2 4 4 3 2 1 3 2 1 4 4 2 1 1 3 2 1 6 8 3 5 7 2 4 2 1 1 3 2 USB Board PCB4 Display Board PCB3 BK BR RD RD RD RD BL BK BK RD RD WH Not connected at option Z 24COM AOUT +24V + OUT (CN1) 3 6 2 5 4 1 BR BR BL BL Option DM DI Sensor Level Switch Level Switch Water Leak Sensor BL BR WLS LS1 LS2 Solenoid Valve DI SVDI Option DM BL 11 FWD 12 CM 30C

degC Fig. 6-1 Cooling capacity 2) Heating capacity Fluid: water Fluid: water 1000 2000 900 Ambient 35C 1800 Ambient 30C 800 1600 Ambient 25C Heating capacity W Heating capacity W 700 1400 600 Ambient 20C 1200 500 Ambient 15C 1000 400 800 300 Ambient 15C 600 200 400 100 0 200 10 15 20 25 30 35 40 45 50 10 15 20 25 30 35 40 45 50 Circulating fluid temperature degC Fluid temperature degC Fig

ID20 ID30 ID40 ID60 Model 80 155 330 780 20 37 85 195 100 192 415 975 Recycled air flow rate Note) (L/min (ANR) Outlet air flow rate (L/min (ANR) Inlet air flow rate (L/min (ANR) Port size (Nominal size B) Weight (kg) 1 4 1 2 1 2 3 4 7 8.5 18.5 25 Supply dry air with a low dew point below 30C. Compact and lightweight without heater and electric control board.

Part Standard Replacement Operating Conditions Period Cooling Fan 4 to 5 years Smoothing Capacitor 7 to 8 years Surrounding Air Temperature: Annual average of 30C Other Aluminum Electrolytic Capacitor 5 years Load Factor: 80% max. Operation Rate: 20 hours/day max.

Part Standard Replacement Operating Conditions Period Cooling Fan 4 to 5 years Smoothing Capacitor 7 to 8 years Surrounding Air Temperature: Annual average of 30C Other Aluminum Electrolytic Capacitor 5 years Load Factor: 80% max. Operation Rate: 20 hours/day max.

(Refer to the instruction manual for details on the cleaning.) 42 47 49.5 40 39.5 43 44.5 34.5 35.5 36 38 40 41.5 10 12000 14000 HAW75 15000 18000 20 45 48.5 52 45 39 40 42.5 41 43 45.5 34.5 35.5 36 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C. Inlet air temperature 50C is saturated air.

Cool from 30C (303 K) to 20C (293 K). : Tap water Density g: 1 x 103 kg/m3 Specific heat C: 4.2 x 103 J/(kgK) Water bath * Refer to the information shown below for the typical physical property values by circulating fluid.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 * Shown above are reference values.

1.00 4.18 x 103 1.00 1 x 103 30C 1.01 3.91 x 103 1.01 0.94 x 103 35C 0.99 4.18 x 103 0.99 1 x 103 35C 1.01 3.91 x 103 1.01 0.94 x 103 40C 0.99 4.18 x 103 0.99 1 x 103 40C 1.01 3.92 x 103 1.01 0.94 x 103 Note) The above shown are reference values.

B/C 21 to 30 Force [N] 100 Lead 10: LEY16EA 80 LEY40E A 24 to 30 50 to 65% B/C 21 to 30 60 40 Min. 20% 0 20 10 0 20 30 40 50 60 70 Pushing force set value [%] Max. 65% Model LEY16mE LEY25mE LEY32mE LEY40mE Lead A B C A B C A B C A B C Ambient temperature Pushing force set value [%] Duty ratio [%] Continuous pushing time [min] 30C

(Refer to the instruction manual for details on the cleaning.) 10 12000 14000 40 HAW75 15000 18000 20 45 HAW110 Conditions: Air pressure 0.7 MPa, Cooling water temperature 30C Inlet air temperature 50C is saturated air.

Item CH1 CH2 Setting range 15 to 25 20 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.

Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.

Item CH1 CH2 Setting range 5 to 35 10 to 40 CH2 set temperature CH1set By default 20 25 temperature [Tips] Sample set temperature: To change from CH1SP: 25C and CH2SP: 30C status, to CH2SP: 15C, first set CH1SP to 15C and then CH2SP to 15C. If CH2SP is set to 15C before setting CH1SP to 15C, then the following message appears: Please set CH1SP first.