Circulating Fluid: Ethylene Glycol Aqueous Solution, -20 to 90°C, Option: Circulating Fluid Automatic Recovery
Circulating Fluid: Ethylene Glycol Aqueous Solution, -20 to 90°C, Option: D+N+Y+Z
Circulating Fluid: Ethylene Glycol Aqueous Solution, -20 to 90°C, Option: C+N+Z
Cooling Capacity: 10 kW, Communication: None, Option: -
Cooling Capacity: 10 kW, Communication: DeviceNetâ„¢, Option: -
Cooling Capacity: 10 kW, Communication: None, Option: Circulating Fluid Automatic Recovery
Cooling Capacity: 10 kW, Communication: None, Option: NPT Fitting
Cooling Capacity: 10 kW, Communication: None, Option: N+Z
Cooling Capacity: 10 kW, Communication: Analog, Option: NPT Fitting
Cooling Capacity: 10 kW, Communication: DeviceNetâ„¢, Option: DI Control Kit
Cooling Capacity: 10 kW, Communication: DeviceNetâ„¢, Option: Y+Z
Cooling Capacity: 10 kW, Communication: C+D, Option: NPT Fitting
Cooling Capacity: 10 kW, Communication: None, Option: N+Y
Cooling Capacity: 10 kW, Communication: Analog, Option: DI Control Kit
Cooling Capacity: 10 kW, Communication: C+D, Option: W+Y+Z
Cooling Capacity: 10 kW, Communication: None, Option: DI Control Kit
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
The HRZ series thermo-chiller is a high performance device for circulating fluid with a constant temperature. Available in 3 temperature range designs so the best chiller can be selected for operating temperature needs. No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, HRZ010-WS PCW VALVE, HRZ, REFRIGERATED THERMO-COOLER, 0.00000