diagnosis 1 EX600-WEN# (Unit 0) Valve output: 16 points byte 1 System diagnosis 2 Base byte 2 System diagnosis 3 DY#B (Unit 2) byte 3 System diagnosis 4 Reserved byte 4 DX#D (Unit 1) byte 5 EX600-WSV# (Unit 0) Base Valve output: 32 points byte 6 Reserved Remote (Wireless channel 001) byte 7 Reserved DY#B (Unit 3) byte 8 DX#D (Unit 1) byte 9 Reserved DY#B (Unit 3) byte 10 Remote (Wireless
diagnosis 1 EX600-WPN# (Unit 0) Valve output: 16 points byte 1 System diagnosis 2 Base byte 2 System diagnosis 3 DY#B (Unit 2) byte 3 System diagnosis 4 Reserved byte 4 DX#D (Unit 1) byte 5 EX600-WSV# (Unit 0) Base Valve output: 32 points byte 6 Reserved Remote (Wireless channel 001) byte 7 Reserved DY#B (Unit 3) byte 8 DX#D (Unit 1) byte 9 Reserved DY#B (Unit 3) byte 10 Remote (Wireless
#E/F) EX600-DY#E/F (15 byte) Byte Bit Parameter Setting value 0..3 Unit No. 0..8 0 4..7 Parameter type 1 1 0..7 Unit ID EX600-DY#E: 18 (Hex) EX600-DY#F: 1A (Hex) Unit parameter 0 Reserved 0 1 Monitor short circuit (out) 0: disable, 1: enable 2 2 Reserved 0 3 Restart after output load short circuit 0: manual, 1: auto 4..7 Reserved 0 Channel parameter Channel 0 to 7 0 (Ch0 output) Monitor
*B (8 points) 0 8 Digital output unit EX600-DY *E (16 points) 0 16 (EX600 Series) DY EX600-DY *F (16 points) 0 16 EX600-DM *E (8/8 points) 8 8 Digital I/O unit (EX600 Series) DM EX600-DM *F (8/8 points) 8 8 Analog input unit AX EX600-AXA*1 (2 points) 32 0 Analog output unit AY EX600-AYA*1 (2 points) 0 32 Analog I/O unit AM EX600-AMB*1 (2/2 points) 32 32 *1: User set minus ranges are not
The power supply for control and input, or the input device, is Off. 10 to 57 Hz: constant amplitude 0.75 mm p-p 57 to 150 Hz: constant acceleration 49 m/s2 DX E/DX F DY B/DY E/DY F Content Content Content DM E/DM F ST: STatus display LED ST: STatus display LED ST: STatus display LED
-byte output 2-byte output 2-byte output Wireless master module construction Input data: [Unit 1] Digital input unit (EX600-DX#D): 2 bytes occupied Output data: [Unit 0] Digital output unit (EX600-DY#B): 1 byte occupied [Unit 2] Wireless master unit (EX600-WEN#): 2 bytes occupied Unit 0 Unit 1 Unit 2 Unit 3 DY#B AXA DX#D EX600-WSV# Wireless slave unit setting parameter (Wireless channel 001
Digital output unit (EX600-DY or EX600-DM) Table. Module Output Data (DY or DM) Index Name / Meaning Type Flags Value 70x0:0 Slot x: Digital Outputs USINT RO Number of channels 70x0:01 Channel 0 BOOL RO P FALSE (OFF) TRUE (ON) : x: Slot No. Analogue output unit (EX600-AYA or EX600-AMB) Table.
