Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Standard Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: NPN Controller, LECP1, Programless Type, I/O Cable Length for LEC: 1.5m, Controller Mounting: -, Communication
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: PNP Controller, LECA6, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: PNP Controller, LECA6, Step Data Input Type, I/O Cable Length for LEC: 1.5m, Controller Mounting: DIN Rail
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: None, Actuator Cable Length: Without Cable, Controller Type - LEC, JXC: PNP Controller, LECA6, Step Data Input Type, I/O Cable Length for LEC: -, Controller Mounting: -, Communication
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: PNP Controller, LECP1, Programless Type, I/O Cable Length for LEC: 1.5m, Controller Mounting:
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting: Screw
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 5m, Controller Type - LEC, JXC: JXC91, EtherNet/IPâ„¢ Direct Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Robotic Flexible Cable, Actuator Cable Length: 1.5m, Controller Type - LEC, JXC: JXCL1, IO-Link, I/O Cable Length for LEC: Without Cable, Controller Mounting: DIN Rail Mounting
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXC61, Parallel PNP, Step Data Input Type, I/O Cable Length for LEC: Without Cable, Controller Mounting:
Body Size: 25, Type: In-line Motor Type, Motor: Step Motor (Servo DC24V), Lead Screw: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm, Lock: None, Body Option: Basic, Mounting: w/o Side Holder, Actuator Cable: Standard Cable, Actuator Cable Length: 3m, Controller Type - LEC, JXC: JXCE1, EtherCAT®, I/O Cable Length for LEC: Without Cable, Controller Mounting: DIN Rail Mounting, Communication
Parallel I/O Type: NPN, I/O Cable Length, m: 1.5, Option: Screw Mounting, Actuator: Electric Slide Table, High Rigidity Type, Size: 25, Type: In-line Motor Type, Lead: Size 8: 4mm, Size 16: 5mm, Size 25: 8mm, Stroke: 50mm
LECP1 series is a programless controller capable of setting up an electric actuator operation without using a PC or teaching box. Through the combination of parallel I/O inputs, 14 points of positioning are available. The speed and acceleration of the positioning can be set by the switch for each operating direction. A single signal sent to a dedicated terminal returns an actuator to
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: w/o Cable, Option: D (DIN Rail Mounting), Actuator Series: LER (Rotary Table), Table Accuracy: Basic, Size: 30, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6)
Controller Series: LECP1 (Programless Controller), Parallel I/O Type: P (PNP), I/O Cable Length, m: w/o Cable, Option: D (DIN Rail Mounting), Actuator Series: LER (Rotary Table), Table Accuracy: Basic, Size: 50, Max. Rotation Torque: J (Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6)
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Option: DIN Rail Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 30, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Controller Series: Programless Controller, Parallel I/O Type: PNP, I/O Cable Length, m: w/o Cable, Option: DIN Rail Mounting, Actuator Series: Rotary Table, Table Accuracy: Basic, Size: 50, Max. Rotation Torque: Basic, LER10: 0.2; LER30: 0.8; LER50: 6.6, Rotation Angle: -
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP NPN, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 1.83718 lb
Series LECP6 controller has two available modes for the setting software and teaching box.? In the easy mode, the operation can be started by only setting the speed, position, etc.? Using the normal mode allows a further detailed setup.??A few of the?main functions of the LECP6 controller are actuator control, specified force operation, separated power supply, and returning the actuator
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CONTROLLER STEP PNP, ACTUATOR, ELECTRIC ACTUATOR, IC, 25MM LE ELECTRIC ACTUATOR, 0.37478 lb