]) 20 40 60 30 45 60 Horizontal (2000 [mm/s2]) 30 60 70 40 60 80 Work load [kg] Note 2) For LECPA (3000 [mm/s2]) 12 30 30 20 40 40 (2000 [mm/s2]) 18 50 50 30 60 60 Actuator specifications Vertical Note 15) (3000 [mm/s2]) 7 15 29 10 21 42 Pushing force [N] Note 3) Note 4) Note 5) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 Speed [mm/s] Note 5) 18 to 400 9 to 200 5 to 100
Auto Switches Common Specifications Type Reed auto switch Solid state auto switch Leakage current 3-wire: 100 A or less, 2-wire: 0.8 mA or less None Operating time 1 ms or less (3) 1.2 ms Impact resistance 1000 m/s2 (4) 300 m/s2 Insulation resistance 50 M or more at 500 VDC Mega (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) 1500 VAC for 1 minute (1) (Between
S3 U0 U1 U2 U3 S0 S1 S2 S3 U0 U1 U2 U3 F F U0 U1 U2 U3 U0 U1 U2 U3 S0 S1 S2 S3 S0 S1 S2 S3 S0 S1 S2 S3 Without cable Without cable Without cable (2) (2) (2) (2) Kit Kit Kit Kit Kit Kit With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable (5 m) With cable (1.5 m) With cable (3 m) With cable
, 1200, 1500, 900, 1000, 1200, 1500, Stroke [mm] Note1) 900, 1000 1800, 2000 1800, 2000 1 10 19 LECP6/LECP1/LECPMJ/JXC91 Work load [kg] note2) Horizontal 1 5 14 LECPA Actuator specification 48 to 1100 48 to 1400 48 to 1500 Note2)Speed [mm/s] 3,000 Max.acceleration/deceleration [mm/s2] 0.08 Positioning repeeatability [mm] 0.1 or less Lost motion[mm] note3) Equivalent lead [mm] 48 48 48 50
For details, refer to SMC Best Pneumatics catalog vol. 8, page 8-30-31/8-30-32. 18 Series CY3 Auto Switch Specifications Auto Switch Common Specifications Solid state switch Reed switch Type Leakage current 3-wire: 100 A or less 2-wire: 0.8 mA or less None Operating time 1 ms or less 1.2 ms 300 m/s2 1000 m/s2 Impact resistance 50 M or more at 500 Mega VDC (between lead wire and case) Insulation
VAC for 1 min. between external terminal and case Insulation resistance 50 M (500 VDC) between external terminal and case 4.9 m/s2 10 to 500 Hz at whichever is smaller: 1.5 mm amplitude or 98 m/s2 acceleration in X, Y, Z directions for 2 hrs. each Vibration resistance 490 m/s2 in X, Y, Z directions 3 times each Impact resistance Noise resistance 1000 Vp-p, Pulse width 1 s, Rise time 1 ns
1000 80 80 0 0 1 2 2000 2000 100 100 0 0 3 4000 2000 70 60 500 1 4 -500 2000 60 70 1000 1 Position 5 1000 2000 80 80 0 0 control 6 2000 1000 80 80 0 0 7 1000 1000 80 80 0 0 Position command creation USB I/F CN1 CN3 D I/O con trol Personal Servo-on Start Failure, etc. computer USB Note 1.
[Normal mode] Step data example Pushing Pushing Moving In Position Acceleration Trigger LV AREA 1 AREA 2 No Movement Speed Deceleration force speed force position [mm/s2] [mm/s2] . mode [mm/s] [mm] [] [mm] [mm] [] [mm/s] [] [mm] 0 1 ABS 100 100.00 1000 1000 50 40 10 100 0 0 5 2 ABS 50 50.00 1000 1000 0 0 0 100 0 0 0.1 (E.g.) Flow chart Controller Select/input Step No.1.
Move mm/s mm mm/s2 mm/s2 mm/s mm mm mm 0 ABS 100 20.00 1000 1000 0 0 0 100 18.00 22.50 0.5 1 ABS 50 10.00 1000 1000 70 60 5 100 6.0 12.0 1.5 63 ABS 20 5.00 500 500 0 0 0 100 3.0 8.0 1.2 Caution Writing of the step data should be performed while the electric actuator is stopped 59 - Details of step data Setting name Range Description No. 0 to 63 Number of the step data.
) (900) (1000) (900) (1000) (1000) MY1C20 MY1C20 MY1C20 MY1C20 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 MY1C16 (900) (900) 20 10 0 1000 2000 3000 5000 4000 Support spacing (l ) (mm) 8-11-65 63 Series MY1C Construction: 16 to 63 $1 #3 !
Series CQ2 Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Stroke S2 Part no. denotation B Stroke S1 Part no. denotation A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com B + Stroke S2 B + Stroke S1 B + Stroke S2 B + Stroke S1 A + Stroke (S1 + S2)
1000 500 400 300 200 100 MY3A max.
VQ 1000/2000 Plug-in Unit Base Mounted VQ2000 The broken lines indicate DIN rail mounting style [D].
Change "Safe func set2" from "1000" to "0". Select the tag "Drive". Change "Safe func set2" parameter from "1000" to "0". OFF : 0 ON : 1000 Select download Select the "Download" button. The modified data is transmitted to the driver.
Slider type LEFS series 2.1 Specification LEFS25,32,40 AC servo motor (100W / 200W/400W/) Model LEFS25 LEFS32 LEFS40 Stroke [mm] Note 1) 50800 501000 1501200 Work load [kg] Note 2) Work load [kg] 10 20 20 30 40 45 30 50 60 Vertical 4 8 15 5 10 20 7 15 30 400 1500 900 450 1500 1000 500 1500 1000 500 401 500 1200 720 360 1500 1000 500 1500 1000 500 501 600 900 540 270 1200 800 400 1500 1000
Movement Speed Position Acceleration Deceleration Force Value Area 1 Area 2 In pos force speed force mode mm/s (mm) mm/s2 mm/s2 (mm) (mm) (mm) mm/s 0 1 Absolute 100 100.00 1000 1000 50 40 10 100 0 0 5 2 Absolute 50 50.00 1000 1000 0 0 0 100 0 0 0, 1 (E.g.) Flow chart Controller (1) Select/input Step No.1.
50 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 6000 63 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 Made to Order Specifications (For details, refer to page 10-21-1.)
(Manufacturable stroke range: LEJS63-M/ 790 to 1790mm) Note13) The return to origin of stopper type can not be used. 15 - Product Weight Series LEJS40 Stroke [mm] 200 300 400 500 600 700 800 900 1000 1200 Weight (kg) 5.6 6.4 7.1 7.9 8.7 9.4 10.2 11.0 11.7 13.3 Extra weight of lock (kg) S2:0.2 / S6:0.3 / T6:0.2 Series LEJS63 Stroke [mm] 300 400 500 600 700 800 900 1000 1200 1500 Weight (kg
Please contact SMC regarding the performance. 29 Minimum bending radius [mm] (Reference values) Impact resistance Switch: 1000 m/s2, Connector: 300 m/s2 Insulation resistance 50 M or more (500 VDC measured via megohmmeter) (between lead wire and case) Withstand voltage 1000 VAC for 1 minute (between lead wire and case) Ambient temperature 10 to 60C Enclosure IEC60529 standard IP67