0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less Repeatability Note 1) 2% F .S. or less 1% F .S. or less Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F .S. or less (0 to 50C based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 1% F.S. or less (connected with PF2W33) Repeatability Note 1) 3% F.S. or less 3% F.S. or less (connected with PF2W2) 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics Pulse output, N channel, open drain, output for display unit PF2W3.
/ 14 to 122F -10 to 50C / 14 to 122F Max Operating 2 Position S & D 20Hz 5Hz OR CONTACT YOUR LOCAL SMC REPRESENTATIVE.
Inlet air temperature 5 to 50C IDF (For IDF100F to 150F, up to 60C is allowed.)
Note 2) Power supply 12 months continuous operation (without back lighting) Battery life 250ms Response speed 2% F.S. or less (Temperature conditions: at 25C) Display accuracy 1% F.S. or less (Temperature conditions: at 25C) Repeatability 3% F.S. or less (0 to 50C, based on 25C) Temperature characteristics M5 x 0.8 Piping port 0 to 50C (with no condensation) Ambient temperature 35 to 85%
Double Max 10ms Max 15ms 3-position Max 20ms Max 25ms Life 200 million cycles or more Ambient and Fluid Temperature ( N o t e 3 ) -10 to +50C (14~122F) -5 to +50C (23~122F) Lubricant ( N o t e 4 ) Not required Not required Manual Override Non-locking, Push Non-locking, Push Protection Dustproof Dustproof ( N o t e 2 ) Calculated on the basis of JIS B 8375-1981 (Supply pressure 0.5 MPa {5.1
0 to 50C Linearity Note 1) 5% F.S. or less 3% F.S. or less 2% F.S. or less 1% F.S. or less Repeatability Note 1) 2% F.S. or less (15 to 35C based on 25C), 3% F.S. or less (0 to 50C based on 25C) Temperature characteristics Pulse output, N channel, open drain, output for display unit PF2W3.
0 to 50C Linearity Note 1) 5% F .S. or less 3% F .S. or less Repeatability Note 1) 2% F .S. or less 1% F .S. or less Temperature characteristics 2% F.S. or less (15 to 35C based on 25C), 3% F .S. or less (0 to 50C based on 25C) Pulse output, N channel, open drain, output for display unit PF2W3.
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
SMC's series LER electric rotary table is available in a basic or high precision style, and features a low profile, space-saving design. A digital control allows easy setting of the angular speed, and angular acceleration/deceleration, etc. Rotation angle is possible up to 320° (310° on LER10). Up to 6.6 N·m of rotation torque (3.3 N·m of pushing torque available). The rotation speed
Table Accuracy: Basic Type, Max. Rotating Torque: J (Basic, 6.6 N.m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IP™), Mounting: 8 (DIN Rail)
Table Accuracy: Basic Type, Max. Rotating Torque: K (High Torque, 10 N▪m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IP™), Mounting: 8 (DIN Rail)
Table Accuracy: H (High-precision Type), Max. Rotating Torque: K (High Torque, 10 N▪m), Rotation Angle: 320°, Motor Cable Entry: Basic, Entry Right Side, Actuator Cable Type, Length: R5 (5m), Controller: C91 (Ether Net/IP™), Mounting: 8 (DIN Rail)
Table Accuracy: H (High Precision), Size: 30, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length
Table Accuracy: H (High Precision), Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w
Table Accuracy: Basic, Size: 10, Max. Rotation Torque: K (High Torque, LER10: 0.3; LER30: 1.2; LER50: 10), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC
Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w
Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6), Rotation Angle: LER10: 310°; LER30/LER50: 320°, Motor Cable Entry: Basic, Entry on the Right Side, Actuator Cable: R (Robotic Type Cables, Flexible Type), Actuator Cable Length: 5 (5), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IP™ Direct Input Type), I/O Cable Length for LEC: w