The position of spanner should be a root as close as possible to R thread. Hex. across flats may be deformed, if using an improper wrench for hex. across flats.
How to Order Type 46 (5 Port/Base mounted) Applicable solenoid valve SYJ340SYJ343SS5YJ3 46 05 M5 Type 46 Type S46 ( ) Single solenoid coil is on same side as the A,B port. M5 x 0.8 R1 R2 port Applicable blanking plate assembly SYJ3000-21-2A Stations Valve mounting direction 02 2 stations Single solenoid coil is on opposite side as the A,B port.
IC chips With adapter Single unit Nozzle 0.8, 1.1 P. 9 AN Thin Flat Pad For adsorption of soft work pieces such as thin sheets or vinyl.
Mounting pitch L (mm) Bore size (mm) 10 16 20 25 32 30 33 40 46 56 Dimensions of shielding plate (MU-S025) that is sold separately are indicated as reference.
When the piston speed exceed 750 mm/s, make sure that direct impact does not apply on the cylinder cover by using an external stopper (shock absorber, etc). Standard external (B) 17 25 35 36 46 60 70 86 100 Dimensions except mentioned above are the same as standard type.
IC chips With adapter Single unit Nozzle 0.8, 1.1 P. 9 AN Thin Flat Pad For adsorption of soft work pieces such as thin sheets or vinyl.
odd number, an even number that is one larger than this odd number is used for the calculation. 4: When n is an odd number, an even number that is one larger than this odd number is used for the calculation.
Shut off the main circuit power as soon as an alarm occurs. 2.
Equipment such as an ejector is configured as an individual unit. Thus, it is possible to create a flexible system configuration in which the circuit composition and the mounting locations can be selected as desired.
Configure an external sequence that has the timings shown as below using an external device such as the MR-J3-D05 safety logic unit of Mitsubishi Electric Corporation.
An external pilot style that can be used individually is available as a made-to-order. For details, refer to the page 4-6-46.
Dedicated grounding should be used as much as possible. Grounding should be to a type 3 ground. (Ground resistance of 100 or less.) 3. Grounding should be as close as possible to the controller, and the ground wires should be as short as possible. 4. In the unlikely event that malfunction is caused by the ground, it may be disconnected. 1. Wiring should be properly completed.
Provide an intermediate support for a cylinder with a long stroke. If the cylinder has a long stroke, provide an intermediate support to prevent the rod from sagging and the tube from flexing, as well as to prevent damage to the rod due to vibrations or external loads. Mounting Caution 1. Be sure to connect the rod and the load so that their axial center and movement directions match.
Grease pack part number: GR-S-010 Note 3) A switch spacer, as specified in the table above will be required if an auto switch is mounted afterward. When ordering an additional auto switch, also order an additional switch spacer.
When directly driving a load which generates a surge, such as a relay or solenoid valve, use a switch with a built-in surge absorbing element. 7. Cautions for use in an interlock circuit When an auto switch is used for an interlock signal requiring high reliability, devise a double interlock system to safeguard against malfunctions.
Meaning When Parameter Classification Enabled Uses the absolute encoder as an absolute encoder. n.0 [Factory setting] Pn002 After restart Setup n.1 Uses the absolute encoder as an incremental encoder.