Unit type Unit symbol Displayed unit symbol Part number EX600-DXB EX600-DXC EX600-DXC1 DX (8DI) Digital input DX EX600-DXD EX600-DXE EX600-DXF DX (16DI) DY (8DO) EX600-DYB DY (16DO) EX600-DYE EX600-DYF Digital output DY DY (24DO) EX600-DYE1 Digital I/O DM DM (8DI8DO) EX600-DME EX600-DMF Analog input AX AX (2AI) EX600-AXA Analog output AY AY (2AO) EX600-AYA Analog I/O AM AM (2AI2AO) EX600-
SI"PWR"LED 24 V10 1 POWER LED 2 ERROR LED EX600 LCD 3 LCD LCD Warning System access is not completed." 4 Ex600 SI"ST(M)"LED/ SI 5 " EX600 SI"ST(M)"LED/ 6 -50No.EX-OML0010CN-C 0 1 2 3 4 5 6 7 8 9 ON/OFF 1015 16 17 18 19 () 20 () 21 22 23 -51No.EX-OML0010CN-C SI EX600-DXB EX600-DXC EX600-DXC1 DX(8DI) DX EX600-DXD EX600-DXE EX600-DXF DX(16DI) DY(8DO) EX600-DYB DY(16DO) EX600
Clear UP to 1.5 0.08 to 0.5 (AWG28 to 20) XN2A-1430 t Replacement fuse Replacement fuse for the input unit (EX510DX) and the output unit (EX510-DY). The cable may be pulled out if the pulling force is 12 N or greater. Fuse Electrical specifications EX9-FU10 EX9-FU50 Part no.
#B (8 outputs) (16 bit) 16 bit2 EX600-DY#E (16 outputs) (16 bit) 16 bit Digital output unit EX600-DY#F (16 outputs) (16 bit) 16 bit EX600-DM#E (8 inputs / 8 outputs) 16 bit2 16 bit2 Digital I/O unit EX600-DM#F (8 inputs / 8 outputs) 16 bit2 16 bit2 Analogue input Unit EX600-AXA (2ch) 4 word3 (4 word) Analogue output Unit EX600-AYA (2ch) (4 word) 4 word3 Analogue I/O Unit EX600
#E DY#B DY#B DX#D DX#D DX#D DX#D DM#F SEN -79No.EX-OMS0026CN [SYSTEM CONFIGURATION STATUS] [LOG], -80No.EX-OMS0026CN [SYSTEM CONFIGURATION STATUS][Unit Name][I/O MONITOR] (EX600-DXD ) ON/OFF -81No.EX-OMS0026CN [UNIT PARAMETER] [UNIT PARAMETER] (EX600-DXD ) [SET] -82No.EX-OMS0026CN [CHANNEL PARAMETER] [CHANNEL PARAMETER] (EX600-DXD) [SET] -83No.EX-OMS0026CN [FORCE MODE] (EX600-DXD) ON ON
Allocated bytes Unit Unit part number Input Output EX600-SPN3 / 4 (32 outputs) 0 4 SI unit EX600-SPN3 / 4 (32 outputs) 4 4 (with diagnostic data) EX600-DX#B (8 inputs) 1 0 EX600-DX#C (8 inputs) 1 0 EX600-DX#C1 (8 inputs) 1 0 (with open circuit detection) Digital input unit EX600-DX#D (16 inputs) 2 0 EX600-DX#E (16 inputs) 2 0 EX600-DX#F (16 inputs) 2 0 EX600-DY#B (8 outputs) 0 1 EX600-DY#
No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End plate AXA DY#E DY#B DY#B DX#D DX#D DX#D DX#D DM#F SEN -79No.EX-OMS0027 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen. The unit which requires a diagnostics can be specified.
Clear UP to 1.5 0.08 to 0.5 (AWG28 to 20) XN2A-1430 t Replacement fuse Replacement fuse for the input unit (EX510DX) and the output unit (EX510-DY). The cable may be pulled out if the pulling force is 12 N or greater. Fuse Electrical specifications EX9-FU10 EX9-FU50 Part no.
-X Individual -X 1149 Series CM2X Basic Style (B) CM2XB Bore size Stroke G 2 x NN G H2 H1 Width across flats B2 Width across flats B1 2 x P (Rc, NPT, G) 2 x Eh8 NA D Effective thread length 2 x FL S + Stroke F A AL MM Width across flats KA NA N F H K N ZZ + Stroke Boss-cut style ZZ + Stroke (mm) H1 H G AL F A E MM P S ZZ B2 D H2 I FL K KA NA NN B1 N Bore size (mm) 0 0.033 0 0.033 0 0.033