In the case slide table is stopped at intermediate positions by the external stopper then forwarded to the front, after slide table is returned to the back for just a moment to retract the stopper, supply pressure to the opposite port to operate slide table. 3. Do not use it in such a way that excessive external force or impact force could work on it. This could result in damage.

Included in the manifold block assembly. Included in the manifold block assembly. Round head combination screw Manifold gasket Clamp sub assembly DIN rail Refer to page 102. Since in the part number corresponds with the number of stations, fill in the number of stations (4 to 12). Refer to page 90.

Out: Cylinder extend In: Cylinder retract In Out Theoretical Output Table The dual rod ensures an output twice that of standard cylinders.

In locations having corrosive gases, organic solvents, and chemical solutions, or in locations in which these elements are likely to adhere to the equipment. 2. In locations in which salt water, water, or water vapor could come in contact with the equipment. 3. In locations that are exposed to direct sunlight.

Solenoid valve Enter an "X" in the sections for valves to be used. In case of mixed port sizes, indicate by entering C4, L6, etc. In case of a manifold with external pilot specifications, enter an "X" in valve locations where an external pilot is required. Mixed internal and external specifications are also possible in this section.

If an excessive force is applied on the connector in the LOCK position, the connector block may be damaged. Also, using in such a way that the connector floats in the FREE position, it may cause the lead wire, etc. to break. Thus, refrain from using in these ways.

In such a case, use external pilot type. (When throttling IN port, or operating with OUT port open to the atmosphere or in a similar operation.)

INFORMATION Electric Actuator/Slider Type Motor Parallel Type RoHS Reduced in overall length Reduced in height Reduced dimension Parallel Parallel In-line Reduced dimension In-line Size Length reduction (mm) Motor mounting position (mm) Parallel In-line 16 80.5 416.5 497 25 75 460.5 535.5 32 87 495 582 40 102.6 553.4 656 Size Length reduction (mm) Motor mounting position (mm) Parallel In-line

case of Locking type, turn after pushing in.

Note 2) Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000 Hz. Test was performed in both energized and de-energized states in the axial direction and at right angles to the main valve and armature.

conditions that exceed the lines in the graphs above, be sure to use a regenerative absorption unit.

Tightening the screws with a higher torque than recommended may result in a malfunction and/or decrease in guide accuracy, while tightening with a lower torque can result in the displacement of the mounting position or, in extreme conditions, the actuator could become detached from its mounting position.

In the case of large bore cylinder, even when the lock is released, operational resistance as shown in the table below is generated in a non-load state. CLQ MLGP RLQ Maintenance Caution MLU 1.

Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or other applications unsuitable for the standard specifications described in the

In case of exceeding the following strokes, the cylinder is in the scope of the second class pressure vessel.

No malfunction occurred in a one-sweep test between 8.3 and 2000Hz. Test was performed at both energized and de-energized states to the axis and right angle directions of the main valve and armature. (Value in the initial stage.) Vibration resistance: Values in case of high pressure style (1.5W). Values in case of low wattage (0.5W) .

the desired direction (4 directions in 90 increments).

conditions that exceed the lines in the graphs above, be sure to use a regenerative absorption unit.