105 130 150 190 212 236 30 35 35 40 40 50 50 56 59 67 73 77 85 69 78 84 92 100 44 52 64 78 92 115 128 144 16 20 20 25 30 36 36 40 42 50 59 76 92 100 112 118 27 32 32 37 37 47 47 53 40 50 55 65 80 90 90 90 60 70 86 102 116 145 161 182 32 40 40 52 52 59 59 59 43 43 43 9.0 9.0 11.5 13.5 13.5 19 19 19 112.5 121 133 141.5 150 167 Bore (mm) W/o rod boot W/ rod boot KA N H1 K MM GA FV J W M S M1
How to Order [Option] XLGV M9N 16 A 1 G L Flange size 16, 25, 40 1 q e u r t XLGV M9N 50 A 1 G L Flange size 50, 63, 80 i w y o !0 !
Series Variations Series Size Page 25 32 40 63 Slider Type Ball Screw Drive LEFS Series 784 100 W 200 W 400 W Slider Type Belt Drive LEFB Series 805 100 W 200 W 400 W High Rigidity Slider Type Ball Screw Drive LEJS Series 824 100 W 200 W Rod Type LEY Series 848 100 W 200 W 400 W Guide Rod Type LEYG Series 864 100 W 200 W The values in shows the equivalent motor capacity. 780 LE Series Compatible
40 27 32 32 37 37 Bore (mm) X W S PW PL PH PG P N MM LZ LY LX LT LS LH LD KA K J H1 40 50 63 80 100 1/4 3/8 3/8 1/2 1/2 8 0 0 0 0 27 27 34 44 43 45 50 60 70 80 153 168 182 208 226 11 10 13 15 15 20 21 23 23 25 42 46 48.5 55 56.5 M14 X 1.5 M18 X 1.5 M18 X 1.5 M22 X 1.5 M26 X 1.5 27 30 31 37 40 70 80 93 116 133 81 90 106 131 148 42 50 59 76 92 3.2 3.2 3.2 4.5 6 207 222 250 296 312 40 45 50
Power supply 20 Single-phase 200 to 230 VAC (50/60 Hz) Water-cooled Refrigeration HRR U W 20 012 (UL Standards) Cooling capacity Option 2 (p. 35) 012 1000/1200 W (50/60 Hz) 018 1600/1800 W (50/60 Hz) 024 2000/2400 W (50/60 Hz) 030 2500/3000 W (50/60 Hz) Nil None Y With feet/Without rack mounting brackets Z*1 Without either a flow sensor, water leakage sensor, particle filter, bypass valve
Bore size (mm) Contents 32 40 50 63 80 100 32 40 50 63 80 100 MBB32-PS MBB40-PS MBB50-PS MBB63-PS MBB80-PS MBB100-PS MBB32-PS-W MBB40-PS-W MBB50-PS-W MBB63-PS-W MBB80-PS-W MBB100-PS-W Set of the No. @9, #0, #1, #2 and #3. Set of the No. @9, #0, #1, #2 and #3. D-X Seal kits consist of items @9 to #3, and can be ordered by using the seal kit number corresponding to each bore size.
P (cm) Mounting Applicable max. stroke according to buckling strength (cm) Operating pressure (MPa) Support bracket nominal symbol and schematic diagram Nominal symbol 125 140 160 Foot: L Rod flange: Head flange: 0.3 103 92 113 F G L, F 0.5 79 70 86 W W W 0.7 66 58 72 0.3 45 38 47 G 0.5 33 27 34 0.7 26 22 27 Center trunnion: 0.3 96 83 106 T Clevis: C, D C, D 0.5 71 61 76 W W 0.7 59 50 62
Hz 7.5 VA Note) Apparent power AC CE2 50 Hz 7.0 VA Holding 60 Hz 5.5 VA ML2B 6 W Power consumption Note) DC Note) At the rated voltage.
Hz 7.5 VA Note) Apparent power AC CE2 50 Hz 7.0 VA Holding 60 Hz 5.5 VA ML2B 6 W Power consumption Note) DC Note) At the rated voltage.
200 W 400 W 100 W 200 W 400 W CC-Link direct input type (For absolute encoder) S1 S3 S4 S5 S7 S8 C Incremental SSCNET III type (For absolute encoder) S AC servo motor (S6) AC servo motor (S7) AC servo motor (S8) Absolute Power supply voltage 1 2 100 to 120 VAC, 50/60 Hz 200 to 230 VAC, 50/60 Hz Only available for power supply voltage 200 to 230 VAC.
C85 C85W C85 C85K C85K C85R C75 C75W C75 C75K C75K C75R Single foot: Cl85Nl lTL (With mounting bracket) (W + Stroke) LT Standard NH LT 2 x AB (XS + Stroke) Double foot: Cl85Nl lTM (With mounting bracket) (W + Stroke) LT 4 x AB UR (XL + 2 x Stroke) LS + Stroke AV AO US TR [mm] Bore size AB AO AV LS LT NH TRJs14 UR US (W) (XS) (XL) 1 to 50 51 to 100 101 to 150 1 to 50 51 to 100 101 to 150
Dynamic moment Va V : Collision speed Va : Average speed Calculation Example Operating Conditions Cylinder: CY1H15 Cushion: Standard (Adjusting bolt) Mounting: Horizontal wall mounting Speed (average): Va = 300 [mm/s] Load mass: W = 1 [kg] (excluding mass of arm section) L1 = 50 [mm] L2 = 50 [mm] W L2 L1 Item Load factor n Note zMaximum load mass W 1 = W/Wmax = 1/9 = 0.111 Examine W.
However, setting "0" will be 50%. Example: When you set "50" to the parameter, the filter will be readjusted at the 50 [%] time of 50% or more oscillation level.
connector LO 110 VAC 50/60Hz 5000mm 50 3 With lead wire M [115 VAC 50/60Hz] M plug connector Without lead wire MN 220 VAC 50/60Hz 4 Without connector MO [230 VAC 50/60Hz] Without connector cable WO M8 connector For type "W", DC voltage is only available.
, 50, 75, 100, 125, 150, 200 MB 40, 50, 63 25, 50, 75, 100, 125, 150, 200, 250, 300 Please consult with SMC for strokes which exceed the standard stroke length.
1 q r e w t i y u o !0 !
D 2.8 x P 0.3 x Wcos + Wsin D 5.0 x P 0.3 x W + W D 5.0 x P 20Data W W > Wv P > Pv Determination of allowable load weight & pressure Inclined operation (For vertical operation, refer to page 8-15-50.)
(Power consumption) 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA (2.1 W)/50 Hz, 2.3 VA (1.5 W)/60 Hz Inrush Holding AC 1.8 W (2.04 W: With light/surge voltage suppressor) Power consumption DC Conduit terminal Grommet terminal, DIN terminal Plug-in type Non plug-in type Electrical entry Note 1) Use dry air at low temperatures.
Applicable strokes are available in 5mm increments. 34 Compact Hydraulic Cylinder Double Acting/Double Rod Series CHQWB 20, 32, 40, 50, 63, 80, 100 3.5MPa How to Order B B 50 30 D CHQ CHDQ 50 30 A72 D W W With Auto Switch With auto switch (built-in magnet) Number of auto switches 2 pcs. 1 pc. "n" pcs.