Body Size: 30, Semi-Standard: P (0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale)
Body Size: 40, Semi-Standard: P (0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale)
Body Size: 20, Semi-Standard: P (0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale)
Body Size: 50, Semi-Standard: 0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale
Body Size: 30, Semi-Standard: 0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale
Body Size: 40, Semi-Standard: 0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale
Body Size: 20, Semi-Standard: 0.1 to 0.4 MPa; 0.5m Lead Wire; MPa/psi Dual Scale
Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).Weight: 62g (16% lighter than IS1000), Overall height: 52mm (11% smaller than IS1000), 100V AC/DC specifications, Service life: 5 million cycles, Can be connected to modular type FRL units, RoHS compliant & CE marked, PRESSURE SW AC50/60 ONLY *LQA, INSTRUMENTATION, IS/NIS PRESSURE
Also available are the IS10M (pressure switch with spacer) and the IS10E (pressure switch with piping adapter).For connecting to modular type FRL units , 100V AC/DC specifications , Service life: 5 million cycles , RoHS compliant & CE marked, N, IS, "PRESSURE SWITCH, N lb
The standard IS10M pressure switch cannot be set to 0.4 to 0.45 MPa because 0.4 MPa is the upper limit of the set pressure range.
For AC-A/AC-B series modular F.R.L units with a white body, the pressure switch must be replaced with an IS10M-□-6-A pressure switch (set pressure: 0.1 to 0.6 MPa).
Size: 60, Options: L (3m Lead Wire Length)
Size: 60, Options: 6 (0.1 to 0.6MPa Set Pressure Range)
Size: 60, Options: Z (5m Lead Wire Length)