EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.
For (Built-in one-touch fitting) C4 N3 4 L2 L1 For M5 Manual override 10 12.3 35 15.5 91.7 [96.1] 0.2 34.2 78.8 [83.2] 36.5 17 12.5 57.2 [59.4] P R P R A A A A A 31.5 56.4 [58.6] B B B B B (4.4) 2-4.5 (For mounting) (Pitch) P = 10.5 (Station 1) (Station n) 15.5 L1 L2 4.5 (Station 1) (Station n) 15.5 (Light/surge voltage suppressor) (Light/surge voltage suppressor) + + + + + + + + + + B B
Formula: L1 = 16n + 57, L2 = 16n + 176 (For one input block.
L1, L2 max. overhang = 45 mm w Confirm that L1 and L2 are lower than the max. overhang. L1 = 20 mm and L2 = 30 mm OK (L1, L2 max. overhang = 45 mm) Selection method q Find the max. overhang of L1 and L2 from the selection graph. L1: Find the L at an operating pressure of 0.5 MPa from the graph, and multiply it by 1/2.
except A, L and L1 are same as front flange type.
L1 = M x 12.5 + 23 L2 = L1 10.5 L4 = (L1 L3)/2 2 15.6 30.6 3/5 2 2 2 2 2 1 4 4 4 4 4 D D D D D One-touch fitting One-touch fitting [1(P), 3/5(E) port] Applicable tubing O.D: 8, 5/16" [4(A), 2(B) port] n1: Piece of the SJ2000 n2: Piece of the SJ3000 Applicable tubing O.D: 2, 1/8" 4, 5/32" One-touch fitting [4(A), 2(B) port] The dimensions of L1 to L4 for SS5J3-M60S6BlDStations D are the
A A1 RR1 A1 E1 L1 MM RR1 U1 NZ L Part no.
L3 Max. 1 4 1 2 L1 L2 D Min. L3 Max.
of the nut (E),L1,L2: Nut material PVDF dimensions L1 C Applicable tubing O.D.
L1 D KK 3 x applicable tubing Plug-in Elbow: KQ2L D Applicable tubing O.D.
78.5 42.5 DIN rail holding screw (For DIN rail mounting) (Station n1) (Station 1) (Station 1) (Station n2) Light/surge voltage suppressor Individual SUP spacer Individual EXH spacer 63.5 60 52.5 12 (For DIN rail mounting) (7.5) n1 = Valve stations n2 = Input block stations L2 = L1 10.5 L3 = 16 x n1 + 60 L4 = L3 + 81 + 21 x n2 L5 = (L1 L4)/2 L6 = 16 x n1 + 48 L7 = 21 x n2 + 81.5 L1: DIN
In this case, please note that dimensions, L1 and L2 on pages 160 and 161 may vary slightly.) For other components, refer to the SY series of the WEB catalog.
A A1 RR1 E1 L1 MM U1 Part no.
EX260 Serial transmission Calculation of dimensions L1 = 12.5 x n1 + 16 x n2 + 88.7 L2 = 12.5 x n1 + 16 x n2 + 48 M = L1/12.5 + 1 Remove all numbers after the decimal.
CRB2 CRB2 Q1 = M Q1 = M CRB1 L1 = L1 = MSU L1 L1 Q1 Q1 CRJ Not available for size 10 Not available for size 10 The maximum dimension L1 is, as a rule, twice the thread size. (Example) For M5: L1 max. = 10 mm The maximum dimension L1 is, as a rule, twice the thread size.
Standard: Double shafts (W) (mm) (mm) (mm) Size L1max X-2.5 X-3 X-3.5 X-5 L1max Y-2.5 Y-3 Y-3.5 Y-5 L2 L1 + 1.5 L1 + 1.5 L1 + 2 L1 + 3 L2 L1 + 1.5 L1 + 1.5 L1 + 2 L1 + 3 Y 4 to 8 4.5 to 9 5 to 10 7 to 13 X 1 to 3 1.5 to 6.5 1.5 to 7.5 2 to 8.5 Y 1 to 19 1.5 to 15.5 1.5 to 22.5 2 to 26.5 Size 10 15 20 30 Size 10 15 20 30 X 4 to 14 4.5 to 18 5 to 20 7 to 22 10 15 20 30 Symbol: A23 The shaft
Allowable dynamic moment Model Mounting orientation LJ1H20 Actuator rating Load movement direction 8kg 500mm/s 600mm Work load Maximum speed Maximum stroke 600 400 L1 (mm) a = 1000 Pitching Yawing Vertical Vertical m a a = 2000 a = 3000 200 LJ1H2022PA-K (Power supply voltage 200VAC) L1 Mep 0 5 10 15 Transfer load m (kg) When an actuator is operated under conditions that exceed the lines in
Slave unit 75 Slave unit 03 Slave unit 01 Master unit ZW-31LM SI unit Master unit SI unit Master unit SI unit SI unit SHIELD SG L2 L1 SHIELD SG L2 L1 SHIELD SG L2 L1 SG L2 L1 + + FG + + FG + + + + + + SHIELD FG FG + Twisted pair wire with shield Class 3 ground Class 3 ground Class 3 ground Class 3 ground FG FG b) 3 wire type Wiring does not include signal ground line (SG).
VVQ1000-1A-3Electrical entry F1: For F kit P1: P, G, T, S kit for 1 to 12 stations/Double wiring P2: G, S kit for 13 to 16 stations/Double wiring P3: G, S kit for 1 to 16 stations/Single wiring L0: L0 kit L1: L1 kit L2: L2 kit Lead wire assembly for extensions is attached. Note) Note) Note) Note) : Stations (1 to 16)
(mm) L1 Manual override Stations n L1 L2 L3 L4 2 stations 135.5 125 100 17.5 3 4 5 6 7 8 9 10 stations (Press and turn for the locking type.)