SMC Corporation of America
Elite Part Number Search
Search Results "HRSH090-WF-20"

screw tap NT-UNC Data (in) Bore size (in) MM KK NT XA NH YE WF TN NE EA EE DD A AA B CA D E NA 075 (3/4") 10-32 UNF 0.625 0.75 1.12 0.38 0.88 0.34 0.62 0.81 0.12 1.00 1/8 1.00 0.093 0.22 1/4-28 10-32 UNF 1/4-20 0.250 106 (1 1/16") 10-32 UNF 0.750 0.75 1.47 0.62 1.22 0.47 0.81 0.24 1.12 1.25 1/8 1.25 0.093 0.25 3/16-24 10-32 UNF 1/4-20 0.312 150 (1 1/2") 1/4-20 NUC 1.00 1.25 1.93 0.88 1.57

A 8 D wf wt stAr()flf stA 33457 rEM0.llil .25 .47 .43 M l O x l .20 .85 .51 I Imm .28 stAl2Irt stA 332990Elvl.t5M .38 .71 .55 M l 2 x l .24 1.28 .0J l3mm .28 SLAltr20x.38 sta_ill33 (r.Rlorl|il.?

Description 10 20 30 50 DSeal kit P523010-20 P523020-20 P523030-20 P523040-20 No. Description Qty. No. Description Qty. No. Description Qty. No.

0.01 0.01 0.02 5 10 15 20 0 Moment ( Nm) 5 10 15 20 0 Moment ( Nm) 25 25 25 5 10 15 20 0 Moment ( Nm) CY1HT25, 32 CY1HT25, 32 CY1HT25, 32 0.05 CY1HT25 CY1HT25 CY1HT32 CY1HT25 CY1HT32 Deflection (mm) Deflection (mm) 0.03 0.04 0.02 0.03 CY1HT32 0.02 0.02 0.01 0.01 0.01 20 40 0 60 80 20 40 0 60 20 40 0 60 Moment ( Nm) Moment ( Nm) Moment ( Nm) Intermediate Stops Vertical operation 1) Intermediate

25 REAH15, 20, 25 REAH15, 20, 25 REAH15, 20 REAH15, 20 REAH25 REAH15, 20 REAH25 High Precision Guide Type REAH 0.08 Deflection (mm) Deflection (mm) Deflection (mm) Deflection (mm) 0.03 REAH25 0.02 0.06 0.02 0.04 0.01 0.01 0.02 Max.

Model number: HRR050-AN/WN-20/40The transition connector from Rc to NPT is enclosed as an accessory. For NPT piping, be sure to use this connector. Model number: HRR050-AF/WF-20/40The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.

10 1.2 12 76 34 8.1 10 50.4 60h9 61h9 28H9 9 17H9 10 6 2.5 6.5 17 8.6 14 8.5 8 34.7 70 17 18.5 10 1.2 12 84 37 10.5 10.5 53.5 65h9 67h9 32H9 12 22H9 10 4.5 3 6.5 17 8.6 14 8.5 10 39.7 80 19 21 12 1.6 15.5 100 50 12.4 12.5 60.6 75h9 77h9 35H9 13 26H9 12 5 3 7.5 20 10.5 18 10.5 (mm) JC JD JJ JU JV Q S SC SD SU UU WA WB WC WD WE WF XA XB XC YA YB YC Size 10 20 30 50 M8 x 1.25 12 M5 x 0.8 M4

The HRSH090 is a compact chiller with large cooling capacity. A 9.5kW air cooled or 11kW water cooled refrigerating method can be selected. The system is controlled with a triple inverter, offering premium energy savings. Inverter technology allows precise delivery of fan, compressor and pump performance instead of less efficient ON/OFF cycling.

The HRSH090 is a compact chiller with large cooling capacity. A 9.5kW air cooled or 11kW water cooled refrigerating method can be selected. The system is controlled with a triple inverter, offering premium energy savings. Inverter technology allows precise delivery of fan, compressor and pump performance instead of less efficient ON/OFF cycling.

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, O-Ring Set (12-90, HRSH090

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-A-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

Please contact us for the latest version.sales@ocaire.com, MAIN BOARD HRSH090-W-40, OTHERS, HRS THERMO-CHILLERS, 21, HRS - NO SIZE RATING, 2.23666 lb

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090

with the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Cooling Fan For HRSH090

grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, FRONT UPPER PANEL ASSEMBLY HRSH090

the grill of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Mechanical Seal Set HRSH090

of the front panel allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Power Terminal Cover HRS090/HRSH090