No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Condenser Assy for HRZ008-L(1), REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circulating Pump for HRZ008-L-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Circuit Protector for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Motor Breaker Assy for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Magnetic Contactor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Pump Inverter for HRZ008-L-F, REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Pump Inverter for HRZ008-L1-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Compressor for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER, 737
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover R for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Cover L for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER,
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Tank Insulation for HRZ008-L(1)-F, REFRIGERATED THERMO-COOLER
CRATE FOR HRZ008, HRZ004, AMAT, REFRIGERATED THERMO-COOLER, 737, 149 lb
No ventilation holes on the right or left sides make tight fitting installation possible, since contact can be made with other equipment or walls.Cooling method: water-cooled refrigeration, Circulation fluid: clear water, deionized water, Main tank capacity: approximately 15 , Circulating fluid recovery tank: approximately 16, Casters (496, 498, HRZ008-L/L1, & HRZD), REFRIGERATED THERMO-COOLER
Ht BY IA 43 25 40 Max.Wc 36 35 13 D 30 Width across flats K Ws Width across flats 44 Clevis width CLK1A: 16.5 R15 0.050 0.093 +0.027 0 Shaft: 12d9 Hole: 12H8 F +0.3 0 +0.4 0 CLK1B: 19.5 Z + Stroke S + Stroke 1.5 27 2 40 57 97 ZZ + Stroke Approx.
Ht BY IA 43 25 Max.Wc 40 36 35 13 D 30 Width across flats K Ws Width across flats 44 R15 Clevis width CLK1A: 16.5 0.050 0.093 +0.027 0 Shaft: 12d9 Hole: 12H8 F +0.3 0 +0.4 0 CLK1B: 19.5 Z + Stroke S + Stroke 1.5 27 2 40 57 97 ZZ + Stroke Approx.
(WS (WS (WS VS) VS) VS) VS) M12 M12 M12 M12 ( ( ( ( ) ) ) ) (WS (WS (WS (WS VS) VS) VS) VS) (WZ (WZ (WZ (WZ VZ) VZ) VZ) VZ) (WZ (WZ (WZ (WZ VZ) VZ) VZ) VZ) 8 SGC200*-OMJ0004-A SGC/SGH Series SGC/SGH Series SGC/SGH Series SGC/SGH Series/ / / / M12 M12 M12 M12 IP65() M12 IP65() (0.40.6Nm) IP65 30N IP65 M12 M12 M12 M12 ) M12 M12 M12 M12 M12 (4.5~7) IP65() 4.57()JIS C 3306
Mounting nut Rod end nut C NN B 0 0.3 FY FB KA MM Z + Stroke S + Stroke H A F NA F NB FT FZ FX B 0 0.3 2 x FC Mounting hole Rod section Refer to page 376 for details of the mounting nut.
FV FT L1 2 x FD FX FZ L2 + Stroke B + Stroke A + 2 (Stroke) Rod end male thread Rod End Male Thread (mm) Switch Bore size (mm) A1 L3 L4 12 16 20 25 63.2 67 73 84 24 25.5 28.5 32.5 14 15.5 18.5 22.5 L3 L4 + Stroke A1 + 2 (Stroke) Flange Bore size (mm) Stroke range (mm) (mm) A FD FT FV FX FZ L1 L2 B 12 16 20 25 5 to 30 42.2 25.2 4.5 5.5 25 45 55 13.5 3.5 5 to 30 43 26 4.5 5.5 30 45 55 13.5